Technical Specification | CA8331 | CA8333 | CA8336 | CA8436 |
Number of Channels | 3U / 4I | 4U / 4I | ||
Number of Inputs | 4V / 3I | 5V 4I | ||
Voltage (TRMS AC+DC) | 2V to 1,000V | |||
Voltage Ratio | Up to 500kV | |||
Current (TRMS AC+DC) MN Clamps | MN93: 500 mA to 200 Aac; MN93A: 0.005 Aac to 100 Aac | |||
C193 Clamp | 1 A to 1,000 Aac | |||
AmpFlex® or MiniFlex® clamps | 100 mA to 10,000 Aac | |||
PAC93 Clamp | 1 A to 1,300 Aac/dc | |||
E3N Clamp | 50 mA to 100 Aac/dc | |||
J93 | 50 A to 3,500 Aac / 5,000 Adc | |||
Current Ratio | up to 60 kA | |||
Frequency | 40 Hz to 69 Hz | |||
Power Values | W, VA, var, VAD, PF, DPF, cos φ, tan φ | |||
Energy Values | Wh, varh, VAh, VADh | |||
Harmonics | Yes | |||
THD | yes, orders 0 to 50, phase | |||
Expert Mode | - | Yes | ||
Transients | - | 50 | 210 | |
Flicker Pst | Yes | |||
Plt | - | - | Yes | |
Inrush Mode | - | Yes on 4 periods | Yes> 10 minutes | |
Unbalance yes | Yes | |||
Recording Min/Max | Yes | |||
of a selection of parameters at the Max sampling rate. | 4 hours to 2 weeks | Few days to several weeks | 2 weeks to several years | |
Alarms | - | 4,000 of 10 different types | 10,000 of 40 different types | |
Peak | Yes | |||
Vectorial representation | Automatic | |||
Display | Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm | |||
Capture of screens and curves | 12 | 50 | ||
Electrical safety | IEC 61010 1,000 V CAT III / 600 V CAT IV | |||
Protection | IP53 / IK08 | IP67 | ||
Languages | More than 27 | |||
Communication interface | USB | |||
Battery life | Up to 13 hours | |||
Power supply | 9.6 V NiMH rechargeable battery or external mains charger | |||
Dimensions | 240 x 180 x 55mm | 270x250x180mm | ||
Weight | 1.9Kg | 3.7Kg |
Description
Chauvin Arnoux CA8333 Qualistar Plus Power Analyser
Measure all the necessary voltage, current and power parameters for full diagnosis of an electrical installation. Capture and record all the parameters, transients, alarms and wave forms simultaneously.
Designed for inspection and maintenance teams in industrial or administrative buildings, the Qualistar can provide a snapshot of the main electrical network quality characteristics. Easy to handle and precise, these instruments also offer a large number of calculated values and several processing functions.
Designed to cover all 600 V CAT IV and 1000 V CAT III applications in compliance with the IEC 61010 standard, the Qualistar+ range is divided up according to the functions provided and the connections available:
- C.A 8331 & C.A 8333: 4 voltage inputs and 3 current inputs,t,
- C.A 8336 & C.A 8435: 5 voltage inputs and 4 current inputs.
The whole range benefits from a set of inserts and rings for customizing the colour-coding in each country. Equipped with IP67 connections to ensure water-proofing, the C.A 8435 is also compatible with all the existing Qualistar measuring accessories.
key Features:
- Real-time display of wave forms (4 voltages and 4 currents)
- Half-period RMS measurements of voltages and currents
- Intuitive use
- Automatic recognition of the different types of current sensors
- Measurement on any type of installation: three-phase, Aron, etc.
- Integration of all the DC components
- Measurement, calculation and display of harmonics up to the 50th order,
- Display of phasor diagram
- Measurement of P, Q, S and D power values (total and per phase)
- Energy measurement (total and per phase)
- Calculation of the K Factor & FHL
- Calculation of distorting voltages and currents
- Calculation of the cos φ displacement power factor (DPF) and the power factor (PF)
- Inrush over up to 10 minutes
- Capture of hundreds of transients lasting several tens of µs
- Calculation of Pst & Plt flicker values
- Unbalance calculation (current and voltage)
- Monitoring of the electrical network with setting of alarms
- IEC 61000-4-30 Class B
- Back-up and recording of screenshots (image and data)
- Recording and export on PC
- Software for data recovery and real-time communication with a PC
Connections:
The Qualistar models are ideal for applications on all types of electrical networks, from the simplest to the most complex:
- Single-phase, split-phase and three-phase with or without neutral
- All types of 2, 3, 4 and 5-wire electrical networks
- 2-wattmeters method
- ARON
- 2 ½ elements
Qualistar Power Analyser Selection Chart:
Chauvin Arnoux Power and Energy quality Analysers CA8331/CA8333/CA8336/CA8436 | ||||
Technical Specification | CA8331 | CA8333 | CA8336 | CA8436 |
Number of Channels | 3U / 4I | 4U / 4I | ||
Number of Inputs | 4V / 3I | 5V 4I | ||
Voltage (TRMS AC+DC) | 2V to 1,000V | |||
Voltage Ratio | Up to 500kV | |||
Current (TRMS AC+DC) MN Clamps | MN93: 500 mA to 200 Aac; MN93A: 0.005 Aac to 100 Aac | |||
C193 Clamp | 1 A to 1,000 Aac | |||
AmpFlex® or MiniFlex® clamps | 100 mA to 10,000 Aac | |||
PAC93 Clamp | 1 A to 1,300 Aac/dc | |||
E3N Clamp | 50 mA to 100 Aac/dc | |||
J93 | 50 A to 3,500 Aac / 5,000 Adc | |||
Current Ratio | up to 60 kA | |||
Frequency | 40 Hz to 69 Hz | |||
Power Values | W, VA, var, VAD, PF, DPF, cos φ, tan φ | |||
Energy Values | Wh, varh, VAh, VADh | |||
Harmonics | Yes | |||
THD | yes, orders 0 to 50, phase | |||
Expert Mode | - | Yes | ||
Transients | - | 50 | 210 | |
Flicker Pst | Yes | |||
Plt | - | - | Yes | |
Inrush Mode | - | Yes on 4 periods | Yes> 10 minutes | |
Unbalance yes | Yes | |||
Recording Min/Max | Yes | |||
of a selection of parameters at the Max sampling rate. | 4 hours to 2 weeks | Few days to several weeks | 2 weeks to several years | |
Alarms | - | 4,000 of 10 different types | 10,000 of 40 different types | |
Peak | Yes | |||
Vectorial representation | Automatic | |||
Display | Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm | |||
Capture of screens and curves | 12 | 50 | ||
Electrical safety | IEC 61010 1,000 V CAT III / 600 V CAT IV | |||
Protection | IP53 / IK08 | IP67 | ||
Languages | More than 27 | |||
Communication interface | USB | |||
Battery life | Up to 13 hours | |||
Power supply | 9.6 V NiMH rechargeable battery or external mains charger | |||
Dimensions | 240 x 180 x 55mm | 270x250x180mm | ||
Weight | 1.9Kg | 3.7Kg |
Spares & Accssories (Not Included):
Reeling Box P01102149
Magnetised Voltage Probes P01103058Z
ESSAILEC connexion kit Adapter P01102131
CA833* Kit carry case, no22 P01298056
CA833* Instrument carry case, no21 P01298055
CA833* Lead carry case, no6 P01298051
PA30W, Mains power supply P01102057
Features & Specification
Key Features | Multiple Connectivity Options, Single Phase, Three Phase, Data Logging, AC/DC Current, Simple Operation, Meter and Sequence Modes, Highly Accurate | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Chauvin Arnoux | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA