Fluke 6200-UK Portable Appliance Tester Kit 4377198
Specifications |
||
Test Specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75 % RH. | |
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
Power-on Test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
Display Range | 90 V to 264 V | |
Accuracy at 50 Hz | ± (2% + 3 counts) | |
Resolution | 1 V | |
Input Impedance | > 1 MΩ // 2.2 nF | |
Maximum Input Mains Voltage | 264 V | |
Earth Bond Test (Rpe) | Display Range | 0 to 19.99 Ω |
Accuracy (After Bond Test Zeroing) | ± (2.5% + 4 counts) | |
Resolution | 0.01 Ω | |
Test Current | 200 mA AC -0% +40% into 1.99 Ω 25 A AC ± 20% into 25 mΩ at 230 V |
|
Open Circuit Voltage | > 4 V AC, < 24 V AC | |
Bond Test Zeroing | can subtract up to 1.99 Ω | |
Insulation Test (Riso) | Display Range | 0 to 299 MΩ |
Accuracy | ± (5% + 2 counts) from 0.1 to 300 MΩ | |
Resolution | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
Test Voltage | 500 V DC -0% + 10% at 500 kΩ load | |
Test Current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
Auto Discharge Time | < 0.5 s for 1 μF | |
Max. Capacitive Load | Operational up to 1 μF | |
Touch Current Test | Display Range | 0 to 1.99 mA AC |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.01 mA | |
Internal Resistance (via Probe) | 2 kΩ | |
Measuring Method | Probe* | |
Substitute Leakage Current Test | Display Range | 0 to 19.99 mA AC |
Accuracy | ± (2.5% + 3 counts) | |
Resolution | 0.01 mA | |
Test Voltage | 100 V AC ± 20% | |
Load/Leakage Test: Load Current | Display Range | 0 A to 13 A |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.1 A* | |
Load/Leakage Test: Load Power | Display Range 230 V Mains | 0.0 VA to 3.2 kVA |
Accuracy | ± (5 % + 3 counts) | |
Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
Load/Leakage Test: Leakage Current | Display Range | 0 to 19.99 mA |
Accuracy | ± (4% + 4 counts) | |
Resolution | 0.01 mA* | |
PELV Test | Accuracy at 50 Hz | ± (2% + 3 counts) |
Overload Protection | 300 V rms | |
Warning Threshold | 25 V rms | |
*The appliance under test is energized at mains potential. |
Environmental Specifications |
|
Operating Temperature | 0 to 40 °C |
Relative Humidity | Non condensing < 10 °C 95% from 10 to 30 °C 75% from 30 to 40 °C |
Safety Specifications |
|
Safety Rating | Complies with EN61010-1 3rd edition |
CAT II, 300 V, pol 2 |
Mechanical & General Specifications |
||
Size | 200 mm (L) x 275 mm (W) x 114 mm (H) | |
Weight | 3.13 kg | |
Power Supply | 230 V +10 % -15 %, 50 Hz ±2 | |
Power Consumption (Tester) | 13 W typical (idle) 60 W max. during 25A Bond test |
|
Storage | Temperature | -10 to 60 °C |
Corrosion | 70 °C @ 95 % RH for 5 days max. | |
Operating Altitude | 0 up to 2000 m | |
Sealing | IP-40 (enclosure), IP-20 (connectors) | |
EMC | Complies with EN61326-1, portable | |
EMI Immunity | 3 V/m |
Description
For a limited time ISSWWW are offering you FREE quality PAT accessories with purchases of selected
PAT testers and PAT testing kits. Simply make your selection from the drop down box below to add your bundle.
*Choose from the following:
-
Option 1) Kewtech PATLOG1 PAT Register & a set of 500 PASS and 200 FAIL labels
-
Option 2) Seaward 270A076 110V PAT adapter
-
Option 3) Kewtech KT111 fully auto-ranging Multimeter
-
Option 4) Kewtech 103 Audible Socket Tester and a Kewtech R2 Socket Testing Adapter
Fluke 6200-2 UK PAT Starter Kit
Perform More Tests Each Day
The Fluke 6200-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6200-2 is designed to enable you to work faster without compromising safety – yours or your customer’s.
Fluke 6200-2 UK Starter Kit comes supplied with:
- 6200-2 Portable appliance tester
- IRP1, Register For Pat ( Log Book )
- EXTL 100, Extension Lead Test Adaptor
- FAIL250, Label
- Pass 560R, Appliance Pass Labels, A5 sheet round
One-Touch Solution
Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working.
Low Weight
Weighing approximately 3 kg, the 6200-2 is lightweight and easy to carry when working on-site. The hard rugged carrying case (supplied) not only offers protection during transit but also includes extra storage space for accessories and other tools.
Small Size
This portable appliance testers is also extremely compact, and has Fluke’s traditional ruggedness to be able to withstand working in the field. Packed with all the features you need for testing portable appliances, a Fluke PAT tester is a complete all-in-one solution.
Fluke Simplifies Portable Appliance Testing
- Dedicated key for each test for ‘one-touch’ testing
- Pre-set pass/fail levels to save time
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC socket for easy mains/extension lead testing
- Detachable test leads for quick field replacement
- Integral carrying handle
- USB port for data transfer
Features & Specification
Key Features | Manufacturer Certificate Included, Entry level PAT kit, Pass and fail labels included, Memory Function | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Fluke Testers | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.