Chauvin Arnoux CA6117 High-performance Multifunction Tester P01145460X

£1,738.80
Chauvin Arnoux CA 6117 Multifunction Tester Technical Specification
CONTINUITY / RESISTANCE  
I rated / Range / Resolution I > 200 mA / 39.99 Ω/ 0.01Ω / ± (1.5 % of measurement + 2 cts)
12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω /± (1.5 % of measurement + 5 cts) with beep
Range / Resolution / Accuracy 4 kΩ/ 1 Ω / ±(1.5 % of measurement + 5 cts) 40 kΩ - 400 kΩ/ 10 Ω - 100 Ω / ±(1.5 % of measurement + 2 cts)
INSULATION
Rated voltage Utest: 50 /100 / 250 / 500 / 1,000 VDC
Range / Resolution / Accuracy 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5 % of measurement + 3 cts)
Short-circuit current ≤ 3 mA
EARTH
3P EARTH
Range / Resolution / Accuracy
0.50 Ω to 40 Ω/ 0.01 Ω / ±(2 % of measurement + 10 cts) 40 Ω to 15 kΩ / 0.1 Ω to 1 Ω / ±(2 % of measurement + 2 cts)
15 kΩ to 40 kΩ / 10 Ω/ ±(10 % of measurement + 2 cts )
Others Measurement of resistance of auxiliary stakes RH & RS (up to 40 kΩ)
Ufk Complies with SEV 3569
1P SELECTIVE EARTH
Range / Resolution / Accuracy
0.20 Ω to 39.99 Ω - 40 Ω to 399.9 Ω / 0.01 Ω – 0.1 Ω / ±(10 % of measurement + 10 cts) (ISel via clamp)
LOOP IMPEDANCE (Zs (L-PE) and Zi (L-N or L-L)) – 1P LIVE EARTH
LIVE EARTH
Installation voltage / Freq.
90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz
High-current mode with TRIP Zs (L-PE) & Zi (L-N or L-L)
Range / Resolution / Accuracy
Max. test current: 7.5 A
(0.050) 0.100 Ω to 0.5 Ω / 0.001 Ω/ ±(10 % of measurement + 20 cts) • 0.5 Ω to 3.999 Ω / 0.001 Ω/ ±(5 % of measurement
+ 20 cts) 3.999 to 39.99 Ω/ 0.01Ω / ±(5 % of measurement + 2 cts) • 39.99 Ω to 399.99 Ω / 0.1 Ω/ ±(5 % of measurement + 2 cts)
NO TRIP mode (Zs (L-PE) only) Test current: 6 mA – 9 mA – 12 mA (as required) 0.20 Ω to 0.99 Ω / 0.01 Ω / ±(15 % of measurement + 10 cts)
1.00 to 1.99 Ω / 0.01 Ω / ±(15 % of measurement + 3 cts) 2.00 to 39.99 Ω / 0.01 Ω / ±(10 % of measurement + 3 cts)
40.00 Ω to 399.9 Ω / 0.1 Ω / ±(5 % of measurement + 2 cts) 400 to 3999 Ω / 1 Ω / ±(5 % of measurement + 2 cts)
Calculation of Ik short-circuit current
(PFC (Zs), I Sc PSCC (Zi)
Fault current and short-circuit current: 0.1 A to 20 kA
Integrated fuse table Yes
Voltage drop ∆V%(Zi) -40 % to +40 %
Others Measurement of the resistive and inductive components of the Zs and Zi impedances
AC, A and F-type RCDs
Installation voltage / Frequency 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
I∆n 6*/10/30/100/300/500/650/1,000 mA (90 V – 280 V) or 6*/10/30/100/300/500 mA (280-550 V) or variable Ramp and pulse test
No-trip test at ½ I∆n – Duration: 1,000 ms or 2,000 ms
Ramp mode 0.2 to 0.5 x I∆n (Uf ) / 0.3 x I∆n to 1.06 x I∆n in increments of 3.3 % x I∆n
Trip time measurement:
Range / Resolution / Accuracy
0.2 to 0.5 x I∆n (Uf ) / 0.5 x I∆n / 2 x I∆n (selective) / 5 x I∆n
Pulse: 0 to 500 ms / 0.1 and 1 ms / 2 ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms
B, B+ and EV-type RCDs
Installation voltage / Frequency 90 V to 280 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
Test in ramp mode: I∆n 6/10/30/100/300/500 mA
or variable 6-499 mA
Test in ramp mode 0.2 x I∆N to 2.2 x I∆n
Test in pulse mode at 2 x I∆n: I∆n 6/10/30/100/ 300 mA or variable ≤ 250 mA
2.2 x 2 x I∆N
Test in pulse mode at 4 x I∆n: I∆n 6/10/30/100 mA or variable ≤ 125 mA
2.4 x 4 x I∆N
OTHER MEASUREMENTS
Current by clamps C177/C177A (0.5 mA**) 5 mA to 19.99 A (C177) /
20 mA to 199.9 A (C177A)
5.0 mA to 199.9 A (C177A)
Current by clamp MN77 (1 mA**) 5.0 mA to 19.99 A
Voltage 0 to 550 VAC/DC / DC  and 15.8 to 500 Hz
Frequency 10 to 500 Hz
Phase rotation 20 to 500 VAC
Active power 0 to 110 kW single-phase - 0 to 330 kW three-phase
Simultaneous display of voltage and current waveforms
Harmonics Voltage and current / up to 50th order / THD-F /THD-R
GENERAL SPECIFICATIONS
Display Large 5.7” backlit graphic colour LCD screen, 320 x 240 points
Storage/Communication via USB for data transfer and report creation
Power supply: rechargeable battery NiMH 9.6 V rated 4 Ah
Lithium-ion 10.8 V rated 5.8 Ah
Battery life up to 24 hours
up to 30 hours
Dimensions / weight 280 x 190 x 128 mm / 2.2 kg
Protection IP 53 / IK04
EMC IEC 61326-1
Electrical safety IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557
NEW

Description

Chauvin Arnoux CA6117 High-performance Multifunction Tester P01145460X

The CA 6117 is an ALL-IN-ONE instrument for testing electrical installations in compliance with national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc) -AC, A, F, B, B+, EV and RCD testing.
It combines design, ergonomics, simplicity, performance, rapidity and accuracy.
Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.

 

 

 

 

 

Boasting an unrivalled set of features the CA6117 is a multifunction tester capable of live 1P live-circuit earth measurement, 3P earth measurement and 1P power analysis. Please see the comprehensive documentation available in the resources tab above for more information or give us a call FREE on 0800 0224 060

*Important Calibration Information: 

This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application. 
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required. 

CA6117 Comes Supplied With:

• 1x CA6117 multifunction tester with heavy-duty nylon carrying bag
• 1x type-2 mains power pack /charger
• 1x Li-Ion battery pack
• 1x USB A/B cable, 1.80 m, with ferrite
• 1x three-point cable - 3 safety leads (red, blue and green)
• 3x test probes, Ø 4 mm (red, blue and green)
• 3x crocodile clips (red, blue and green)
• 2x elbowed-straight safety leads 3 m (red and black)
• 1x three-point Euro mains cable
• 1x 2P EURO mains cable
• 1x remote-control probe
• 1x wrist strap
• 1x 4-point hands-free strap
• ICT data export software on CD-ROM (Dataview FULL version)
• 6x operating manuals on CD (one per language)
• 1x safety datasheet

Key Features:

  • Premium 17 in 1 Multifunction Tester
  • Advanced features including power quality.
  • High build quality, ruggedness and reliability
  • Simple and intuitive operation
  • Large 5.7” backlit colour display
  • RCD Test AC, A , F, B, B+ and EV residual current devices.
  • Ultra accurate Zs test to 3 decimal places
  • Measures Power, Power Factor, and THD
  • Measurement of harmonics to 50th Order*
  • 3-wire earth resistance measurement*
  • Lithium Iron rechargeable battery.
  • *optional accessories are required for some tests 

Ergonomics:

The rugged, compact CA 6117 is specially designed for quick and effective familiarization. On its large LCD graphical colour display with backlighting, users can view all the crucial results at a glance.

A rotary switch on the instrument’s front panel gives direct access to all the functions. A large number of visual symbols and audio signals help with quick interpretation of the results in accordance with the standards. The on-line contextual help menus can guide the user step by step, if needed. The storage capacity can save up to 1,000 tests. The CA 6117 also has a USB output for data transfer.

Effective Contextual Help:

Guaranteed Safety:

The testers are equipped with a clear, detailed contextual help function.
This makes them ideal for both experts and less experienced users. Dedicated help is available for each measurement, including a guide for
the connections required and assistance for interpretation of the results. For greater safety, the instrument displays an error message to warn users if the tester is incorrectly connected or if a hazardous voltage is present.

Measurements:

The high-performance CA 6117 offers excellent measurement stability, even in disturbed industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, earth and selective earth, loop impedances, type A and AC RCDs. The CA 6117 can also be used to measure voltage, frequency, current via a clamp, active power, harmonics and phase rotation.

The CA 6117 is also fitted with type-B RCD testing, built-in fuse table and voltage-drop feature.
Designed and manufactured in France, the CA 6117 was developed in compliance with eco-design procedures.

3P Earth Measurement

The dedicated Chauvin Arnoux 3P earth kit can be purchased from the drop-down selection above for a specially discounted rate when you buy the CA6117 Multifunction tester.

Correct earthing guarantees user safety and also protects property and installations in the event of lightning or fault currents. It must always be linked to a cut-off device.
There are many different methods for earth measurements and choice of the right one depends on the type of neutral system, the type of installation (domestic, industrial, urban, rural, etc.) and the possibility of cutting off the power supply.
3-pole earth measurement using 2 auxiliary stakes (also known as the 62 % method) is the earth measurement of reference which yields a precise resistance value for the earth electrode. As it is performed with the power off, this is the only earth measurement possible on an installation which has not yet been hooked up to the electrical power distribution network or which is no longer connected to it.
Once the cables have been connected, implementation is particularly simple. All you have to do is set the rotary switch to RE 3P, press test and read off the result. Users can choose the test mode: quick or expert. In expert mode, the resistance values of the auxiliary stakes RS and RH are also measured.

       

Harmonics:

The tester can measure harmonics up to the 50th order and displays the graph.
The THD-F, THD-R and voltage values are displayed simultaneously, along with the name of the line selected and its amplitude.
In this mode, users can choose between FFT analysis of the voltage or the current and display with a linear or logarithmic scale.

Phase Rotation:

On a three-phase network, this measurement can be used to check the phase sequence on the network.
The tester checks the frequency of the 3 signals and then compares them to detect their sequence (negative or positive).

Power Analyser Mode:

The dedicated Chauvin Arnoux C177A power analyser clamp can be purchased from the drop-down selection above for a specially discounted rate when you buy the CA6117 Multifunction tester.

In the modern workplace electricians must deal with an array of complex array of work and equipment, by having high spec equipment , such as the CA6117 multi-function tester,  they can be prepared for every eventuality encountered. Many MFTs prove sufficient for basic safety testing, but when it comes to fault finding, commissioning and diagnostics,  advanced MFTs like the CA6117 come into their own by providing everything the modern electrician needs in one product.

 The CA6117 can display voltage, and, by using the optional current clamp, current waveforms while also displaying both peak (max) and RMS values. This proves useful in identifying any waveform distortion, possibly from harmonics or other sources. Power can also be displayed with direction indication for imported or exported power, ideal where microgeneration such as PV systems are present. Power Factor can be measured and seen on the graphical display. These features are essential for those working in modern electrical systems with capacitive, inductive and non-linear loads present. The ability to see these values in real-time assists in quickly diagnosing issues within the installation or supply. They are also essential when configuring or testing equipment such as power factor correction capacitor banks.

Using the voltage input and optional current clamp, the CA6117 has the ability to accurately measure and display Voltage and Current Harmonics up to the 50th harmonic order, performance typically only seen on dedicated power quality analysers or loggers. All modern electrical installations contain non-linear loads which generate harmonics.
These harmonics can cause many issues within installations, such as the overheating and premature failure of equipment. The only way to identify the underlying cause of these issues is by using a meter such as the CA6117 or an expensive power quality analyser or logger. The CA6117 has the ability to display Total Harmonic Distortion (THD), a simple measure of the amount of harmonics present. It can also show each of the 50 individual harmonics in graphical or numerical form. This powerful feature allows the electrician to identify specific harmonic issues and also check the effectiveness of harmonic mitigation measures, such as active harmonic filters.

 

A stand-out feature of the CA 6117 is its ultra-accurate Earth Fault Loop Impedance (Zs) measurement capability. Unlike most MFTs on the market, the CA 6117 is able to measure Zs to three decimal places and test lead resistance can also be nulled in Zs mode. In heavy duty installations or where working on installations close to the supply transformer, Zs values can be very low. To measure such low values, which are beyony the meaningful range of most MFTs, electricians may have to buy a expensive specialist stand-alone loop tester, but not with the CA 6117 which can measure these values using its normal high current Zs range.

Analysis of the results:

The measurements made with the CA 6117 can be processed by the DataView® multi-product expert processing software. DataView® automatically recognizes the instrument when it is connected to the PC and opens the corresponding menu. By means of a tree structure, it offers users direct access to the data recorded in the instrument, its configuration, etc.

It is equipped with multiple predefined report templates which comply with the standards' requirements.
Users can also create their own templates, as required.

Delivered as standard, the ICT software offers the following functions for quick, simplified analysis of the recorded measurements: recovery of the data, configuration of the instrument, customization of measurement campaigns with transfer into the instrument and generation of reports.

ICT

This specific software for the installation testers can be used for quick, simplified analysis of the measurements recorded by the CA 6117 tester. It is part of the standard delivery and offers the following functions:

• Data recovery
• Instrument parameter settings
• Customization of measurement sessions with transfer into the instrument
• Printing of first-level reports

The menu presents the tree structure of the data present in the product and measurement campaigns, clearly identified (customer, location, type of measurements, etc).

DataView®
(FREE Full-version for Microsoft Windows supplied with this purchase)

The measurements made can also be processed by the DataView® multi-product expert software.
DataView® automatically recognizes the instrument when it is connected to the PC and opens the corresponding menu.
This menu, displayed as a tree structure, gives users direct access to the data recorded in the instrument, its confi guration, etc.
DataView® contains multiple predefined report templates for quick printing in compliance with the applicable standards. Users can also create their own templates to meet their specific requirements.

Additional Accessories (Not Included):

Chauvin Arnoux Earth Test Kit 3P 50m P01102021

The Earth Kit is used with earth and resistivity testers implementing the 3P loop method. 

P01101021 3P Earth Kit comprises:

  • 3x Different-coloured reels red, blue, green of cables 50 m
  • 1 Mallet
  • 5x Spade lug/banana plug adapters
  • 1x Carrying bag
  • 2x Stakes

This Chauvin Arnoux earth and earth & resistivity kit is ideal for resistance measurement of normative earth rod on powered-down installations using 2 auxiliary rods (by 62% method).

It is offered also as an ideal accessory to the Chauvin Arnoux CA6117 high-performance multifunction tester.

Overview:

User Friendly

Simple connections
The colours of the cables are identical to the colours of the connecting terminals of all of our instruments, so no mistakes are possible! The cable lengths are perfectly matched to the applications for which our kits are intended.
Easy to use
For a firm grip during installation, there are handles on the coils of cable. The handles can be removed to facilitate storage.
Universal
Our kits are compatible with all of our instruments, no matter which types of connectors they use, thanks to the 4 mm Ø. banana jack/fork plug adapters provided.
Compact
The carrying bags provided are designed to facilitate storage and transport of the accessories in separate
compartments.

Earth Resistance Measurement:

Our earth kits are used to measure the resistance of existing earth probes by the 3P method (2 auxiliary
rods) E.g.: measurement of earth resistance RE by the “62 %” method.

 

isswww and Chauvin Arnoux 

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond. 

isswww and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over. 

Features & Specification

More Information
Key Features Phase-rotation testing, Intuative contextual help menus, Complies with national and international standards, Suitable for all neutral systems (TT/TN/IT), Store up to 1000 tests, USB data output connection, Voltage/current clamp/power/waveforms/harmonics, AC/A/F/B/B+/EV RCD Testing, Live-circuit earth measurement
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Chauvin Arnoux
Short Description
Chauvin Arnoux CA 6117 Multifunction Tester Technical Specification
CONTINUITY / RESISTANCE  
I rated / Range / Resolution I > 200 mA / 39.99 Ω/ 0.01Ω / ± (1.5 % of measurement + 2 cts)
12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω /± (1.5 % of measurement + 5 cts) with beep
Range / Resolution / Accuracy 4 kΩ/ 1 Ω / ±(1.5 % of measurement + 5 cts) 40 kΩ - 400 kΩ/ 10 Ω - 100 Ω / ±(1.5 % of measurement + 2 cts)
INSULATION
Rated voltage Utest: 50 /100 / 250 / 500 / 1,000 VDC
Range / Resolution / Accuracy 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5 % of measurement + 3 cts)
Short-circuit current ≤ 3 mA
EARTH
3P EARTH
Range / Resolution / Accuracy
0.50 Ω to 40 Ω/ 0.01 Ω / ±(2 % of measurement + 10 cts) 40 Ω to 15 kΩ / 0.1 Ω to 1 Ω / ±(2 % of measurement + 2 cts)
15 kΩ to 40 kΩ / 10 Ω/ ±(10 % of measurement + 2 cts )
Others Measurement of resistance of auxiliary stakes RH & RS (up to 40 kΩ)
Ufk Complies with SEV 3569
1P SELECTIVE EARTH
Range / Resolution / Accuracy
0.20 Ω to 39.99 Ω - 40 Ω to 399.9 Ω / 0.01 Ω – 0.1 Ω / ±(10 % of measurement + 10 cts) (ISel via clamp)
LOOP IMPEDANCE (Zs (L-PE) and Zi (L-N or L-L)) – 1P LIVE EARTH
LIVE EARTH
Installation voltage / Freq.
90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz
High-current mode with TRIP Zs (L-PE) & Zi (L-N or L-L)
Range / Resolution / Accuracy
Max. test current: 7.5 A
(0.050) 0.100 Ω to 0.5 Ω / 0.001 Ω/ ±(10 % of measurement + 20 cts) • 0.5 Ω to 3.999 Ω / 0.001 Ω/ ±(5 % of measurement
+ 20 cts) 3.999 to 39.99 Ω/ 0.01Ω / ±(5 % of measurement + 2 cts) • 39.99 Ω to 399.99 Ω / 0.1 Ω/ ±(5 % of measurement + 2 cts)
NO TRIP mode (Zs (L-PE) only) Test current: 6 mA – 9 mA – 12 mA (as required) 0.20 Ω to 0.99 Ω / 0.01 Ω / ±(15 % of measurement + 10 cts)
1.00 to 1.99 Ω / 0.01 Ω / ±(15 % of measurement + 3 cts) 2.00 to 39.99 Ω / 0.01 Ω / ±(10 % of measurement + 3 cts)
40.00 Ω to 399.9 Ω / 0.1 Ω / ±(5 % of measurement + 2 cts) 400 to 3999 Ω / 1 Ω / ±(5 % of measurement + 2 cts)
Calculation of Ik short-circuit current
(PFC (Zs), I Sc PSCC (Zi)
Fault current and short-circuit current: 0.1 A to 20 kA
Integrated fuse table Yes
Voltage drop ∆V%(Zi) -40 % to +40 %
Others Measurement of the resistive and inductive components of the Zs and Zi impedances
AC, A and F-type RCDs
Installation voltage / Frequency 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
I∆n 6*/10/30/100/300/500/650/1,000 mA (90 V – 280 V) or 6*/10/30/100/300/500 mA (280-550 V) or variable Ramp and pulse test
No-trip test at ½ I∆n – Duration: 1,000 ms or 2,000 ms
Ramp mode 0.2 to 0.5 x I∆n (Uf ) / 0.3 x I∆n to 1.06 x I∆n in increments of 3.3 % x I∆n
Trip time measurement:
Range / Resolution / Accuracy
0.2 to 0.5 x I∆n (Uf ) / 0.5 x I∆n / 2 x I∆n (selective) / 5 x I∆n
Pulse: 0 to 500 ms / 0.1 and 1 ms / 2 ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms
B, B+ and EV-type RCDs
Installation voltage / Frequency 90 V to 280 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz
Test in ramp mode: I∆n 6/10/30/100/300/500 mA
or variable 6-499 mA
Test in ramp mode 0.2 x I∆N to 2.2 x I∆n
Test in pulse mode at 2 x I∆n: I∆n 6/10/30/100/ 300 mA or variable ≤ 250 mA
2.2 x 2 x I∆N
Test in pulse mode at 4 x I∆n: I∆n 6/10/30/100 mA or variable ≤ 125 mA
2.4 x 4 x I∆N
OTHER MEASUREMENTS
Current by clamps C177/C177A (0.5 mA**) 5 mA to 19.99 A (C177) /
20 mA to 199.9 A (C177A)
5.0 mA to 199.9 A (C177A)
Current by clamp MN77 (1 mA**) 5.0 mA to 19.99 A
Voltage 0 to 550 VAC/DC / DC  and 15.8 to 500 Hz
Frequency 10 to 500 Hz
Phase rotation 20 to 500 VAC
Active power 0 to 110 kW single-phase - 0 to 330 kW three-phase
Simultaneous display of voltage and current waveforms
Harmonics Voltage and current / up to 50th order / THD-F /THD-R
GENERAL SPECIFICATIONS
Display Large 5.7” backlit graphic colour LCD screen, 320 x 240 points
Storage/Communication via USB for data transfer and report creation
Power supply: rechargeable battery NiMH 9.6 V rated 4 Ah
Lithium-ion 10.8 V rated 5.8 Ah
Battery life up to 24 hours
up to 30 hours
Dimensions / weight 280 x 190 x 128 mm / 2.2 kg
Protection IP 53 / IK04
EMC IEC 61326-1
Electrical safety IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA