Beha-Amprobe 30XR-A Multimeter

£95.94
Amprobe 30XR-A Auto-ranging Multimeter
FEATURE 30XR-A
DC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance -
Frequency -
Temperature -
Duty cycle
Logic test
Inductance
dBm

 

Amprobe 30XR-A Auto-ranging Multimeter
Specifications
DC Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage accuracy: all ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution: 100 µV
DC Voltage input impedance: 10 MO
AC Voltage (45 Hz to 500 Hz) ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy: all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution: 100 µV
AC Voltage (45 Hz to 500 Hz) input impedance: 10 MO
DC Current ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy: 200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current accuracy: 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution: 0.1 µA
DC Current voltage burden (max): 200 µA range: 1 mV/µA
DC Current voltage burden (max): 2 mA range: 100 mV/1mA
DC Current voltage burden (max): 20 mA range: 13 mV/1 mA
DC Current voltage burden (max): 200 mA range: 4.6 mV/1 mA
DC Current voltage burden (max): 10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) accuracy: 10A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution: 0.1 µA
AC Current voltage burden: See DC Current
Non-contact voltage detector (NCV) AC volts: 70 to 600 V ac
Non-contact voltage detector (NCV): Red LED and Audible Indicator

 

Description

Beha-Amprobe 30XR-A Auto-ranging Multimeter

 

For non-contact voltage testing, Amprobe 30XR-A Digital Multimeter offers Voltect™ non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions.

 

Amprobe 30XR-A Come Supplied With:

  • Test leads (TL36A)
  • 9 V battery (installed)
  • Magne-Grip™ Holster with magnetic hanging strap
  • Spare Fuse
  • User Manual


Key Features:

  • Non-contact voltage detector
  • Separate door for easy battery and fuse access
  • Manual ranging; display: 3-1/2 digit LCD, 1999 counts
  • Display update rate: 2.5/sec, nominal
  • Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Low battery indication
  • Overrange indication
  • Min/max and data Hold
 
 


Features & Specification

More Information
Key Features Tests up to 500V, Measures resistance, Measures frequency, AC/DC voltage, AC/DC current, Backlit Display, Auto and Manual Range, Data Hold Min/Max
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Amprobe
Short Description
Amprobe 30XR-A Auto-ranging Multimeter
FEATURE 30XR-A
DC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance -
Frequency -
Temperature -
Duty cycle
Logic test
Inductance
dBm

 

Amprobe 30XR-A Auto-ranging Multimeter
Specifications
DC Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage accuracy: all ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution: 100 µV
DC Voltage input impedance: 10 MO
AC Voltage (45 Hz to 500 Hz) ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy: all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution: 100 µV
AC Voltage (45 Hz to 500 Hz) input impedance: 10 MO
DC Current ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy: 200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current accuracy: 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current resolution: 0.1 µA
DC Current voltage burden (max): 200 µA range: 1 mV/µA
DC Current voltage burden (max): 2 mA range: 100 mV/1mA
DC Current voltage burden (max): 20 mA range: 13 mV/1 mA
DC Current voltage burden (max): 200 mA range: 4.6 mV/1 mA
DC Current voltage burden (max): 10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) accuracy: 10A range: ± (2.5 % rdg + 4 dgts)
AC Current resolution: 0.1 µA
AC Current voltage burden: See DC Current
Non-contact voltage detector (NCV) AC volts: 70 to 600 V ac
Non-contact voltage detector (NCV): Red LED and Audible Indicator

 

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA