Chauvin Arnoux PEL103 Power and Energy Logger /w MA193 Clamps P01157151

£2,505.00

Chauvin Arnoux PEL103 Power and Energy Logger

Installation Types  Single Phase, Split Phase, Three Phase with or without neutral
and many other specific configurations
Number of Channels 3 voltage inputs/ 3 current inputs
calculation of neutral current
Network Frequency DC, 50Hz, 60Hz and 400Hz 
Voltage Range 10 to 1000V AC/DC/  ±0.2% + 0.5V 
Current Sensors Supported 
MN93 2 to 240A AC / ±1.2& + 1A 
MN93A 0.005A AC to 5A AC / ±1.2% + 2mA
0.1A AC to 120A AC / ±1.2% + 2mA
C193 3A to 1200A AC / ±0.5%
A193 & MA193 200mA to 10kA AC / ±1.2% + 70mA 
PAC93  10A to 1000A AC / ±1.7% + 1A
10A to 1400A AC / ±1.7% + 1A
E3N 50mA to 10A AC/DC / ±3.2% + 70mA
100mA to 100A AC/DC / ±3.2% + 70mA
Calculated Measurements 
Voltage Ratio / Current Ratio Up to 650000V / up to 25000A 
Power from 10W to 10GW / from 10 var to 10Gvar / from 10VA to 10GVA 
Energy Up to 4EWh / 4 Evarh / 4EVAh (e + 1018)
Phase Cos, tan, pf 
Harmonics Up to the 50th order 
Complementary Functions 
Phase Order
MIN/MAX
Yes
Yes
Mounting Magnet, Hook 
Recording 
Sampling / Acquisition Rate / Aggregation 128S/period - 1 measurement per second - from 1 min to 60 min 
Memory SD card (SD-HC up to 32GB) 
Communication Bluetooth (Class 2), Ethernet, USB 
Power Supply 110V to 250V (+10% - 15%) @ 50-60Hz and 400Hz 
Safety IEC 61010 600V CAT IV - 1000V CAT III 
Mechanical Specifications 
Dimensions 256 x 125 x 37mm without sensor 
Weight 900g 
Casing IP54, UL (pending)

Description

Chauvin Arnoux PEL103 Power and Energy Logger /w MA193 Clamps P01157151

Ergonomic, magnetized and suitable for all types of cabinets, PEL103 loggers provide all the power and energy measurements simultaneously. 

*Please note this unit does NOT come with the Power Adapter P01102204, this can be added by selecting it in the drop-down box above.


Optimize your energy efficiency with PEL103 Power and Energy Logger. Offering much more than simple energy metering, our PEL103 electrical measuring instrument records electrical consumption while measuring and analysing the power supplied.

Chauvin Arnoux PEL103 is Supplied With:

  • 1x carrying bag
  • 4x measurement cables (straight-banana/straight-banana 3m long - black)
  • 4x crocodile clips (black)
  • 1x set of plugs (for the extremities of the cables and current sensors)
  • 1x mains cable
  • 1x 8 GB SD card, 1 USB cable
  • 1x SD-USB adapter
  • 1x PC software (PEL Transfer)
  • x1 user’s manual (on CD)
  • 1x safety datasheet
  • 1x quick start guide.
  • 3x MA193-250 Flexi Clamps

 

Key Features:

  • Single-phase, split-phase and three-phase installations
  • Installation without cutting off the mains power supply
  • Harmonic analysis up to the 50th order
  • Bluetooth, Ethernet and USB Communication
  • Automatic recognition of the sensors connected
  • Recording on SD card
  • Real-time communication with a PC and analysis with the PEL Transfer software


Measuring The Savings:

The recordings made with PEL103 electrical measuring instrument are time and date-stamped. In this way, the gains achieved can be measured very simply by comparing the recordings before and after modifications to an installation. The analysis of the recordings made with the PEL103 before the modifications provides the period of reference. The various operations for maintenance, improvement of the electrical network and equipment, etc., can then be carried out. 
 
A correctly-positioned PEL103 will quickly help to spotlight the points where work is required, without wasting any time. A follow-up period will then enable you to determine whether the solutions implemented are sufficient and, in particular, to measure precisely the savings achieved. The PEL103 will then provide the data for comparison with the recordings from the period of reference. The DataView®analysis software can then be used to produce customized reports.
 

Predictive Maintenance:

When installed for long periods as fixed instruments in cabinets, PEL103 loggers constantly monitor all the active, apparent and reactive power values on the electrical network. Any threshold overruns can then be detected instantly.

With the DataView® software for automatic generation and printing of reports, balance sheets, graphs and summaries, users can act quickly on the cause of this overconsumption, which will lead to higher bills. Indeed, any overruns of the subscribed power will lead to higher bills.

Key Benefits:

  • 0.2 % accuracy class
  • Measurement of power indices, PF, THD, hour meter, min/max, etc.
  • Measurement of all power values
  • Measurement from DC up to 400 Hz
  • Energy measurement and costing
  • Voltage up to 1,000 V
  • Communication via Ethernet, Bluetooth and SD card
  • Simple to set up without opening the electrical network
  • Configuration in record time
  • Recording on SD card





isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.

ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.

 

Features & Specification

More Information
Key Features Bluetooth/Ethernet/USB, Kit Options Available, Analyse voltages up to 1000V AC/DC, Analyse current up to 10000 A, 8 GB SD memory card supplied, Self powering via the phase, Current up to 10 kA AC or 5 kA DC, Measurements on motors, Split phase - three phase - with or without neutral, Real-time PC communication, FREE Dataview Software (Full Version)
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Chauvin Arnoux
Short Description

Chauvin Arnoux PEL103 Power and Energy Logger

Installation Types  Single Phase, Split Phase, Three Phase with or without neutral
and many other specific configurations
Number of Channels 3 voltage inputs/ 3 current inputs
calculation of neutral current
Network Frequency DC, 50Hz, 60Hz and 400Hz 
Voltage Range 10 to 1000V AC/DC/  ±0.2% + 0.5V 
Current Sensors Supported 
MN93 2 to 240A AC / ±1.2& + 1A 
MN93A 0.005A AC to 5A AC / ±1.2% + 2mA
0.1A AC to 120A AC / ±1.2% + 2mA
C193 3A to 1200A AC / ±0.5%
A193 & MA193 200mA to 10kA AC / ±1.2% + 70mA 
PAC93  10A to 1000A AC / ±1.7% + 1A
10A to 1400A AC / ±1.7% + 1A
E3N 50mA to 10A AC/DC / ±3.2% + 70mA
100mA to 100A AC/DC / ±3.2% + 70mA
Calculated Measurements 
Voltage Ratio / Current Ratio Up to 650000V / up to 25000A 
Power from 10W to 10GW / from 10 var to 10Gvar / from 10VA to 10GVA 
Energy Up to 4EWh / 4 Evarh / 4EVAh (e + 1018)
Phase Cos, tan, pf 
Harmonics Up to the 50th order 
Complementary Functions 
Phase Order
MIN/MAX
Yes
Yes
Mounting Magnet, Hook 
Recording 
Sampling / Acquisition Rate / Aggregation 128S/period - 1 measurement per second - from 1 min to 60 min 
Memory SD card (SD-HC up to 32GB) 
Communication Bluetooth (Class 2), Ethernet, USB 
Power Supply 110V to 250V (+10% - 15%) @ 50-60Hz and 400Hz 
Safety IEC 61010 600V CAT IV - 1000V CAT III 
Mechanical Specifications 
Dimensions 256 x 125 x 37mm without sensor 
Weight 900g 
Casing IP54, UL (pending)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA