Chauvin Arnoux F201 1000V TRMS Clamp Meter P01120921

£202.80
Chauvin Arnoux F201 Clamp Meter Specification
Clamping Diameter 34mm
Display LCD
Resolution 6000 counts
Number of Values Displayed 1
Type of Acquisition TRMS (AC)
Autorange Yes
AC Current  
AC Current Range 0.15 to 600A (900A peak)
Best Accuracy 1% reading + 3 cts
Frequency  
Range Current: 5.0 to 3000Hz
Voltage: 5.0 to 20.00kHz
Resistance  
Range 0.1 to 59.99kΩ
Open Circuit Voltage ≤8V
Measurement Current ≤680μA
Audible Continuity  
Continuity Threshold Adjustable from 1 to 599
Diode Test Yes
Temperature  
Range -60.0 to 1000°C (-76.0 to 1832°F)

Description

Chauvin Arnoux F201 1000V TRMS Clamp Meter

A specially priced 1000V AC/DC 600A AC Clamp Meter from Chauvin Arnoux


The F200 clamps are ideal for low-power or medium-power low-voltage applications: maintenance of tertiary or industrial electrical installations or installed machines, power supply diagnostics and/or sizing, commissioning of air-conditioning and heating systems, work on electric vehicles, etc.

The F201 clamp is ideal for the needs of both self-employed electricians and SME contractors in the electrical sector.
Equipped with a fast 12-bit TRMS digital acquisition system, F201 clamps offer particularly accurate measurements whatever the signal's waveform.


F201 TRMS Clamp Comes Supplied With:

  • Chauvin Arnoux F201 AC Clamp Meter
  • Set of Test Leads
  • Type K Thermocouple Probe
  • 9V Battery
  • Carrying Pouch
  • Startup Guide and Operating Manual (on CD-ROM)


Key Features:

  • TRMS
  • Clamping diameter: 34 mm
  • Rated IP54 
  • Current: 600 A AC
  • AC and DC voltage up to 1,000 V
  • Resistance and audible continuity
  • Temperature
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX
  • CAT IV 600 V


True inrush Function

The True Inrush function makes it easy to analyse both the inrush of a single motor and the inrush of a set of machines in operation. The clamp automatically determines the type of signal and the level of current in the installation and then adapts the algorithm and measurement mode to capture the expected overcurrent.

Indeed, correct sizing of electrical installations in terms of both the conductors and the protective systems implemented is a recurrent problem. Overcurrents usually occur when an installation or a machine is started up or when machinery is subjected to heavy loads. The True Inrush function enables you to size the installation correctly.


TRMS Version of Min and Max!

The Min and Max are TRMS values calculated throughout up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.

Peak+ and Peak-

Calculated throughout 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation’s behaviour or even malfunctions.

THD and Harmonics

When seeking the causes of a malfunction, knowledge of the overall signal distortion (THDr or THDf) or frequential distortion (harmonic analysis) helps you to identify the precise corrective solution required: filtering, oversizing, etc. Harmonic analysis also contributes to fire prevention.

∆REL, for Quick Evaluation

Comparison with a reference quantity is a quick way of evaluating and analysing your results. A signal’s variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ∆REL function can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions.

Safety

1,000 V CAT IV, an unprecedented level of safety for clamp multimeters! Users can be sure of working in total safety and in compliance with the applicable standards. The instruments’ IP54 protection safeguards them against dust, in particular, thus guaranteeing that safety is maintained over time. The mechanical design of these clamps enables them to pass the standard test for falls from a height of 2 metres.

isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.

Features & Specification

More Information
Key Features 1000 V CAT IV, Automatic AC / DC detection, RELative and diff erential measurements, Resistance/audible continuity, Resolution 6000 counts, Temperature (°C / °F) , Voltage 1000 V AC/DC, TRMS
Manufacturer Chauvin Arnoux
Short Description
Chauvin Arnoux F201 Clamp Meter Specification
Clamping Diameter 34mm
Display LCD
Resolution 6000 counts
Number of Values Displayed 1
Type of Acquisition TRMS (AC)
Autorange Yes
AC Current  
AC Current Range 0.15 to 600A (900A peak)
Best Accuracy 1% reading + 3 cts
Frequency  
Range Current: 5.0 to 3000Hz
Voltage: 5.0 to 20.00kHz
Resistance  
Range 0.1 to 59.99kΩ
Open Circuit Voltage ≤8V
Measurement Current ≤680μA
Audible Continuity  
Continuity Threshold Adjustable from 1 to 599
Diode Test Yes
Temperature  
Range -60.0 to 1000°C (-76.0 to 1832°F)
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA