Fluke 1760 Three Phase Power Quality Recorder

£14,694.00
Overview of Measurement Functions
Statistical Evaluation
   Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI
Event List
   Dips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list.
   The Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis.
   RMS values, transients and fast transients can be stored if a trigger fires.
Continuous Recording
   Fluke 1760 records rms values together with corresponding minimum and maximum values for:
   • Voltage
   • Current
   • Power P, Q, S
   • Power Factor
   • kWh
   • Flicker
   • Unbalance
   • Frequency
   • Harmonics/Interharmonics
   continuously with the following time aggregations:
   Day
   10 min
   Free Interval, e.g.: 15 min, 2h
Triggered Recordings
rms:  Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
   Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency.
   Basic aggregation for harmonics and interharmonics is 200ms
Oscilloscope:  Sample rate is 10.24 kHz for all 8 channels
Fast Transients:  Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients
Mains Signalling
   Phases and N-conductor, Voltage and current
Online Mode
   Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.

 

General Data
Intrinsic uncertainty
   refers to reference conditions and is guaranteed for two years
Quality system
   developed, manufactured as per ISO 9001: 2000
Environment conditions
Operating temp. range:  0 °C to +50 °C; 32 °F to +122 °F
Working temp. range:  -20 °C to +50 °C; -4 °F to +122 °F
Storage temp. range:  20 °C to +60 °C; -4 °F to 140 °F
Reference temperature:  23 °C ± 2 K; 74 °F ± 2 K
Climatic class:  B2 (IEC 654-1), -20 °C to +50 °C; -4 °F to +122 °F
Max. operating altitude:  2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II 
* depending on sensor
Reference conditions
Environment temp.:  23 °C ± 2 K ; 74°F ± 2 K
Power supply:  230 V ± 10 %
Power frequency:  50 Hz / 60 Hz
Signal:  declared input voltage Udin
Averaging:  10 minute intervals
Housing
   insulated, robust plastics housing
EMC
Emission:  Class-A as per IEC/EN 61326-1
Immunity:  IEC/EN 61326-1
Power supply
Range:  AC: 83 V to 264 V, 45 to 65 Hz
   DC: 100 V to 375 V
Safety:  IEC/EN 61010-1 2nd edition
   300 V CAT III
Power consumption:  max. 54VA
Battery pack:  NIMH, 7.2 V, 2.7 Ah
   In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.
Display
   Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.
Power LED:  • Permanent light: normal power supply from mains.
   • OFF: supply via internal accumulator in case of a power failure.
Channel LEDs  3-color LEDs per channel for:
   • overload condition
   • under load condition
   signal level in nominal range
Data memory
   2 GB Flash memory depending on model
Memory model
   Linear
Interfaces
   Ethernet (100MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232
Baud rate for RS 232
   9600 Baud to 115 kBaud
Dimensions
   325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D)
Weight
   appr. 4.9 kg; 10.8 lbs. (without accessories)
Warranty
   2 years
Calibration interval
   1 year recommended for Class-A, otherwise 2 years

 

Signal Conditioning
Range for 50 Hz systems
   50 Hz ± 15 % (42.5 Hz to 57.5 Hz)
Range for 60 Hz systems
   60 Hz ± 15 % (51 Hz to 69 Hz)
Resolution
   16 ppm
Sampling frequency for 50 Hz power frequency
   10.24 kHz, The sampling rate is synchronized to mains frequency.
Uncertainty for frequency measurements
   < 20 ppm
Uncertainty of internal clock
   < 1s / day
Measurement intervals
   Aggregation of the interval values as per IEC 61000-4-30 Class-A
Min-, Max-values:  Half cycle, e.g.: 10 ms rms values at 50Hz
Transients:  Sample rate 100 kHz to 10 MHz per channel
Harmonics
   as per IEC 61000-4-7:2002: 200 ms
Flicker
   as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)

 

Measurement Inputs
Number of inputs
   8 galvanically isolated inputs for voltage and current measurements.
Sensor safety
   up to 600 V CAT IV depending on sensor
Basic safety
   300 V CAT III
Nominal voltage (rms)
   100 mV
Range (peak value)
   280 mV
Overload capacity (rms)
   1000 V, continuously
Voltage rise rate
   max. 15 kV / µs
Input resistance
   1 MΩ
Input capacitance
   5 pF
Input filter
   Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse.
   The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters.

 

Uncertainties
Uncertainty at reference conditions
   Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz
With Sensor 1000 V  0,1% at Udin = 480 V and 600 V P-N
Sensor 600 V  0,1% at Udin = 230 V P-N
Intrinsic uncertainty for harmonics
   Class I as per EN 61000-4-7:2002
Reference conditions
   23 °C ± 2 K < 60 % rH; 74 °F ± 2 K < 60 % rH
   Warmed up instrument > 3h
   Power supply: 100 V to 250 V ac
Temperature drift
   100 ppm / K
Aging
   < 0.05 % / year
Common mode rejection
   > 100 dB at 50 Hz
Temperature drift
   Change of amplification through temperature: < 0.005 %/K
Aging
   Change of amplification due to ageing: < 0.04 %/year
Noise
   Noise voltage, input short-circuited: < 40 µV
DC
   ± (0.2% rdg + 0.1% sensor)

Description

Fluke 1760 Three Phase Power Quality Recorder

Class-A compliance for the most demanding power quality tests


The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.


Key Features:

  • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
  • GPS time synchronization: Correlate data with events or datasets from other instruments with precision
  • Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
  • Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
  • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
  • 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
  • Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
  • Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
  • Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions


Product Feature Fluke 1760 Basic Fluke 1760TR Basic Fluke 1760 Fluke 1760TR
Power quality statistics according to EN50160
Voltage event list (dips, swells and interruptions)
Continuous recording of:
Voltage
Current
Power P, Q, S
Power factor
kWh
Flicker
Unbalance
Frequency
Voltage and current harmonics to the 50th / Interharmonics
THD
Mains signaling
Triggered recordings
Online mode (Oscilloscope, transients and events)
Fast transient analysis up to 10 MHz    
4, 600V voltage probes    
4 dual-range flexible current probes (1000 A / 200 A ac)    
GPS time sync receiver    
Memory 2 GB Flash memory


Typical Applications:

Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.

Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.

Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.

Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output.

Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.


Model Name Description
Fluke 1760 Basic

Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:

  • Internal Flash-memory 2 GB
  • PQ Analyze software on CD-ROM
  • Ethernet cable for network connection (1)
  • Crosslink Ethernet cable for direct PC connection (1)
  • Mains cable (1)
  • Operational manuals
  • Carrying bag
Fluke 1760TR Basic

Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:

  • Internal Flash-memory 2 GB
  • PQ Analyze software on CD-ROM
  • Ethernet cable for network connection (1)
  • Crosslink Ethernet cable for direct PC connection (1)
  • Mains cable (1)
  • Operational manuals
  • Carrying bag
  • Fast transient analysis up to 10 MHz
Fluke 1760

Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:

  • Internal Flash-memory 2 GB
  • PQ Analyze software on CD-ROM
  • Ethernet cable for network connection (1)
  • Crosslink Ethernet cable for direct PC connection (1)
  • Mains cable (1)
  • Operational manuals
  • Carrying bag
  • Voltage probes, qty 4 (600 V for INTL set, 1000 V for US set)
  • Current probes, qty 4 (Dual-range flexible current probes 1000 A / 200 A AC)
  • GPS time sync receiver
Fluke 1760TR

Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:

  • Internal Flash-memory 2 GB
  • PQ Analyze software on CD-ROM
  • Ethernet cable for network connection (1)
  • Crosslink Ethernet cable for direct PC connection (1)
  • Mains cable (1)
  • Operational manuals
  • Carrying bag
  • Fast transient analysis up to 10 MHz
  • Voltage probes, qty 4 (600 V for INTL set, 1000 V for US set)
  • Current probes, qty 4 (Dual-range flexible current probes 1000 A / 200 A AC)
  • GPS time sync receiver



Features & Specification

More Information
Key Features Three Phase, Includes Flexi Clamps, Software included, Data Logging, AC/DC Current, GPS Synchronization
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Overview of Measurement Functions
Statistical Evaluation
   Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI
Event List
   Dips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list.
   The Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis.
   RMS values, transients and fast transients can be stored if a trigger fires.
Continuous Recording
   Fluke 1760 records rms values together with corresponding minimum and maximum values for:
   • Voltage
   • Current
   • Power P, Q, S
   • Power Factor
   • kWh
   • Flicker
   • Unbalance
   • Frequency
   • Harmonics/Interharmonics
   continuously with the following time aggregations:
   Day
   10 min
   Free Interval, e.g.: 15 min, 2h
Triggered Recordings
rms:  Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
   Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency.
   Basic aggregation for harmonics and interharmonics is 200ms
Oscilloscope:  Sample rate is 10.24 kHz for all 8 channels
Fast Transients:  Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients
Mains Signalling
   Phases and N-conductor, Voltage and current
Online Mode
   Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.

 

General Data
Intrinsic uncertainty
   refers to reference conditions and is guaranteed for two years
Quality system
   developed, manufactured as per ISO 9001: 2000
Environment conditions
Operating temp. range:  0 °C to +50 °C; 32 °F to +122 °F
Working temp. range:  -20 °C to +50 °C; -4 °F to +122 °F
Storage temp. range:  20 °C to +60 °C; -4 °F to 140 °F
Reference temperature:  23 °C ± 2 K; 74 °F ± 2 K
Climatic class:  B2 (IEC 654-1), -20 °C to +50 °C; -4 °F to +122 °F
Max. operating altitude:  2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II 
* depending on sensor
Reference conditions
Environment temp.:  23 °C ± 2 K ; 74°F ± 2 K
Power supply:  230 V ± 10 %
Power frequency:  50 Hz / 60 Hz
Signal:  declared input voltage Udin
Averaging:  10 minute intervals
Housing
   insulated, robust plastics housing
EMC
Emission:  Class-A as per IEC/EN 61326-1
Immunity:  IEC/EN 61326-1
Power supply
Range:  AC: 83 V to 264 V, 45 to 65 Hz
   DC: 100 V to 375 V
Safety:  IEC/EN 61010-1 2nd edition
   300 V CAT III
Power consumption:  max. 54VA
Battery pack:  NIMH, 7.2 V, 2.7 Ah
   In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.
Display
   Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.
Power LED:  • Permanent light: normal power supply from mains.
   • OFF: supply via internal accumulator in case of a power failure.
Channel LEDs  3-color LEDs per channel for:
   • overload condition
   • under load condition
   signal level in nominal range
Data memory
   2 GB Flash memory depending on model
Memory model
   Linear
Interfaces
   Ethernet (100MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232
Baud rate for RS 232
   9600 Baud to 115 kBaud
Dimensions
   325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D)
Weight
   appr. 4.9 kg; 10.8 lbs. (without accessories)
Warranty
   2 years
Calibration interval
   1 year recommended for Class-A, otherwise 2 years

 

Signal Conditioning
Range for 50 Hz systems
   50 Hz ± 15 % (42.5 Hz to 57.5 Hz)
Range for 60 Hz systems
   60 Hz ± 15 % (51 Hz to 69 Hz)
Resolution
   16 ppm
Sampling frequency for 50 Hz power frequency
   10.24 kHz, The sampling rate is synchronized to mains frequency.
Uncertainty for frequency measurements
   < 20 ppm
Uncertainty of internal clock
   < 1s / day
Measurement intervals
   Aggregation of the interval values as per IEC 61000-4-30 Class-A
Min-, Max-values:  Half cycle, e.g.: 10 ms rms values at 50Hz
Transients:  Sample rate 100 kHz to 10 MHz per channel
Harmonics
   as per IEC 61000-4-7:2002: 200 ms
Flicker
   as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)

 

Measurement Inputs
Number of inputs
   8 galvanically isolated inputs for voltage and current measurements.
Sensor safety
   up to 600 V CAT IV depending on sensor
Basic safety
   300 V CAT III
Nominal voltage (rms)
   100 mV
Range (peak value)
   280 mV
Overload capacity (rms)
   1000 V, continuously
Voltage rise rate
   max. 15 kV / µs
Input resistance
   1 MΩ
Input capacitance
   5 pF
Input filter
   Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse.
   The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters.

 

Uncertainties
Uncertainty at reference conditions
   Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz
With Sensor 1000 V  0,1% at Udin = 480 V and 600 V P-N
Sensor 600 V  0,1% at Udin = 230 V P-N
Intrinsic uncertainty for harmonics
   Class I as per EN 61000-4-7:2002
Reference conditions
   23 °C ± 2 K < 60 % rH; 74 °F ± 2 K < 60 % rH
   Warmed up instrument > 3h
   Power supply: 100 V to 250 V ac
Temperature drift
   100 ppm / K
Aging
   < 0.05 % / year
Common mode rejection
   > 100 dB at 50 Hz
Temperature drift
   Change of amplification through temperature: < 0.005 %/K
Aging
   Change of amplification due to ageing: < 0.04 %/year
Noise
   Noise voltage, input short-circuited: < 40 µV
DC
   ± (0.2% rdg + 0.1% sensor)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA