Time Electronics 1007 DC Millivolt Potentiometer & Calibrator
Output |
0 to 999.9mV in 3 ranges: |
Accuracy |
± 0.02% of setting + ± 0.02% of range + ± 1µV. |
Output Resistance |
Less than 0.2Ω on 1 V and 100 mV ranges. 1Ω on 10mV range. |
Maximum Output Current |
1V and 100mV ranges = 20mA. 10mV range = Up to short circuit value although it should be noted that loads of less than 1kΩ will give greater than 0.1% error. |
Output Voltage Stability |
Less than 60ppm/°C. Less than 100ppm per 3 months (non-cumulative). |
Output Polarity |
Positive or negative switch selected. A centre ‘off’ position is also provided. |
Output Noise Level |
Less than 30ppm of full scale |
Reference Source |
Precision zener diode, selected for stability and low temperature coefficient. |
Maximum Overload |
The instrument can withstand continuous short circuit on the output for all ranges. |
Null Balance Display |
On a front panel meter, zero and sensitivity controls are provided: |
Power Supply |
6-AA size (51x14mm) batteries. A battery condition display indicates when the batteries should be changed. An alternative power source is 6 NiMH cells of the same dimensions. These can be recharged via a socket on the top of the unit. The 6 rechargeable batteries and mains recharger are available as an optional extra. |
Operating Temperature |
-10°C to +60°C |
Dimensions |
H200 x W75 x D110mm (H215 x W100 x D120mm including protective cover) |
Weight |
0.75kg (1.2kg including protective cover) |
Supplied With | Protective cover (fitted), 6 x AA batteries (installed), and user manual |
Optional Extras |
Carry case, rechargeable battery pack (240V or 110V mains), and calibration certificates traceable to NPL and UKAS |
Description
The 1007 is a handheld calibrator that can be used for potentiometric voltage measurement in addition to its operation as a millivolt source.
The null zero and sensitivity are adjustable via front panel controls. Maximum sensitivity enables null balance to resolve 3 microvolt.
Three output ranges are provided to give adjustable output values from 1μV to 1V with a basic 0.02% accuracy. For signal injection, the operator needs to switch on, check the battery condition, select the range, and set the required voltage using the thumbwheel switches. The 1007 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output.
Power is provided by 6 AA batteries. Battery life is several months, depending on usage. The battery condition is monitored by an indicator mounted on the top of the unit. The 1007 has up to 20mA drive current and is short circuit and overload protected. An off/normal/reverse output polarity switch is provided.
A handheld calibrator that can be used for potentiometric voltage measurement in addition to its operation as a millivolt source, with 3 ranges from 1µV to 1V and 0.02% accuracy.
• 3 ranges up to 1V
• Accuracy 0.02% of setting + 0.02% of range
• 20mA output current
• Powered by 6 x AA batteries
• Best resolution 1µV
• Safety terminals
• LED null measuring facility
• Fitted with removable protective boot
• 100 hours typical battery life
• Short circuit and overload protected
• Optional carry case
• Optional calibration certificates
• 215 x 100 x 120mm / 1.2kg
Safety Terminals
Fitted as standard and fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.
Added Protection
The 1007 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and openings at the top and bottom to allow access to the battery meter and a position to place labels if required. It is easy to remove if the user prefers a stand-alone unit or to house the 1007 in the 9027 carry case.
Applications
Suitable for calibration and simulation of thermocouples. Accurate voltages equivalent to the output from a thermocouple can easily be set on the 1007, enabling fast calibration of temperature measuring equipment.
Alternatively, the 1007 can measure thermocouples output by operating as a potentiometer. Other applications include chart recorder calibration, A/D converter and DMM calibration, and use as a stable voltage for backing off DC offsets.
The 1007 is an easy to use test instrument designed for accuracy and reliability. As part of the Time Electronics portable calibration equipment range it is ideal for use in the lab or field.
Features & Specification
Key Features | 3 Ranges, Output Current 20mA, 0.02% Accuracy, Safety Terminals | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||
Manufacturer | Time Electronics | ||||||||||||||||||||||||||||||||
Short Description |
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA