Chauvin Arnoux CA 6528 1kV Megohmmeter & Digital Multimeter P01140838

£369.24

Chauvin Arnoux CA 6528 Technical Specification

Voltage
Measurement range/ resolution 1‐700 V / 1 V
Accuracy / input impedance ±1.2% R ± 1ct for AC+DC; ±1 R ± 1ct for DC / 25 MΩ
Operating frequency DC; 30‐440 Hz
Insulation
Test voltage 250-500-1,000 V
Range at maximum test voltage 11 GΩ
Compliance with the IEC 61557‐2 standard 2 GΩ
Measurement range
250V 50 kΩ ‐ 4.2 GΩ
500V 100 kΩ ‐ 4.2 GΩ
1000V 200 kΩ ‐ 11 GΩ
Measurement range / resolution 50 kΩ ‐ 3.999 / 1 kΩ; (0.2)* 3.6‐39.99 MΩ / 10 kΩ; 36‐399.9 MΩ / 100 kΩ; 360‐4,200 MΩ / 1 MΩ; (1 kV) 3.6 ‐ 11.00 GΩ / 10 MΩ
Accuracy 0.05‐399.9 MΩ : ±1.5 R ± 10cts; 360 ‐4,200 MΩ: ±4 R ± 10cts ; ±4 R ± 5cts (at 1,000 V); 3.6‐11 GΩ: ±10 R ± 10cts
Test voltage (I <1 mA) 0%+20%
Timer (min:s) 10s to 39min 59s
Alarms 1 threshold / test voltage
Continuity
Measurement range 0.02 Ω ‐ 40 Ω (200 mA)
Accuracy / open-circuit voltage ±1.2% R ±3cts / 6 VDC < U < 9 VDC
Measurement current ≥ 200 mA (up to 2 Ω)
Continuity threshold (fast beep) 2 Ω / 1 Ω
Cable compensation up to 5 Ω
Resistance
Measurement range / resolution 1 ‐399.9 Ω / 0.1 Ω; 360‐3,999 Ω / 1 Ω; 3.60‐39.99 kΩ / 10 Ω; 36.0‐420.0 kΩ / 100 Ω
Accuracy ±1.2% R ±3cts
General Specifications
Display 2 x 4,000 cts
Power supply / Automatic power-of 6 x LR 6 or AA batteries / 10 min deactivatable
Battery life 1,000 measurements: at 1 MΩ @ 1 kV (5 s ON / 25 s OFF); >3,000 continuity measurements (5 s ON / 25 s OFF) at 1 Ω
Dimensions / weight / IP rating 218 x 95 x 63 mm / 760 g / IP 40
EMC / electrical safety IEC 61326‐1 / IEC 61010‐1, IEC 61010‐2‐030 and IEC 61010‐2‐034 / 600V CAT IV
Compliance with standards IEC 61557 parties 1, 2, 4 and 10

*at 1,000V

Description

Chauvin Arnoux CA6528 1kV Megohmmeter & Digital Multimeter

The CA6528 insulation and continuity tester is designed for use in the field: lightweight, compact, rugged, and easy to handle, even when wearing gloves. Its ergonomics are intended to simplify its use.

*Important Calibration Information:

This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a fully traceable calibration certificate produced in our laboratory and applied with your details as required.


CA6528 Comes Supplied With:

  • Hands-free carry bag
  • 2 safety leads, 1 red and 1 black
  • Set of Crocodile Clips
  • Protective Sheath
  • 6 x LR6 or AA batteries
  • 1 safety datasheet
  • 1 quick start guide
  • 1 verification certificate

The CA 6528 insulation tester is ideal for maintenance and repair operations on electrical equipment such as motors, cables, etc. Thanks to its "hands-free" bag, the CA 6528 insulation tester can be used without any constraints in the field. The shockproof sheath with stand (props) ensure stability on horizontal surfaces. 

The large LCD screen can show the insulation value and the real test voltage simultaneously thanks to its double display. The backlighting makes it easy to read in all circumstances. 

The CA 6528 megohmmeter measures resistance, insulation and continuity according to the applicable international standards: IEC 60364, NF C 15-100, VDE 100, etc. The continuity measurement integrates compensation of the cables. Insulation measurement is possible in manual mode, locked mode or programmed-duration mode with the timer. When measuring the voltage, an indicator shows the battery status.

The CA 6528 indicates the test results instantaneously: the screen turns red if the threshold is overrun.

The presence of a hazardous voltage (>30 V) is detected automatically by the CA 6528, which then prohibits insulation testing. 

Key Features:

  • Double digital display to view the insulation value and real test voltage simultaneously in an easy-to-read format
  • 2-colour backlighting
  • Shockproof sheath for excellent handling
  • Stand for stability when used on a horizontal surface
  • Bag with a built-in neck strap for hands-free use and to stow your measurement accessories
  • Automatic power-off function to optimize the battery life
  • Programmable alarm thresholds to view the test result instantaneously

Ergonomics:

The CA 6528 insulation and continuity tester is designed for use in the field: lightweight, compact, rugged, and easy to handle, even when wearing gloves. Its ergonomics is intended to simplify its use:

  • Double digital display to view the insulation value and real test voltage simultaneously in an easy-to-read format
  • 2-colour backlighting
  • Shockproof sheath for excellent handling 
  • Stand for stability when used on a horizontal surface
  • Bag with built-in neck strap for hands-free use and to stow your measurement accessories
  • Automatic power-off function to optimize the battery life
  • Programmable alarm thresholds to view the test result instantaneously

Applications

The CA 6528 is mainly used to check the safety of electrical installations. It measures resistance, insulation and continuity in compliance with the applicable standards: IEC 60364, NF C 15-100, VDE 100, etc. It is also ideal for maintenance and repair of electrical equipment such as motors, cables, etc.

Preventative Maintenance

In addition to the measurements carried out on new and reconditioned equipment during commissioning, regular insulation testing on installations and equipment helps to avoid such incidents through preventive maintenance. These tests detect ageing and premature deterioration of the insulating properties before they reach a level likely to cause problems. The severity of such incidents may affect the safety of people and property, as well as generating production downtime costs in industry.

Measurements

The CA 6528 insulation tester can measure insulation at 250 V / 500 V / 1,000 V, making it ideal for a large number of applications. It offers high-performance insulation resistance measurements up to 11 GΩ, while also measuring resistance up to 420 kΩ and voltage up to 700 VAC/DC. In compliance with the applicable standards, continuity measurement is performed with a test current ≥ 200 mA. This measurement directly integrates automatic compensation of cable resistance for greater accuracy.

Safety

The CA 6528 is a safe instrument. The presence of a hazardous voltage is detected automatically. Insulation measurement in the presence of a voltage greater than 30 V is automatically inhibited, making insulation testing impossible.

 

Insulation measurement in manual or locked mode or with a duration programmed using the timer Insulation measurement with simultaneous display of the insulation and the real test voltage

 

 


Spares and Accessories (Not Supplied):

  • Set of red and black safety leads 1.5 m long: P01295289Z
  • Red + black crocodile clips: P01295457Z
  • Red + black test probe: P01295454Z
  • Continuity rod: P01102084A




isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.

ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.

Features & Specification

More Information
Key Features 600V CAT IV IP40, Automatic voltage detection, Compliant with IEC 61557-1-2-4-10, Continuity: 0.02 Ω to 40 Ω, Insulation: up to 11 GΩ, Resistance: 1 Ω to 420 kΩ, Voltage: 0 to 700 VAC/DC
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Chauvin Arnoux
Short Description

Chauvin Arnoux CA 6528 Technical Specification

Voltage
Measurement range/ resolution 1‐700 V / 1 V
Accuracy / input impedance ±1.2% R ± 1ct for AC+DC; ±1 R ± 1ct for DC / 25 MΩ
Operating frequency DC; 30‐440 Hz
Insulation
Test voltage 250-500-1,000 V
Range at maximum test voltage 11 GΩ
Compliance with the IEC 61557‐2 standard 2 GΩ
Measurement range
250V 50 kΩ ‐ 4.2 GΩ
500V 100 kΩ ‐ 4.2 GΩ
1000V 200 kΩ ‐ 11 GΩ
Measurement range / resolution 50 kΩ ‐ 3.999 / 1 kΩ; (0.2)* 3.6‐39.99 MΩ / 10 kΩ; 36‐399.9 MΩ / 100 kΩ; 360‐4,200 MΩ / 1 MΩ; (1 kV) 3.6 ‐ 11.00 GΩ / 10 MΩ
Accuracy 0.05‐399.9 MΩ : ±1.5 R ± 10cts; 360 ‐4,200 MΩ: ±4 R ± 10cts ; ±4 R ± 5cts (at 1,000 V); 3.6‐11 GΩ: ±10 R ± 10cts
Test voltage (I <1 mA) 0%+20%
Timer (min:s) 10s to 39min 59s
Alarms 1 threshold / test voltage
Continuity
Measurement range 0.02 Ω ‐ 40 Ω (200 mA)
Accuracy / open-circuit voltage ±1.2% R ±3cts / 6 VDC < U < 9 VDC
Measurement current ≥ 200 mA (up to 2 Ω)
Continuity threshold (fast beep) 2 Ω / 1 Ω
Cable compensation up to 5 Ω
Resistance
Measurement range / resolution 1 ‐399.9 Ω / 0.1 Ω; 360‐3,999 Ω / 1 Ω; 3.60‐39.99 kΩ / 10 Ω; 36.0‐420.0 kΩ / 100 Ω
Accuracy ±1.2% R ±3cts
General Specifications
Display 2 x 4,000 cts
Power supply / Automatic power-of 6 x LR 6 or AA batteries / 10 min deactivatable
Battery life 1,000 measurements: at 1 MΩ @ 1 kV (5 s ON / 25 s OFF); >3,000 continuity measurements (5 s ON / 25 s OFF) at 1 Ω
Dimensions / weight / IP rating 218 x 95 x 63 mm / 760 g / IP 40
EMC / electrical safety IEC 61326‐1 / IEC 61010‐1, IEC 61010‐2‐030 and IEC 61010‐2‐034 / 600V CAT IV
Compliance with standards IEC 61557 parties 1, 2, 4 and 10

*at 1,000V

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA