Beha Amprobe ACDC-100 1000 A AC/DC Clamp Meter

£150.60

Amprobe ACDC-100 Clamp Meter Specifications

FEATURE ACDC-100 ACDC-100 TRMS
True-rms
AC Current 400.0 A, 800 A
DC Current 400.0 A, 1000 A
Voltage AC/DC 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V
Resistance 400.0 O, 4.000 kO, 40.00 kO, 400.0 kO, 4.000 MO, 40.00 MO
Continuity
Capacitance 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 3000 µF
Accommodates conductors up to 2.0 (50 mm) in diameter
Specifications
True-rms N/A
DC Current 400.0 / 1000 A Accuracy: +/-(1.5% Rdg + 4 LSD) @ 0 to 800 A
AC Current 400.0 / 800 A Accuracy: +/-(1.5% Rdg + 5 LSD) @ 0 to 600 A, 40 to 100 Hz
AC Voltage 400.0 mV 4.000 / 40.00 / 400.0 / 600 V Accuracy: +/-(1.5% Rdg + 4 LSD) @ 4 V to 400V  ranges , 50 to 500 Hz
DC Voltage 400.0 mV 4.000 / 40.00 / 400.0 / 600 V Accuracy: +/-(0.5% Rdg + 3 LSD) @ 4 V to 400 V ranges
Resistance 400.0 Ohms 4.000 / 40.00 / 400.0 kOhms 4.000 / 40.00 MOhms Accuracy: +/-(0.6% Rdg + 4 LSD) @ 4 to 400 kOhms ranges
Capacitance 500.0 nF / 5.000 / 50.00 / 500.0 / 3000 uF Accuracy: +/-(3.5% Rdg + 6 LSD)

Description

Beha Amprobe ACDC-100 1000 A AC/DC Clamp Meter

Where accuracy, quality, and the newest technology meet. The ACDC100 offers superior AC/DC measurement capabilities, highest product quality and enhanced ergonomic design.

 

Amprobe ACDC-100 Comes Supplied With:

  • ACDC-100
  • Deluxe carrying case
  • Test leads
  • Batteries (installed)

Key Features:

  • Large, easy to read LCD display
  • Auto and manual ranging
  • Relative zero mode
  • Auto power off
  • Data hold
  • MAX capture function for inrush current measurements (30 mS response)
  • Diode test
  • Audible continuity
  • Accommodates conductors up to 2.0″ (50 mm) in diameter
  • “Third hand” – test probe holder
  • Rubber over-molded case with built-in probes storage

Available with TRMS and Display Backlight The ACDC-100 TRMS version addresses the needs of professionals who rely on performance and reliability. A large LCD for easy viewing. Simplified Interface
These full function clamp-ons have simplified interfaces to help your customers get their work done quickly. Easy-to-read oversize display screens feature the large digits. Each meter offers auto and manual ranging along relative zero mode functions.

      

ISSWWW and Beha-Amprobe - A Fluke Company

With a combined experience of over 100 years, well-known German brand Beha and US-based Amprobe have a track record to be proud of. Now we have joined forces, and together we are committed to making your job safer, faster and easier than ever. Our expertise is legendary. Almost 70 years ago in 1948, we invented the very first clamp meter, and we haven’t stopped innovating since.
The Amprobe brand has always remained a staple among our stockholding. It's pedigree and price point make the brand a quality offering that rival higher priced brands for comparable technology. You can trust Amprobe, thousands do. From multimeters to voltage detectors, at Beha-Amprobe we constantly improve our designs to provide you with the very best quality tools and support.

Features & Specification

More Information
Key Features 51mm Jaw Size, Automatic AC / DC detection, Large LCD Display, Resistance/audible continuity, Ruggedised Build, Tests up to 1000A, Diode Testing
Manufacturer Amprobe
Short Description

Amprobe ACDC-100 Clamp Meter Specifications

FEATURE ACDC-100 ACDC-100 TRMS
True-rms
AC Current 400.0 A, 800 A
DC Current 400.0 A, 1000 A
Voltage AC/DC 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V
Resistance 400.0 O, 4.000 kO, 40.00 kO, 400.0 kO, 4.000 MO, 40.00 MO
Continuity
Capacitance 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 3000 µF
Accommodates conductors up to 2.0 (50 mm) in diameter
Specifications
True-rms N/A
DC Current 400.0 / 1000 A Accuracy: +/-(1.5% Rdg + 4 LSD) @ 0 to 800 A
AC Current 400.0 / 800 A Accuracy: +/-(1.5% Rdg + 5 LSD) @ 0 to 600 A, 40 to 100 Hz
AC Voltage 400.0 mV 4.000 / 40.00 / 400.0 / 600 V Accuracy: +/-(1.5% Rdg + 4 LSD) @ 4 V to 400V  ranges , 50 to 500 Hz
DC Voltage 400.0 mV 4.000 / 40.00 / 400.0 / 600 V Accuracy: +/-(0.5% Rdg + 3 LSD) @ 4 V to 400 V ranges
Resistance 400.0 Ohms 4.000 / 40.00 / 400.0 kOhms 4.000 / 40.00 MOhms Accuracy: +/-(0.6% Rdg + 4 LSD) @ 4 to 400 kOhms ranges
Capacitance 500.0 nF / 5.000 / 50.00 / 500.0 / 3000 uF Accuracy: +/-(3.5% Rdg + 6 LSD)
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA