Beha-Amprobe 35XP-A Digital Multimeter
Amprobe 35XP-A Digital Multimeter | ||
---|---|---|
General Specs | ||
Display | 3-3/4 digit liquid crystal display (LCD) with maximum reading of 3999 | |
Polarity | Automatic, positive implied, negative polarity indication | |
Overrange | (OL) or (-OL) is displayed | |
Zero | Automatic | |
Low Battery Indication | Symbol displayed when battery voltage drops below operating level | |
Auto Power Off | Approx 10 minutes | |
Measurement Rate | 2 times per second, nominal | |
Operating Environment | 0 to 50°C at <70% RH | |
Storage Temperature | -20 to 60°C, 0 to 80% RH with battery removed from meter | |
Accuracy | Stated accuracy at 23°C ± 5°C <75% relative humidity | |
Temperature Coefficient | 0.1 x (specified accuracy) per °C (0 to 18°C, 28°C to 50°C) | |
Altitude | 2000m | |
Power | Single standard 9 volt battery, BEDA 1604, JIS 006P, IEC 6F22 | |
Battery Life | 150 hours typical with carbon-zinc, 300 hours typical with alkaline | |
Dimensions (H x W x D) | 155mm x 72mm x 32mm | |
Weight | Approx 400g including battery | |
Warranty | One year | |
Technical Specs | ||
Measurement Type | Range | Accuracy |
Voltage | ||
DC Volts | 400mV, 4V, 40V, 400V, 1000V | ± (0.5 % rdg + 1 dgt) |
AC Volts (45Hz to 500Hz) | 400mV (45 to 100Hz) 4V, 40V, 400V, 750V |
±(1.5% rdg + 5 dgts) ±(1.5% rdg + 5 dgts) |
Resolution | 100μV | - |
Input Impedance | 400mV: >100MΩ; 4V: 10MΩ; 40V to 1000V: 9.1MΩ | - |
Overload Protection | 1000V DC or 750V AC RMS | - |
Current | - | |
DC Current | 400μA, 4000μA, 40mA, 400mA 2A |
±(1.0 % rdg + 2 dgt) ± (2.0% + 3 dgts) |
AC Current | 400μA, 4000μA, 40mA, 400mA 2A |
± (1.5% rdg + 5 dgts) ± (2.5% rdg + 3 dgts) |
Resolution | 0.1μA | - |
Input Protection | 2A/1000V fast blow ceramic fuse 3.6mm x 32mm on A input | - |
Burden Voltage | 500mV max (2V on 4mA, 400mA ranges) | - |
Resistance | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ 40MΩ |
±(1.0% rdg + 4 dgts) ± (2.0% rdg + 5 dgts) |
Resolution | 100mΩ | |
Open Circuit Voltage | -0.45V DC typical (-1.2V DC on 400Ω range) | - |
Overload Protection | 1000V DC or 750V AC RMS | - |
Capacitance | 4nF, 40nF, 400nF, 4μF 40μF, 400μF 4mF |
± (5.0% rdg + 30 dgts) ± (5.0% rdg + 5 dgts) ± (5.0% rdg + 15 dgts) |
Resolution | 1pF | - |
Test Voltage | <1V | - |
Test Frequency | 1.3Hz on 4nF to 40μF ranges, 0.7Hz on 400μF, 4mF ranges | - |
Input Protection | 2A/1000V fast blow ceramic fuse 6.3mm x 32mm on A input | - |
Temperature | 400 °C, 1000 °C, 400 °F, 1832 °F -20 °C to 10 °C 10 °C to 200 °C 200 °C to 1000 °C -4 °F to 50 °F 50 °F to 400 °F 400 °F to 1832 °F |
- ± (2.0 % rdg + 4 °C) ± (1.0 % rdg + 3 °C) ± (3.0 % rdg + 2 °C) ± (2.0 % rdg + 8 °F) ± (1.0 % rdg + 6 °F) ± (3.0 % rdg + 4 °F) |
Resolution | 0.1°C, 0.1°F | - |
Overload Protection | 1000V DC or 750V AC RMS 1000V 600V 300V |
- |
Frequency | 4k, 40k, 400k, 1M | ±0.1% rdg + 3 dgts |
Resolution | 1Hz | - |
Sensitivity | 10Hz to 1MHz: 2.5V rms | - |
Minimum Pulse Width | <35ns | - |
Duty Cycle Limits | >30 % and <70 % | - |
Overload Protection | 1000V DC or 750V AC RMS | - |
Continuity | - | |
Audible Indication | Less than 25Ω | - |
Response Time | 100ms | - |
Overload Protection | 1000V DC or 750V AC RMS | - |
Diode Test | - | |
Test Current | 1.2mA (approx) | ± (1.5% + 3 dgts) |
Resolution | 1mV | - |
Open Circuit Voltage | 3.0 DC typical | - |
Overload Protection | 1000V DC or 750V AC RMS | - |
Non-Contact Voltage Indicator | If voltage between 70V and 600V is detected beeper chirps and bright red LED switches on |
- |
Description
Beha-Amprobe 35XP-A Digital Multimeter
The Beha-Amprobe 35XP-A Multimeter is ideally suited to general electricians, plant maintenance and HVAC engineers.
It can measure up to 750V AC, 1000V DC and current to 2A. It comes complete with a thermocouple and K type probe allowing temperature measurement to 1000°C.
It will also measure resistance to 40MΩ and capacitance to 400μF. The included Magne-grip holster also allows you to temporarily fix the meter to a metallic surface to aid hands free operation.
Beha-Amprobe 35XP-A Comes Supplied With:
- TL245A Test Leads
- TP255A K-Type Thermocouple
- XR-TA Temperature Adapter
- 2A/1000V Fuse
- 9V Battery (installed in meter)
- Magne-Grip Holster + Magnetic Hanging Strap
- User Manual
Key Features:
• Voltage, current and resistance measurement
• Capacitance and frequency measurement
• Diode and acoustic continuity test
• Temperature measurement
• Measurement of ionisation currents in heating systems
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• Shock-proof and impact-resistant thanks to
standard protective holster
• Auto power-off
• Non-contact voltage detection (NCV)
Features & Specification
Key Features | Measures resistance, Measures frequency, Measures capacitance, AC/DC voltage, AC/DC current, Temperature function, Auto and Manual Range, Data Hold Min/Max | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Amprobe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|