Technical Specification
Function  Range  Accuracy
 AC Current 40.00 mA, 400.0 mA, 4000 mA
40.00 A
100.0 A 
 ±(0.8 % of reading + 3 digits)
±(1.0 % of reading + 3 digits)
± (1.2 % of reading ± 3 digits)
 AC/DC Voltage 40.0 V
400.0, 600.0V V 
±(0.5 % of reading + 4 digits)
±(0.5 % of reading + 2 digits) 
 THD 0 … 99.9 %
100 … 999 %
±(2.0 % of reading + 3 digits)
±(2.0 % of reading + 3 digits) 
 Frequency 45.0 - 500.0 Hz ± 0.5 % ±1 digit 
 Crest Factor 1.00 … 2.99
3.00 … 9.99
±(2.0 % of reading + 2 digits)
±(3.0 % of reading + 5 digits) 
 Peak Value 40.00 ... 100.0 A
40.00 V ... 600.0 V
±(3.0 % of reading + 3 digits)
±(3.0 % of reading + 3 digits 
 Power Factor (PF) 0.00 … 1.00 ± 5 digits 
 Phase -180.0° … +180.0°  ± 10 digits 
 Power (W,Var,VA) 0.000 ... 9999  ± (1% of reading ± 30 digits) 
 Power (kW,kVar,kVA) 10.00 ... 99.99 ± (2% of reading ± 30 digits) 
 General data  
 Power Supply 2 x 1.5 V batteries, type AA 
 Overvoltage Catagory CAT III / 600 V,CAT IV / 300 V  
 Dimensions 190 x 60 x 43  
Weight 255 g 

Description

Metrel MD9272 AC DC Leakage TRMS Clamp Meter

High accuracy leakage current and power measurements

 

MD 9272 is a unique earth leakage clamp meter. It not just has the ability to accurately read the TRMS AC leakage current of a system, it can also detect losses in the system and suggest possible reasons for the loss. The voltage (AC/DC), frequency, power, harmonic, power factor (PF), total harmonic distortion (THD) and crest factor measurements make this instrument suitable for any electrician and engineer.

 

MD9272 Comes Supplied With:

  • Current clamp MD 9272
  • Test lead with probe, 2 pcs
  • 1.5 V battery, type AA, 2 pcs
  • Pouch
  • Instruction manual
  • Warranty

 

Measuring Functions:

  • TRMS AC, DC voltage measurement. 
  • TRMS AC current measurement. 
  • Frequency measurement. 
  • Power parameters measurement.

 

Key Features:

  • TRMS: accurate measurements on sinusoidal and non-sinusoidal signals. 
  • Jaw size: 28 mm. 
  • Shielded Jaw: shielded jaw allows the clamp meter to be used in the noisiest environments. 
  • Accurate: readings of AC current with an accuracy of 0.8 % and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 % and a base resolution of 0.01 V. 
  • Power: measures various power parameters (active, reactive, apparent power, THD, PF, phase displacement). 
  • Intelligent loss analysis: complex algorithms detect loss and allow determining possible reasons for current loss. 
  • Harmonics: measures current or voltage harmonic components and a percentage value of a harmonic up to the 19th. 
  • THD and PF: dual display allows readings to be displayed along with Total Harmonic Distortion (THD) or Power Factor (PF). 
  • Peak value: the peak value of the waveform or crest factor can be displayed. 
  • MAX/MIN/HOLD mode: displays maximum, minimum or average measured value.

 

Sizes and Dimensions:

  • Dimensions (w x h x l): 60 x 43 x 190 mm
  • Mass (without accessories): 255 g

 

About Metrel

Metrel was established in 1957 as a factory for the production of electrical measuring instruments and components for the domestic market and grew from there to become one of world’s leading manufacturers of measuring and testing equipment. They are one of the few companies in the industry that develops and manufactures products at a single location, starting with design and ending with final assembly, quality control and calibration.

 

Features & Specification

More Information
Key Features 0.01mA Resolution, 28mm Jaw Size, Large LCD Display, Measures Harmonics, TRMS, Frequency Measurement, Earth Leakage Test
Manufacturer Metrel
Short Description
Metrel MD9272 Leakage AC/DC TRMS Clamp Meter
Technical Specification
Function  Range  Accuracy
 AC Current 40.00 mA, 400.0 mA, 4000 mA
40.00 A
100.0 A 
 ±(0.8 % of reading + 3 digits)
±(1.0 % of reading + 3 digits)
± (1.2 % of reading ± 3 digits)
 AC/DC Voltage 40.0 V
400.0, 600.0V V 
±(0.5 % of reading + 4 digits)
±(0.5 % of reading + 2 digits) 
 THD 0 … 99.9 %
100 … 999 %
±(2.0 % of reading + 3 digits)
±(2.0 % of reading + 3 digits) 
 Frequency 45.0 - 500.0 Hz ± 0.5 % ±1 digit 
 Crest Factor 1.00 … 2.99
3.00 … 9.99
±(2.0 % of reading + 2 digits)
±(3.0 % of reading + 5 digits) 
 Peak Value 40.00 ... 100.0 A
40.00 V ... 600.0 V
±(3.0 % of reading + 3 digits)
±(3.0 % of reading + 3 digits 
 Power Factor (PF) 0.00 … 1.00 ± 5 digits 
 Phase -180.0° … +180.0°  ± 10 digits 
 Power (W,Var,VA) 0.000 ... 9999  ± (1% of reading ± 30 digits) 
 Power (kW,kVar,kVA) 10.00 ... 99.99 ± (2% of reading ± 30 digits) 
 General data  
 Power Supply 2 x 1.5 V batteries, type AA 
 Overvoltage Catagory CAT III / 600 V,CAT IV / 300 V  
 Dimensions 190 x 60 x 43  
Weight 255 g 
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA