Chauvin Arnoux CA5292 Recorder Multimeter P01196802

£611.88
Chauvin Arnoux CA 5292 & CA 5293 Recorder Multimeter Technical Specification
CA 5292 CA 5293
DC, AC and AC+DC voltages TRMS
Range 100 mV */ 1000 mV / 10 V / 100 V / 1000 V
Resolution 1 μV / 10 μV / 0.1 mV / 1 mV / 10 mV
AC and AC+DC bandwidth 100 kHz 200 kHz
DC accuracy 0.03% 0.02%
AC and AC+DC (VLowZ) accuracy 0.3% 0.3%
DC, AC and AC + DC TRMS current
Range 1000 μA / 10 mA / 100 mA / 1000 mA / 10 A / 20 A (30s max on 100 A range)
Resolution 10 nA / 0.1 μA / 1 μA / 10 μA / 100 μA / 1000 μA
DC / AC and AC+DC accuracy 0.08% / 0.3%
AC and AC+DC bandwidth 50 kHz
Frequency
Frequency Range 10 Hz / 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz / 5 MHz
Resolution 0.0001 Hz / 0.001 Hz / 0.01 Hz / 0.1 Hz / 1 Hz / 10 Hz / 100 Hz
Resistance and continuity
Ranges 100 Ω */ 1 kΩ / 100 kΩ / 1000 KΩ / 10 MΩ / 100 MΩ
Resolution 0.001 Ω / 10 mΩ / 100 kΩ / 10Ω / 10Ω / 1 kΩ
Basic Accuracy 0.07%
Protection 1000 V electronic protection
Audible Continuity Detection 1000 Ω / SIGNAL <20 Ω < 3.5 V
Diode Test
Threshold voltage measurement Diode 0 -2.6 V <1 mA + Zener diode or LED 0-2.6 V <11 mA
Capacitance
Ranges 1 nF / 10 nF / 100 nF / 1000 nF / 10 μF / 100 μF / 1 mF / 10 mF
Resolution (Manual access) 1 pF / 10 pF / 0.1 nF / 1 nF / 0.01 μF / 0.1 μF / 1 μF / 10 μF
Temperature with Pt100/1000 and K/J thermocouples
Operating Range ples Operating range -200 °C to +800° C with Pt and -40 to +1200 °C with K thermocouple
Accuracy .01%
Other Measurement functions
SURV MAX/MIN/AVG Time/date-stamped on all the main positions
REL Reference-delta relative value on 3 displays + main measurement
PWM filter 4th order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors
SPEC Display of the measurement tolerance + Smin + Smax
GRAPH Trends of main measurements with max., variable time and display of waveform (50/60 and 600 Hz)
Secondary measurements 3 measurements + main measurement
Measurement storage 10,000 30,000
General Specifications
Type of display Colour graphical (70x52) with backlighting and black background on 4 x 100,000-count displays
PC interfaces Optical USB connector or Bluetooth (option)– SX-DMM software and ANDROID application
Power supply USB-type charger or 4 AA batteries or NiMH rechargeable batteries
Safety / EMC Safety as per IEC 61010-1, IEC 61010-2-033 1000 V-CAT III /600 V CAT IV EMC as per EN 61326-1
Environment Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C
Mechanical specifications Dimensions (L x W x H): 196x90x47.1 mm – Weight: 570 g
Warranty 3 years

Description

Chauvin Arnoux CA5292 Recorder Multimeter P01196802

Recorder Multimeters with Graphical Colour Screen

The ASYC IV portable multimeters with a graphical colour display can be used for direct measurement of the main electrical quantities and instantaneous viewing of the trends and waveform. These multimeters are compact, rugged, watertight and specially designed for easy handling.
Multiple quantities measured around the main function, as well as functions for specification, relative measurement, mathematical functions and direct current measurement using a clamp make these multimeters genuine measurement experts.


Simultaneously portable and benchtop multimeters, the ASYC IV models are simple and intuitive. Accessible directly, the various measurements are represented explicitly in the form of pictograms on the electronic switch. The display allows users to view the measurement results either as numeric values or as graphs showing the trend over time. Recorded measurements can be displayed as traces, with the possibility of positioning cursors and zooming on a part of the recorded curve. An integrated help function available in French and English provides information on the measurements in progress. USB or BT communication is provided to transfer the data onto a PC for saving and programming with the LV/LW drivers. Once the instrument is connected to the PC, the firmware can be updated by accessing the “Loader” program on the web.

*Important Calibration Information:

This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a fully traceable calibration certificate produced in our laboratory and applied with your details as required.

CA5292 Recorder Multimeter Comes Supplied With:

  • 4 x 1.5 V NiMH rechargeable batteries
  • 1.5 m straight/straight red cable
  • 1.5 m straight/straight black cable
  • Red CAT IV 1 kV test probe
  • Black CAT IV 1 kV test probe
  • USB optical communication cable + SX-DMM software
  • USB charger + USB connection cable
  • User’s Manual on CD and multilingual start-up guide on paper

Memory Capacity and connectivity, choosing the right model

The CA 5292 (this model) has an internal storage of up to 10,000 measurements.
The CA 5293 (available here) has an internal storage of up to 30,000 measurements.
Both the CA 5292 and 5293 come with an optical USB interface as standard for connecting to your PC facilitating data transfer.
if you prefer a wireless Bluetooth connection please choose the CA 529xBT option in the drop-down menu above, there is a small additional charge for this feature.
AC and AC+DC Bandwidth CA 9252: 100 kHz  CA 9253: 200 kHz
DC Accuracy CA 9252: 0.03%  CA 9253: 0.02%

High-performance graphical multimeters...
Easy-to-read 320 x 240-pixel colour matrice screen with black background
• Multi-parameter graphical display of the trends on a summary screen
• Display of the waveform at 50 / 60 and 600 Hz
• Trace, cursors and zoom on the recordings
• Internal recording of 10 sequences

Dynamic recorders...
• Up to 10,000 measurements stored in memory
• Simplified parameterization of the number of measurements, the interval, the duration and the storage capacity
• Internal storage of 10 measurement sequences
• Interactive zoom function on the recordings
• A simple monitoring mode displaying the time/date-stamped MIN/MAX/PEAK+/PEAK- and AVG values

... And much more!
• Contextual reminder of connections
• Traditional USB communication with Bluetooth available as an option
• IP67 protection, withstands water projections and dust, ideal for outdoor conditions
• Commercially-available Ni-MH AA rechargeable battery, the best quality/price trade-off
• Battery life of up to 100 hrs on battery with management of battery level
• No time wasted: the instrument operates while charging

ASYC IV multimeters are ideal for many applications in the industrial sector, telecommunications and Defence. Their multiple functions make them easy to use for electrical, electronics and machine maintenance. In the electronics sector, the ASYC IV models can be used to test wiring, IT or medical equipment and SMDs. With their IP67 protection, they are designed to be dustproof and watertight for difficult environments. In industry, they are ideal for applications involving automation and processes in a wide variety of sectors: agri-food, plastics, concrete, metal, paper, wood, oil, nuclear. ASYC IV multimeters can be used for the maintenance of many industrial machines: numerical control systems, motors, generators, etc. These versatile instruments are also suitable for the needs of expert electrical installers and professionals in the transport and energy sectors. The high-performance, affordable and ergonomic ASYC IV models also have their place in education and research.

isswww and Chauvin Arnoux

The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.

 

Features & Specification

More Information
Key Features 0.02% Accuracy, 1000V CAT III, Android Connectivity, Intuative Multi-lingual Interface, Multiple Analytical Tools, Multiple Parameter Full Colour Screen, Top of the Range Specification, Up to 30,000 Measurement Storage
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Chauvin Arnoux
Short Description
Chauvin Arnoux CA 5292 & CA 5293 Recorder Multimeter Technical Specification
CA 5292 CA 5293
DC, AC and AC+DC voltages TRMS
Range 100 mV */ 1000 mV / 10 V / 100 V / 1000 V
Resolution 1 μV / 10 μV / 0.1 mV / 1 mV / 10 mV
AC and AC+DC bandwidth 100 kHz 200 kHz
DC accuracy 0.03% 0.02%
AC and AC+DC (VLowZ) accuracy 0.3% 0.3%
DC, AC and AC + DC TRMS current
Range 1000 μA / 10 mA / 100 mA / 1000 mA / 10 A / 20 A (30s max on 100 A range)
Resolution 10 nA / 0.1 μA / 1 μA / 10 μA / 100 μA / 1000 μA
DC / AC and AC+DC accuracy 0.08% / 0.3%
AC and AC+DC bandwidth 50 kHz
Frequency
Frequency Range 10 Hz / 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz / 5 MHz
Resolution 0.0001 Hz / 0.001 Hz / 0.01 Hz / 0.1 Hz / 1 Hz / 10 Hz / 100 Hz
Resistance and continuity
Ranges 100 Ω */ 1 kΩ / 100 kΩ / 1000 KΩ / 10 MΩ / 100 MΩ
Resolution 0.001 Ω / 10 mΩ / 100 kΩ / 10Ω / 10Ω / 1 kΩ
Basic Accuracy 0.07%
Protection 1000 V electronic protection
Audible Continuity Detection 1000 Ω / SIGNAL <20 Ω < 3.5 V
Diode Test
Threshold voltage measurement Diode 0 -2.6 V <1 mA + Zener diode or LED 0-2.6 V <11 mA
Capacitance
Ranges 1 nF / 10 nF / 100 nF / 1000 nF / 10 μF / 100 μF / 1 mF / 10 mF
Resolution (Manual access) 1 pF / 10 pF / 0.1 nF / 1 nF / 0.01 μF / 0.1 μF / 1 μF / 10 μF
Temperature with Pt100/1000 and K/J thermocouples
Operating Range ples Operating range -200 °C to +800° C with Pt and -40 to +1200 °C with K thermocouple
Accuracy .01%
Other Measurement functions
SURV MAX/MIN/AVG Time/date-stamped on all the main positions
REL Reference-delta relative value on 3 displays + main measurement
PWM filter 4th order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors
SPEC Display of the measurement tolerance + Smin + Smax
GRAPH Trends of main measurements with max., variable time and display of waveform (50/60 and 600 Hz)
Secondary measurements 3 measurements + main measurement
Measurement storage 10,000 30,000
General Specifications
Type of display Colour graphical (70x52) with backlighting and black background on 4 x 100,000-count displays
PC interfaces Optical USB connector or Bluetooth (option)– SX-DMM software and ANDROID application
Power supply USB-type charger or 4 AA batteries or NiMH rechargeable batteries
Safety / EMC Safety as per IEC 61010-1, IEC 61010-2-033 1000 V-CAT III /600 V CAT IV EMC as per EN 61326-1
Environment Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C
Mechanical specifications Dimensions (L x W x H): 196x90x47.1 mm – Weight: 570 g
Warranty 3 years

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA