Display: 3½ digit liquid crystal display (LCD) reading up to 1999.

Sampling Rate: 3 times per second.

Battery: Single 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22, PP3.

Battery Life: 200 hours typical with carbon-zinc.

Supplied Probe: 4-foot type “K” thermocouple bead (Teflon insulated)

Temperature Scale: Celsius or Fahrenheit user-selectable.

Resolution: 1°C or 1°F (or 0.1°C or 0.1°F) user-selectable.

Inputs: K-type thermocouples.

Measurement Range: -50°C to 1300°C (-58°F to 2000°F).

Meter Operating Range: For use in 0°C to 50°C environment.

Accuracy of Thermometer:

(18°C to 28°C ambient).

±(0.3% rdg + 1°C) -50°C to 1000°C.

±(0.5% rdg + 1°C) 1000°C to 1300°C.

±(0.3% rdg + 2°F) -58°F to 2000°F.

Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C.

Maximum Input: 60V DC or 24V rms AC.

TT5K Air probe:

Designed for measuring temperature of air and heating ducts. Maximum temperature: 250°C.

TT8K Surface probe:

Designed for measuring temperature of pipes and other surfaces. Maximum temperature: 600°C.

TT10K Pipe probe:

Designed for use on heating/ventilation applications and measuring in/out temperature of radiators and boilers. Maximum temperature: 100°C.

Description

Martindale THERMOKIT Thermometry Kit


The Martindale Thermokit is a comprehensive temperature kit, ideal for electricians, plumbers, boiler engineers and maintenance engineers. Supplied in a durable aluminium carry case, the kit includes the Martindale DT75 dual input thermometer, bead type probes, pipe clamp probes, an air probe and a surface probe.

This is a high quality dual-input digital thermometer with temperature difference capability. It is able to measure input and output temperature and temperature differentials through boilers, radiators etc. and can accept a wide range of K type probe accessories.

The meter comes with a protective rubberised holster and is switchable between °C and °F and between 1° and 0.1° resolution. Hold and maximum buttons allow the current value to be frozen or the maximum reading to be stored.

This kit includes:

  • 1 x DT75 Digital Thermometer
  • 1 x TT5K Air Probe
  • 1 x TT8K Surface Probe
  • 2 x TT10K Pipe Clamp Probes
  • 1 x Carry Bag
  • 2 x TT1KF Bead Type Probes

 

ISSWWW and Martindale Electric

Founded in 1928 and also owns Edgcumbe Instruments Metrohm® products, as well as the John
Drummond Engineers range of test lamps. They are a British owned company, based in Watford, just 5 minutes from junction 5 of the M1. Their product range helps electricians and maintenance engineers carry out portable appliance testing, check fixed wiring for 17th Edition and Part P testing, safely prove dead, and measure everything from light and sound levels to microwave leakage and power consumption.We are proud to be able to offer Martindale's products and services and have done so for many years.

Features & Specification

More Information
Key Features -50˚C and 1350˚C, Complete With Probes, Differential Temperature, Type K Connection, LCD Display, Displays Temperature in °C or °F
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Martindale
Short Description

SPECIFICATIONS

Display: 3½ digit liquid crystal display (LCD) reading up to 1999.

Sampling Rate: 3 times per second.

Battery: Single 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22, PP3.

Battery Life: 200 hours typical with carbon-zinc.

Supplied Probe: 4-foot type “K” thermocouple bead (Teflon insulated)

Temperature Scale: Celsius or Fahrenheit user-selectable.

Resolution: 1°C or 1°F (or 0.1°C or 0.1°F) user-selectable.

Inputs: K-type thermocouples.

Measurement Range: -50°C to 1300°C (-58°F to 2000°F).

Meter Operating Range: For use in 0°C to 50°C environment.

Accuracy of Thermometer:

(18°C to 28°C ambient).

±(0.3% rdg + 1°C) -50°C to 1000°C.

±(0.5% rdg + 1°C) 1000°C to 1300°C.

±(0.3% rdg + 2°F) -58°F to 2000°F.

Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C.

Maximum Input: 60V DC or 24V rms AC.

TT5K Air probe:

Designed for measuring temperature of air and heating ducts. Maximum temperature: 250°C.

TT8K Surface probe:

Designed for measuring temperature of pipes and other surfaces. Maximum temperature: 600°C.

TT10K Pipe probe:

Designed for use on heating/ventilation applications and measuring in/out temperature of radiators and boilers. Maximum temperature: 100°C.

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA