Chauvin Arnoux CA6471 Earth Tester
Chauvin Arnoux CA6471 Earth Tester | ||
CA6471 | ||
Specifications | ||
Earth resistance measurement with 2 clamps |
Range | 0.01 Ω to 500 Ω |
Resolution | 0.01 Ω to 1 Ω | |
Measurement frequency | Auto: 1367 Hz ; Manual: 128 Hz - 1367 Hz - 1611 Hz - 1758 Hz | |
Earth resistance 3-Pole method |
Range | 0.01 Ω to 99.99 kΩ |
Resolution | 0.01 Ω to 100 Ω | |
Test voltage | 16 V or 32 Vrms rated voltage, selectable by user | |
Measurement frequency | 41 Hz to 512 Hz, automatic or manual | |
Test current | Up to 250 mA | |
Accuracy | ±2 % L + 1 count to 128 Hz | |
Earth resistance 4P measurements / 4P + measurements with clamps |
Range | 0.001 Ω to 99.99 kΩ |
Resolution | 0.001 Ω to 100 Ω | |
Test voltage | 16 V or 32 V selectable | |
Measurement frequency | 41 Hz to 512 Hz automatic or manual | |
Test current | Up to 250 mA | |
Accuracy | ±2 % of value ±1 count | |
Soil resistivity measurement |
Measurement method | Wenner or Schlumberger method with automatic calculation of results and display in Ω-metres or Ω-feet |
Range (Automatic selection) | 0.01 Ω to 99.99 kΩ ; ρ max. 999 kΩm | |
Resolution | 0.01 Ω to 100 Ω | |
Test Voltage | 16 V or 32 V, selectable | |
Measurement frequency | 41 Hz to 512 Hz selectable | |
External voltage measurement |
Range (automatic selection) | 0.1 to 65.0 VAC/DC – DC to 450 kHz |
Accuracy | ±2 % R + 1 count | |
Resistance measurement/ continuity and bounding |
Type of measurement | 2 wire or 4 wire method, selectable by user |
Range (automatic selection) | 2 wire: 0.01 Ω to 99.9 kΩ – 4 wire: 0.001 Ω to 99.99 kΩ | |
Accuracy | ±2 % R + 2 counts | |
Test voltage | 16 VDC (polarity +, - or auto) | |
Test current | > 200 mA max. for R < 20 Ω | |
Data storage | Storage capacity | 512 test results |
Communication | Optically-isolated USB | |
Other Features | ||
Power Supply | Rechargeable battery | |
Battery charger power supply | External power supply with 18 Vdc / 1.9 A output or 12 Vdc vehicle power supply | |
Electrical Safety | 50 V CAT IV | |
Dimmensions / Weight | 272 x 250 x 128 mm / 3 kg |
Description
Chauvin Arnoux CA6471 Earth Tester
Earth tester offering selective earth, soil resistivity, earth coupling, and continuity measurements
Ergonomic, comprehensive, and accurate, the CA6471 offers direct access to all the measurements on the front panel using a rotary switch. Compact because it has been designed for on-site use, the CA6471 is rugged and leakproof. To simplify connection, the 4 terminals for connecting the stakes are colour-coded to help identify them.
The C.A 6471 includes a large backlit LCD screen and a battery that is rechargeable with an external charger connected to the mains or to a vehicle cigarette lighter. It is also equipped with a function for direct, ordered storage of the measurement results. A USB communication output can be used to export the data onto a PC to process them with the Ground Tester Transfer software.
Specifications:
The CA6471 guarantees the reliability of measurements carried out by:
- traditional stake-based methods
- self-diagnosis when each measurement starts, so that any faults liable to affect the measurements (bad connections or presence of disturbance signals) are indicated
- extensive measurement ranges: 0.001 Ω to 100 kΩ
- adjustment of the measurement frequency between 41 Hz and 512 Hz (3P & 4P measurements)
The CA6471 is equipped with advanced expert calculation functions:
- for earth coupling measurements, simply perform the 3 successive measurements required and the tester then calculates the coupling coefficient automatically
- for soil resistivity measurements, simply program the distances used for the measurement and the instrument automatically calculates r using the Wenner or Schlumberger methods.
Other specifications:
- Power supply: NiMh rechargeable battery with an external charger
- IP53 protection
- Compliant with IEC 61557 -1 -4 -5
- Safety: IEC 61010 50V CAT IV
- Dimensions: 272 x 250 x 128 mm, 3 kg
isswww and Chauvin Arnoux
The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.
Features & Specification
Key Features | Memory Function, Downloadable, Rechargeable, 4 pole testing, Backlit Display, One Button Operation, High Accuracy | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Chauvin Arnoux | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
Product Stock Status |
Next Day Delivery (subject to availability) |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|