Chauvin Arnoux CA773 Voltage Absence Tester P01191773

£179.94

Chauvin Arnoux CA 771 & CA 773 Technical Specification
Technical Specifications CA771 CA773
Display LEDs LEDs + backlit digital display
Voltage absence testing (VAT)
Voltage

12 Vac ≤ U ≤ 1,000 Vac 12 Vdc ≤ U ≤ 1,400 Vdc

1.0 V to 299.0 Vac/dc

300 V to 1,000 Vac / 1,400 Vdc

Frequency DC, 162/3 to 800 Hz
Impedance > 500 kΩ
Max. peak current 3.5 mA RMS
Polarity indication Yes
Redundant hazardous-voltage indication The ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage) with the rate at which it flashes proportional to the voltage level
Stray voltage detection Yes (by low-impedance load switching)
RCD tripping Yes (by low-impedance load switching) (approx. 30 mA at 230 V)
Phase/Neutral identification

Above 50 V (45 - 65 Hz)

Above 150 V (162/3 - 45 Hz)

Continuity & Resistance
Buzzer trigger threshold 100 Ω typical (150 Ω max.)
Extended continuity test (resistance) 2 kΩ, 60 kΩ, 300 kΩ 0.5 Ω to 2,999 kΩ
Test current / Open-circuit voltage ≤ 1 mA / ≤ 3.3 V
Phase rotation 2-wire method with microprocessor
Ph/Ph voltage 50 V ≤ U ≤ 1,000 Vac (45 - 400 Hz)
Buzzer

Intermittent beep for Voltage Detection

Continuous beep for continuity

Standards and electrical safety IEC 61243-3:2009, EN 61243-3:2010, IEC 61010 1,000 V CAT IV
Enclosure protection IP65
Climatic conditions -30 °C to +60 °C (Class S) -15 °C to +45 °C (Class N)
Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements
Dimensions / weight 228 x 60 x 39 mm (without test probes) / 350 g approx.

Chauvin Arnoux CA 771 & CA 773 Technical Specification Key Differences
Technical Specifications CA771 CA773
Display LEDs LEDs + backlit digital display
Voltage

12 Vac ≤ U ≤ 1,000 Vac 12 Vdc ≤ U ≤ 1,400 Vdc

1.0 V to 299.0 Vac/dc

300 V to 1,000 Vac / 1,400 Vdc

Extended continuity test (resistance) 2 kΩ, 60 kΩ, 300 kΩ 0.5 Ω to 2,999 kΩ
Climatic conditions -30 °C to +60 °C (Class S) -15 °C to +45 °C (Class N)
Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements

Description

Chauvin Arnoux CA773 Voltage Absence Tester P01191773

The ultimate 2-pole tester

Voltage Absence Testing: a clearly-defined procedure

In the context of work on installations connected to the electricity distribution network, the standards stipulate that the measurements must be performed with the power off to avoid electrical hazards (EN 50110-1 standard, DIN VDE 0682-401, NF C 18-510, etc.). To secure the installation and ensure that it is non-current-carrying, there is a procedure called Separation which imposes the use of a Voltage Absence Tester.

The C.A 773's comprehensive Autotest checks the electrical circuits, the power supply, the displays and the condition of the measurement leads. Audible and visual continuity testing is provided in compliance with Appendix B of the standard. The tester can also detect stray voltages and offers unipolar phase identification


All indoor and outdoor low-voltage applications

CAT IV 1,000 V Voltage Absence Testers (VATs) Use in extreme conditions: type-N extended climatic class RCD trip testing Digital display Complete integrated Autotest Extended continuity test (R< 0.5 Ω to 2.999 kΩ) Two-pole phase-sequence testing with "2-wire method" up to 400 Hz, suitable for isolating transformers and electrical generator sets

CA 773 & CA 771: beyond the standard recommendations

  • A comprehensive integrated autotest with indication of the type of fault. The CA773 also displays a text message for complete information.
  • The CA 773 & CA 771 VATs benefit from IP65 protection for indoor and outdoor use, which is significantly higher than the IP54 rating required by the standard.
  • Extended class: for extreme environments, the CA 773 can be used for measurements from -15 °C to +45 °C (Class N).
  • Audible and visual continuity indication up to 100 Ω, in compliance with the recommendation in Appendix B of the standard.
  • The test probes are removable to meet specific requirements or to comply with the legislation in certain countries. Various models are available, including IP2X versions. Various models are available, including IP2X versions (required by the EN 61243 standard, for example).
  • The CA 773 has significant measurement ranges and capabilities over it's counterpart CA 771, for a full breakdown please see the table below.

The Chauvin Arnoux CA 771 is available here.


 

Key Features:

  • CAT IV 1,000 V
  • IP65
  • Full autotest
  • Voltage detection, LED display + backlit digital display: 12 VAC ≤ U ≤ 1,000 VAC • 12 VDC ≤ U ≤ 1,400 VDC
  • Frequency: DC, 162/3 to 800 Hz
  • Stray voltage detection
  • Unipolar phase detection (a single contact)
  • Two-pole phase-sequence testing with 2-wire method = a third hand is not required
  • Continuity test with audible and visual indication (R < 100 Ω)
  • Extended continuity test with visual indication for R < 0.5 Ω to 2.999 kΩ
  • RCD trip test
  • Complies with EN 61243-3 & IEC 61010 1000 V CAT IV
  • Climatic conditions: -15 °C to +45 °C (Class N)
  • Battery life > 2,500 x 10 s measurements
  • Removable lead and test probe
  • Delivered complete and ready to use

 

Single-pole phase detection

You can detect the phase simply by establishing contact with one of the test probes

2-wire phase rotation with microprocessor

Simple and quick, the 2-wire phase rotation function with microprocessor is useful in all circumstances, including on installations powered by an electrical generator set or behind an isolating transformer.

Continuity and resistance testing

By pressing the continuity button, you can check that the conductors are correctly connected. Continuity (R < 100 Ω) is indicated by a loud, continuous audio signal. In addition, the CA 773 offers an extended continuity test and can be used to display the higher values from 0.5 Ω to 2.999 kΩ. The CA 773 displays the resistance value directly.

Residual Current Device (RCD) trip test up to 30 mA

By simultaneously pressing the double command, you can cause a fault current sufficient to trip the RCD to flow through a low-impedance load.

Applications:

Voltage up to 1,000 Vac / 1,400 Vdc at up to 800 Hz

The specifications of the CA 771 and CA 773 mean they can be used for work on all LV electrical networks, whether they are electricity distribution networks or the more specific networks encountered in naval or aviation applications.

The CA773 Comes Supplied With:

  • 1 operating manual in 5 languages
  • 2 x 1.5 V LR06/AA batteries
  • 1 set of IP2X removable test probes
  • 1 Velcro strap.

Climatic Conditions

The type-S extended climatic class allows use in extreme temperature conditions. This means it offers an operating range from -15 °C to +45 °C (Class N) for applications such as:

  • Installations at altitude (mountains, etc.), underground installations, etc.
  • Refrigeration installations, greenhouses, etc.,
  • Service vehicles (emergency, army, etc.)
  • The IP65 protection rating also ensures maximum protection against solid pollutants (dust) and liquid pollutants (projections), allowing both indoor and outdoor use.

Ergonomics specially designed for use in the field

  • Digital display (CA 773) with text
  • 2 moulded test probes to ensure excellent handling while protecting against falls and shocks
  • Built-in torch to light the point of measurement
  • Removable test probes and 2 positions provided on the VAT for 16 or 19 mm spacing

Chauvin Arnoux CA 771 & CA 773 Technical Specification Key Differences
Technical Specifications CA771 CA773
Display LEDs LEDs + backlit digital display
Voltage

12 Vac ≤ U ≤ 1,000 Vac 12 Vdc ≤ U ≤ 1,400 Vdc

 

1.0 V to 299.0 Vac/dc

300 V to 1,000 Vac / 1,400 Vdc

Extended continuity test (resistance) 2 kΩ, 60 kΩ, 300 kΩ 0.5 Ω to 2,999 kΩ
Climatic conditions -30 °C to +60 °C (Class S) -15 °C to +45 °C (Class N)
Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements


Spares & Accessories (Not Included):

The CA 753 measurement adapter can be used for measurements in total safety on European 2P+E and Schuko sockets.
Its design guarantees mechanical and electrical contact with all test probes (Ø 2 mm, Ø 4 mm, IP2x, etc.). The presence of a voltage (> 200 V) and the phase position are also indicated.

Removable accessories according to the requirements

Isolated test probes 2 or 4 mm in diameter, IP2X tip protection and test probes.


  

  • CAT IV test probes for VATs P01102123Z
  • Test probes Ø 2 mm for VATs P01102124Z
  • Test probes Ø 4 mm for VATs P01102125Z
  • Probe-tip protection for VATs P01102126Z
  • CAT IV IP2X probes for VATs P01102127Z
  • IP2X Ø 4 mm probes for VATs P01102128Z
  • MultiFix bag, 120 x 320 x 60 mm P01298076
  • CA 753 measurement adapter for European 2P+E sockets P01191748Z 

isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.

ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.

Features & Specification

More Information
Key Features 1000V CAT IV, Audible and visual continuity, Digital display, IEC 61243-3, Rated IP65, RCD trip testing, Single Pole Phase Testing
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Chauvin Arnoux
Short Description

Chauvin Arnoux CA 771 & CA 773 Technical Specification
Technical Specifications CA771 CA773
Display LEDs LEDs + backlit digital display
Voltage absence testing (VAT)
Voltage

12 Vac ≤ U ≤ 1,000 Vac 12 Vdc ≤ U ≤ 1,400 Vdc

1.0 V to 299.0 Vac/dc

300 V to 1,000 Vac / 1,400 Vdc

Frequency DC, 162/3 to 800 Hz
Impedance > 500 kΩ
Max. peak current 3.5 mA RMS
Polarity indication Yes
Redundant hazardous-voltage indication The ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage) with the rate at which it flashes proportional to the voltage level
Stray voltage detection Yes (by low-impedance load switching)
RCD tripping Yes (by low-impedance load switching) (approx. 30 mA at 230 V)
Phase/Neutral identification

Above 50 V (45 - 65 Hz)

Above 150 V (162/3 - 45 Hz)

Continuity & Resistance
Buzzer trigger threshold 100 Ω typical (150 Ω max.)
Extended continuity test (resistance) 2 kΩ, 60 kΩ, 300 kΩ 0.5 Ω to 2,999 kΩ
Test current / Open-circuit voltage ≤ 1 mA / ≤ 3.3 V
Phase rotation 2-wire method with microprocessor
Ph/Ph voltage 50 V ≤ U ≤ 1,000 Vac (45 - 400 Hz)
Buzzer

Intermittent beep for Voltage Detection

Continuous beep for continuity

Standards and electrical safety IEC 61243-3:2009, EN 61243-3:2010, IEC 61010 1,000 V CAT IV
Enclosure protection IP65
Climatic conditions -30 °C to +60 °C (Class S) -15 °C to +45 °C (Class N)
Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements
Dimensions / weight 228 x 60 x 39 mm (without test probes) / 350 g approx.

Chauvin Arnoux CA 771 & CA 773 Technical Specification Key Differences
Technical Specifications CA771 CA773
Display LEDs LEDs + backlit digital display
Voltage

12 Vac ≤ U ≤ 1,000 Vac 12 Vdc ≤ U ≤ 1,400 Vdc

1.0 V to 299.0 Vac/dc

300 V to 1,000 Vac / 1,400 Vdc

Extended continuity test (resistance) 2 kΩ, 60 kΩ, 300 kΩ 0.5 Ω to 2,999 kΩ
Climatic conditions -30 °C to +60 °C (Class S) -15 °C to +45 °C (Class N)
Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA