Amprobe 2100 Series Technical Specifications

 

2100-Alpha

2100-Beta 2100-Gamma

Voltage Test

LED Voltage Range

12…690 V AC/DC

12…690 V AC/DC

12…≥690 V AC/DC

LED Indicator

±12, ±24, 50, 120, 230, 400, 690 V

±12, ±24, 50, 120, 230, 400,  ≥690 V

LED Tolerances

acc. To EN 61243-3:2010

LCD Voltage Range

-

12…690 V AC/DC

6…1000 V AC/ 6…1200 V DC

LCD Resolution

-

1 V

LCD Tolerance

-

± (3% rdg + 3 LSD)

LED and LCD Response Time

< 1s

Frequency Range

DC,  16 2/3 Hz…400 Hz

Acoustic Indication

≥ 50 V AC, ≥ 120 V DC

Voltage Detection

Automatic (AC/DC)

Polarity Detection

Full Range

Range Detection

Automatic

Current I

(load buttons not activated)

≤3.5 mA AC/DC at 690 V AC/DC

≤3.5 mAAC at 1000 VAC/ 4.5 mADC at 1200 VDC

Internal Load

(load buttons not activated)

Approximately 2.4 W at 690 V AC/DC

Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC

Test Current Switchable Load

(load buttons activated)

≤350 mA AC/DC at 690 V AC/DC

≤300 mAAC at 1000 VAC / ≤350 mADC at 1200 VDC

Switchable Load

(load buttons activated)

Approximately 240 W at 690 V AC/DC

Approximately 300 W at 1000 VAC / Approximately 420 W at 1200 VDC

Automatic Power ON

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LCD: >12V

LED: >12 V

LCD: > 6V

Trip Test RCD (earth leakage circuit breaker)

Test Current Switchable Load

(load buttons activated)

>30 mAAC at 230 VAC

Single Pole Phase Test

Voltage Range

180…690 VAC against earth

100…1000 VAC against earth

Frequency Range

40Hz… 70Hz

Acoustic Indication

Yes

Indication

Red LED

Continuity Test (Rx)/ Diode Test

Range

0….500 kΩ

Tolerance

0% to +50%

Test Current

<5 μA

Acoustic Indication

Yes

Diode Test

Yes

Indication

RED LED

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Automatic Power ON

< 500 kΩ

Phase Rotation Indication

Voltage Range

340…440 V AC phase to phase

170…1000 V AC phase to phase

Frequency Range

47…63 Hz

40…70 Hz

Indication

Red LED

Resistance Measurement (Ω)/ Low Resistance Indication (2100-Gamma only)

Resistance Range on LCD

0….1999 Ω

Resolution

1 Ω

Tolerance

± (5% rdg + 10 LSD) at 20°C

Temperature Coefficient

± (5 LSD / 10 K)

Test Current

<30 μA

Low Resistance Indication

Acoustic Indication <10…50Ω

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Non-Contact Voltage Indication/ Electric Field (NCV/EF)

Voltage Range

-

100…1000 VAC

Frequency Range

-

50…60 Hz

Indication

_

3 levels shown by LCD segments

Data Hold

Data Hold

_

Only voltage measurements (12…690V AC/DC)

Voltage and resistance measurements, NCV

Measurement Illumination Area/ Torch Light

Torch Light

White LED

General Specifications

Operation Time (DT)

30s

Recovery Time

240s

Operating Temperature

-15°C to +55°C

Storage Temperature

-15°C to +55°C

Humidity

Max. 95% RH

Operating Altitude

Up to 2000m

Safety Rating (Overall Voltage Category)

CAT IV / 600V, CAT III / 690V

CAT IV / 600V, CAT III / 1000V

Pollution Degree

2

Protection Degree

IP64

Safety Regulations

IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011

Approvals, Compliance

GS mark from TÜV Rheinland, CE

Power Supply

Battery 2 x 1.5V (AAA/ IEC LR03)

Power Consumption

Approximately 60mA

Battery Lifetime

More than 10000 measurements (<5 s/ per measurement)

Dimensions (HxWxD)

Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)

Weight

Approximately 320 g (0.71 lb)

Multibuy

Description

Beha-Amprobe 2100-Gamma 2 Pole Tester

Voltage tester with continuity measurement, phase sequence indication, resistance and NCV

Product Overview:

The Beha-Amprobe 2100-Alpha, 2100-Beta and 2100-Gamma are rugged and reliable two pole voltage testers for voltage and continuity checks. Built tough for use in industrial and commercial environments, the 2100 Series is safety rated up to CAT III 1000 V/ CAT IV 600 V and measures voltage range up to 1000 V AC and 1200 V DC (2100-Gamma only). Designed with reinforced components for dependable performance, the 2100 Series has an ingress protection degree of IP 64 and is built according to voltage tester standard EN 61243-3 and are TÜV and GS approved.

Key Features:

• Voltage test up to 1000 V, alternating current and 1200 V direct current
• Digital LCD 12…1000 V AC/ 1200 V DC
• Measures resistance up to 1999 Ohm
• Optical and acoustic continuity and voltage test
• Low resistance continuity measurement <10...50 Ohm
• Patented phase rotation indicator, no 3rd hand required
• Single-pole phase test
• Polarity
• Non-contact voltage (NCV/EF) detection

Product information
• Switchable load (load tester) of 300 W at 1000 VAC / 420 W at 1200 VDC via two push buttons, triggering a RCD/FI up to 30 mA
• IP 64, water and dust-resistant
• Integrated probe-tip protection for reducing the danger of injuries

Product highlights
• No unintentional triggering of RCD/FI circuit breakers
• Fast single-handed testing of power sockets with 19 mm contact clearance, without the probe coming away from the unit
• Lighting of measurement points via white LED
• Extremely robust construction with doubly insulated wires

Two Button Switchable Load/
RCD Trip Test

Long, durable test leads with wear indicator

Test probe protector cover with accessory storage 

When the two buttons are not pressed
the unit is in high impedance mode,
providing additional safety protection
when testing live power sources,
and avoiding accidental tripping of
residual-current devices (RCD). When
the buttons are pressed the unit is in
low impedance mode, eliminating inaccurate readings as result of ghost voltage. Additionally, in systems with RCDs you can press the buttons to intentionally trip 10 mA or 30 mA RCDs and determine if they are wired correctly.

Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.

Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.



ISSWWW and Beha-Amprobe - A Fluke Company

With a combined experience of over 100 years, well-known German brand Beha and US-based Amprobe have a track record to be proud of. Now we have joined forces, and together we are committed to making your job safer, faster and easier than ever. Our expertise is legendary. Almost 70 years ago in 1948, we invented the very first clamp meter, and we haven’t stopped innovating since.
The Amprobe brand has always remained a staple among our stockholding. It's pedigree and price point make the brand a quality offering that rival higher priced brands for comparable technology. You can trust Amprobe, thousands do.From multimeters to voltage detectors, at Beha-Amprobe we constantly improve our designs to provide you with the very best quality tools and support.

Features & Specification

More Information
Key Features Multibuy Deal Available, Voltage Range 6-1000V AC, Voltage Range 6-12000V DC, Non-contact voltage detector, LCD Display, GS38 Compliant, Phase Rotation Tester, LED Indicator, Indication of Polarity
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Amprobe
Short Description

Amprobe 2100 Series Technical Specifications

 

2100-Alpha

2100-Beta 2100-Gamma

Voltage Test

LED Voltage Range

12…690 V AC/DC

12…690 V AC/DC

12…≥690 V AC/DC

LED Indicator

±12, ±24, 50, 120, 230, 400, 690 V

±12, ±24, 50, 120, 230, 400,  ≥690 V

LED Tolerances

acc. To EN 61243-3:2010

LCD Voltage Range

-

12…690 V AC/DC

6…1000 V AC/ 6…1200 V DC

LCD Resolution

-

1 V

LCD Tolerance

-

± (3% rdg + 3 LSD)

LED and LCD Response Time

< 1s

Frequency Range

DC,  16 2/3 Hz…400 Hz

Acoustic Indication

≥ 50 V AC, ≥ 120 V DC

Voltage Detection

Automatic (AC/DC)

Polarity Detection

Full Range

Range Detection

Automatic

Current I

(load buttons not activated)

≤3.5 mA AC/DC at 690 V AC/DC

≤3.5 mAAC at 1000 VAC/ 4.5 mADC at 1200 VDC

Internal Load

(load buttons not activated)

Approximately 2.4 W at 690 V AC/DC

Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC

Test Current Switchable Load

(load buttons activated)

≤350 mA AC/DC at 690 V AC/DC

≤300 mAAC at 1000 VAC / ≤350 mADC at 1200 VDC

Switchable Load

(load buttons activated)

Approximately 240 W at 690 V AC/DC

Approximately 300 W at 1000 VAC / Approximately 420 W at 1200 VDC

Automatic Power ON

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LCD: >12V

LED: >12 V

LCD: > 6V

Trip Test RCD (earth leakage circuit breaker)

Test Current Switchable Load

(load buttons activated)

>30 mAAC at 230 VAC

Single Pole Phase Test

Voltage Range

180…690 VAC against earth

100…1000 VAC against earth

Frequency Range

40Hz… 70Hz

Acoustic Indication

Yes

Indication

Red LED

Continuity Test (Rx)/ Diode Test

Range

0….500 kΩ

Tolerance

0% to +50%

Test Current

<5 μA

Acoustic Indication

Yes

Diode Test

Yes

Indication

RED LED

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Automatic Power ON

< 500 kΩ

Phase Rotation Indication

Voltage Range

340…440 V AC phase to phase

170…1000 V AC phase to phase

Frequency Range

47…63 Hz

40…70 Hz

Indication

Red LED

Resistance Measurement (Ω)/ Low Resistance Indication (2100-Gamma only)

Resistance Range on LCD

0….1999 Ω

Resolution

1 Ω

Tolerance

± (5% rdg + 10 LSD) at 20°C

Temperature Coefficient

± (5 LSD / 10 K)

Test Current

<30 μA

Low Resistance Indication

Acoustic Indication <10…50Ω

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Non-Contact Voltage Indication/ Electric Field (NCV/EF)

Voltage Range

-

100…1000 VAC

Frequency Range

-

50…60 Hz

Indication

_

3 levels shown by LCD segments

Data Hold

Data Hold

_

Only voltage measurements (12…690V AC/DC)

Voltage and resistance measurements, NCV

Measurement Illumination Area/ Torch Light

Torch Light

White LED

General Specifications

Operation Time (DT)

30s

Recovery Time

240s

Operating Temperature

-15°C to +55°C

Storage Temperature

-15°C to +55°C

Humidity

Max. 95% RH

Operating Altitude

Up to 2000m

Safety Rating (Overall Voltage Category)

CAT IV / 600V, CAT III / 690V

CAT IV / 600V, CAT III / 1000V

Pollution Degree

2

Protection Degree

IP64

Safety Regulations

IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011

Approvals, Compliance

GS mark from TÜV Rheinland, CE

Power Supply

Battery 2 x 1.5V (AAA/ IEC LR03)

Power Consumption

Approximately 60mA

Battery Lifetime

More than 10000 measurements (<5 s/ per measurement)

Dimensions (HxWxD)

Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)

Weight

Approximately 320 g (0.71 lb)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA