Beha-Amprobe AMP-220 600V TRMS Clamp Meter

£143.94
FEATURE AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
AC voltage (True-rms) Range: 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz) ±0.8% + 5LSD (50 to 60 Hz)
DC voltage Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
AC+DC voltage Range: 0 to 600.0 V 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.2% + 7LSD (50 to 60 Hz) ±1.2% + 7LSD (50 to 60 Hz) ±1.0% + 7LSD (50 to 60 Hz) 
±1.8% + 7LSD (DC 40 to 200 Hz) 
±1.2% + 7LSD 200 to 400 Hz)
AC current Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (100 to 400 Hz)
DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.0% + 5LSD (DC 50 to 100 Hz) ±2.0% + 5LSD (DC 50 to 100 Hz) ±1.8% + 5LSD (DC 50 to 100 Hz)
AC+DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (40 to 100 Hz) 
±2.5% + 7LSD (100 to 400 Hz)
Precise low current AC Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)
Precise low current DC Range: 0 to 60.0 A 0 to 60.0 A 0 to 60.00 A
Accuracy: ±2.0% + 5LSD ±2.0% + 5LSD ±1.5% + 5LSD (0.00 to 20.00 A) 
±3.0% + 5LSD (>20.00 to 60.00 A)
Micro amps Range: 0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Frequency Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±2.0% + 4LSD (600 A range)
Resistance Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity beeper ON ≤ 10 Ω
Off > 250 Ω
Temperature* 
(Type K thermocouple)
  -40.0 to 752 °F
-40.0 to 400 °C
  ±1.0% + 3.0 °F (-40.0 to 14.0 °F) 
±1.0% + 1.5 °F (>40.0 to 99.9 °F) 
±1.0% + 2.0 °F (100 to 752 °F) 
±1.0% + 1.5 °C (-40.0 to 10.0 °C) 
±1.0% + 0.8 °C (>-10.0 to 99.9 °C) 
±1.0% + 1.0 °C (100 to 400 °C) 
Non-contact voltage 10 V to 1000 V AC (50 to 60 Hz)
Phase rotation indication   Rotation-R for main supply 
Rotation-M for motors
Diode test  
Jaw opening   1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Safty rating   CAT III 600 V CAT IV 600V 
CAT III 1000 V
Special Features
In-rush current  
Peak hold (Crest)  
Relative zero  
Max/Min/Avg  
Data hold  
Backlight  
Auto power off  
Work light  

*Error does not include Type-K thermocouple errors

For complete specs please download the product datasheet under the "Resources" tab.

Description

Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

With a full range of AC/DC current, AC/DC voltage, and frequency measurement functions for basic electrical troubleshooting, the AMP-220 clamp meter with its large backlit display is an excellent amp clamp meter choice. Rated CAT III 600 V, the AMP-210 clamp meter offers True-RMS sensing, fast response processor, non-contact voltage detection, capacitance, resistance and continuity measurements to enhance efficiency and safety in today’s complex electrical environments.

AMP-220 600A AC/DC TRMS Clamp Meter

  • True-RMS
  • Voltage up to 600 V AC/DC, Current up to 600 A AC/DC, resistance and frequency
  • Low pass filter for variable frequency drives
  • Amp-tip function for precise low current measurements down to the tenth of an Amp
  • Capacitance measurement for start and run motor capacitors
  • Non-contact voltage detection
  • Audible continuity and diode test
  • Data hold, relative zero
  • Large LCD backlit display
  • Accommodates conductors up to 1.37 in (35mm)
  • CAT III 600 V safety rated

Included Accessories: Test Leads, (2) AAA Batteries (installed), User Manual, Carrying Case

The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, enabling accurate current measurement of both large and small diameter wires. A low pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency).

  • Measures AC/DC Current to 600 A and AC/DC Voltage to 600 V
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Capacitance measurement, continuity beeper and diode test
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Offers data hold and relative zero for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • Backlit display for easy measurement viewing in bright and dim environments
  • Accommodates conductors up to 1.37 in (35mm)
  • Includes test leads, batteries (installed), carrying case, and user manual
  • CAT III 600 V safety rated

Features & Specification

More Information
Key Features Current AC/DC, TRMS, Data Hold, Resistance Measurement, Frequency Measurement, Voltage AC/DC, Backlit LCD Screen
Manufacturer Amprobe
Short Description
FEATURE AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
AC voltage (True-rms) Range: 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz) ±0.8% + 5LSD (50 to 60 Hz)
DC voltage Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
AC+DC voltage Range: 0 to 600.0 V 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.2% + 7LSD (50 to 60 Hz) ±1.2% + 7LSD (50 to 60 Hz) ±1.0% + 7LSD (50 to 60 Hz) 
±1.8% + 7LSD (DC 40 to 200 Hz) 
±1.2% + 7LSD 200 to 400 Hz)
AC current Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (100 to 400 Hz)
DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.0% + 5LSD (DC 50 to 100 Hz) ±2.0% + 5LSD (DC 50 to 100 Hz) ±1.8% + 5LSD (DC 50 to 100 Hz)
AC+DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (40 to 100 Hz) 
±2.5% + 7LSD (100 to 400 Hz)
Precise low current AC Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)
Precise low current DC Range: 0 to 60.0 A 0 to 60.0 A 0 to 60.00 A
Accuracy: ±2.0% + 5LSD ±2.0% + 5LSD ±1.5% + 5LSD (0.00 to 20.00 A) 
±3.0% + 5LSD (>20.00 to 60.00 A)
Micro amps Range: 0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Frequency Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±2.0% + 4LSD (600 A range)
Resistance Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity beeper ON ≤ 10 Ω
Off > 250 Ω
Temperature* 
(Type K thermocouple)
  -40.0 to 752 °F
-40.0 to 400 °C
  ±1.0% + 3.0 °F (-40.0 to 14.0 °F) 
±1.0% + 1.5 °F (>40.0 to 99.9 °F) 
±1.0% + 2.0 °F (100 to 752 °F) 
±1.0% + 1.5 °C (-40.0 to 10.0 °C) 
±1.0% + 0.8 °C (>-10.0 to 99.9 °C) 
±1.0% + 1.0 °C (100 to 400 °C) 
Non-contact voltage 10 V to 1000 V AC (50 to 60 Hz)
Phase rotation indication   Rotation-R for main supply 
Rotation-M for motors
Diode test  
Jaw opening   1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Safty rating   CAT III 600 V CAT IV 600V 
CAT III 1000 V
Special Features
In-rush current  
Peak hold (Crest)  
Relative zero  
Max/Min/Avg  
Data hold  
Backlight  
Auto power off  
Work light  

*Error does not include Type-K thermocouple errors

For complete specs please download the product datasheet under the "Resources" tab.

Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA