Chauvin Arnoux AC Current Clamp Model C177A P01120336

£322.80

Chauvin Arnoux AC Current Clamp Model C177A

Meter Compatibility C.A 6116N, C.A 6117
Maximum Clamping Diameter 2.05" (52mm)
Current Range 200A
Measurement Range 5mA to 200A
Transformation Ratio 10,000:1
Output 6.5ft (2m) lead with proprietary CA connector
Operating Temperature 32° to +113°F  (0° to +45°C); 90% RH
Storage Temperature -40° to +158°F  (-40° to +70°C)
Operating Relative Humidity 90% RH
Dimensions  (HxWx D) 8.50 x 4.37 x 1.77” (216 x 111 x 45mm)
Weight 1.21 lb (550g)
Pollution Degree 2
Ingress Protection IP 40, IP 30 with jaws open
Safety Compliance IEC 61010-2-032, EN 61010-1, EN61010-031 300V CAT IV,
600V CAT III
NEW

Description

Chauvin Arnoux AC Current Clamp Model C177A

The AC Current Probe Model C177A features a measurement range of 5mA to 200A, with a transformation ratio of 10,000:1. Its maximum clamping diameter is 2.05" (52mm). The probe includes a 6.5' (2m) lead with a proprietary CA connector.
 
The Model C177A is designed for use with Multi-Function Installation Testers Models C.A 6116/6116N, and C.A 6117.
 
You can find more information on the Chauvin Arnoux CA6117 combined multifunction tester and power analyser here.
 

The high-performance CA 6117 offers excellent measurement stability, even in disturbed industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, earth and selective earth, loop impedances, type A and AC RCDs. The CA 6117 can also be used to measure voltage, frequency, current via a clamp, active power, harmonics and phase rotation.

The CA 6117 is also fitted with type-B RCD testing, built-in fuse table and voltage-drop feature.
Designed and manufactured in France, the CA 6117 was developed in compliance with eco-design procedures.

Power Analyser Mode:

In the modern workplace electricians must deal with an array of complex array of work and equipment, by having high spec equipment , such as the CA6117 multi-function tester,  they can be prepared for every eventuality encountered. Many MFTs prove sufficient for basic safety testing, but when it comes to fault finding, commissioning and diagnostics,  advanced MFTs like the CA6117 come into their own by providing everything the modern electrician needs in one product.

 The CA6117 can display voltage, and, by using the optional current clamp, current waveforms while also displaying both peak (max) and RMS values. This proves useful in identifying any waveform distortion, possibly from harmonics or other sources. Power can also be displayed with direction indication for imported or exported power, ideal where microgeneration such as PV systems are present. Power Factor can be measured and seen on the graphical display. These features are essential for those working in modern electrical systems with capacitive, inductive and non-linear loads present. The ability to see these values in real-time assists in quickly diagnosing issues within the installation or supply. They are also essential when configuring or testing equipment such as power factor correction capacitor banks.

Using the voltage input and optional current clamp, the CA6117 has the ability to accurately measure and display Voltage and Current Harmonics up to the 50th harmonic order, performance typically only seen on dedicated power quality analysers or loggers. All modern electrical installations contain non-linear loads which generate harmonics.
These harmonics can cause many issues within installations, such as the overheating and premature failure of equipment. The only way to identify the underlying cause of these issues is by using a meter such as the CA6117 or an expensive power quality analyser or logger. The CA6117 has the ability to display Total Harmonic Distortion (THD), a simple measure of the amount of harmonics present. It can also show each of the 50 individual harmonics in graphical or numerical form. This powerful feature allows the electrician to identify specific harmonic issues and also check the effectiveness of harmonic mitigation measures, such as active harmonic filters.

 

A stand-out feature of the CA 6117 is its ultra-accurate Earth Fault Loop Impedance (Zs) measurement capability. Unlike most MFTs on the market, the CA 6117 is able to measure Zs to three decimal places and test lead resistance can also be nulled in Zs mode. In heavy duty installations or where working on installations close to the supply transformer, Zs values can be very low. To measure such low values, which are beyony the meaningful range of most MFTs, electricians may have to buy a expensive specialist stand-alone loop tester, but not with the CA 6117 which can measure these values using its normal high current Zs range.

 

isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond. 

isswww and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over. 

Features & Specification

More Information
Key Features Exclusively for the CA611x Testers, Measurement Range 5mA to 200A AC, Transformation ratio of 10000:1, Clamping diameter is 2.05" (52mm), Includes a 6.5' (2m) lead
Manufacturer Chauvin Arnoux
Short Description

Chauvin Arnoux AC Current Clamp Model C177A

Meter Compatibility C.A 6116N, C.A 6117
Maximum Clamping Diameter 2.05" (52mm)
Current Range 200A
Measurement Range 5mA to 200A
Transformation Ratio 10,000:1
Output 6.5ft (2m) lead with proprietary CA connector
Operating Temperature 32° to +113°F  (0° to +45°C); 90% RH
Storage Temperature -40° to +158°F  (-40° to +70°C)
Operating Relative Humidity 90% RH
Dimensions  (HxWx D) 8.50 x 4.37 x 1.77” (216 x 111 x 45mm)
Weight 1.21 lb (550g)
Pollution Degree 2
Ingress Protection IP 40, IP 30 with jaws open
Safety Compliance IEC 61010-2-032, EN 61010-1, EN61010-031 300V CAT IV,
600V CAT III
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA