Fluke i5S AC Current Clamp

£698.40
Specifications
Nominal current range 5 A
Continuous current range 10 mA to 6 A
Maximum Non-Destructive Current 70 A
Lowest measurable current 10 mA
Basic Accuracy   48 Hz to 65 Hz
10 mA to 1 A 1% + 5 mA
1 A to 5 A 1%
Useable frequency 40 Hz to 5 kHz
Output level(s) 400 mV/A
Input Load Impedance > 1 MΩ in parallel with up to 47 pF
Crest Factor ≤ 3, add 0.7% to accuracy
Safety Specifications
Safety CAT III 600 V per IEC/EN61010-1, Pollution Degree 2
Maximum voltage 600 V AC
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 15 mm
Output cable length 2.5 m
BNC Adapter Yes
BNC to banana adapter included No

Description

Fluke i5S AC Current Clamp


Expand the use of your Fluke 430 series power quality tool or ScopeMeter test tool with this 5 A AC current clamp, specially configured to provide good accuracy at low levels e.g. while taking measurements on secondary current transformers.


Key Features:

  • Low level current clamp measures up to 5 A AC
  • Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 in)
  • Take accurate readings without breaking the circuit
  • CAT III 600 V (For insulated conductors only)
 

The Fluke i5S AC Current Clamp Models:

  • Fluke i5S AC Current Clamp - Single Clamp
  • Fluke i5S AC Current Clamp - Pack of 3 Clamps
 

Fluke excel in manufacturing Power Quality Analysers and have always produced a massive range of accesories to support them. Fluke offer a massive range of current clamps with a choice of phases and current. They also host a large range of flexi current clamps for those tighter situations. They manufacturer new leads, probes clipms, transformers, shunts and probes. With so many accesories for so many power quality analysers it can be easy to get confused over which is the best one for you and your analyser. Get in touch and speak to our technical sales staff to help point you in the right direction to which accesory is best for you.

Features & Specification

More Information
Key Features AC Current Clamp, BNC Adaptor
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Specifications
Nominal current range 5 A
Continuous current range 10 mA to 6 A
Maximum Non-Destructive Current 70 A
Lowest measurable current 10 mA
Basic Accuracy   48 Hz to 65 Hz
10 mA to 1 A 1% + 5 mA
1 A to 5 A 1%
Useable frequency 40 Hz to 5 kHz
Output level(s) 400 mV/A
Input Load Impedance > 1 MΩ in parallel with up to 47 pF
Crest Factor ≤ 3, add 0.7% to accuracy
Safety Specifications
Safety CAT III 600 V per IEC/EN61010-1, Pollution Degree 2
Maximum voltage 600 V AC
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 15 mm
Output cable length 2.5 m
BNC Adapter Yes
BNC to banana adapter included No

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA