CRT-400 Specifications (Specifications subject to change without notice.) | |||
Physical | |||
Dimensions | H 305mm (12") x W 178mm (7") x D 76mm (3") | ||
Weight | 1.5Kg (3.4lb) | ||
Keypad | Rubber keys with polyurethane coating | ||
Display | |||
Type | LCD - STN Reflective | ||
Viewing Area | 2.619" x 1.309" | ||
Resolution | Graphics LCD 128 x 64 | ||
Viewing Angle | 40° | ||
Backlight | White LED | ||
Memory | |||
Type | USB | ||
Storage Capability | 1 MB per 71 strings with 256 cells | ||
Data Retention | 10 years | ||
Communication | |||
Infrared | PC Interface for data transfer Physical IrDA compliant for printer interface |
||
Battery | |||
Type | 4 cell - 8800 mAh lithium ion | ||
Voltage | 4.2V | ||
Charge Time | 8 hrs | ||
AC Adapter | |||
Input Voltage | 90 - 264 VAC | ||
Output Voltage | 5 VDC | ||
Output Current | 4.0 Amps | ||
Frequency | 47 - 63 HZ | ||
Miscellaneous | |||
Operating Temperature | 0˚C - 40˚C (32˚F - 104˚F) | ||
Storage Temperature | -29˚C - 60˚C (-20˚F - 140˚F); For extended periods <25˚C (<77˚F) | ||
Humidity Range | 0% to 80% RH (noncondensing) at 0˚C - 31˚C; 0% to 50% RH (non-condensing) at 32˚C - 40˚C | ||
Insulation Category II | |||
Pollution Degree 2 | |||
Altitude | 0 to 2000 meters above sea level |
Description
Alber CTL-400 Cellcorder Battery Tester
Accurate data in a fraction of normal test time
The intelligent, lightweight CellCorder cell resistance tester displays and records cell float voltage, internal cell resistance, and inter-cell connection resistance. Using a compatible hydrometer such as our CTL-200 Hydrostik Digital Data logging Hydrometer / Thermometer, you may automatically transfer data, such as specific gravity and temperature, using the onboard infrared port.
Use the CellCorder on single-cell or multi-cell modules. Data is stored using a memory card that allows virtually an unlimited amount of data storage. The memory card, IR port, or internal modem transfers readings to a PC for analysis and advanced report generation via the supplied software.
The high contrast, 128 x 64 pixel, backlit graphical display shows menus and test results. A fully charged CellCorder can test for up to seven hours, and isolated operation helps ensure safety and makes the CellCorder easy to move around. Recharge power is supplied by a wall plug adapter.
Low cost The CellCorder replaces three instruments that individually cost as much as or more than this one instrument. Significant savings result from taking more readings in less time and analysing data more rapidly.
Multi-cell capability The CellCorder provides readings on either single cells or Multi-cell modules.
Reliable readings The CellCorder displays superior performance even in high-noise environments - without the need to disconnect the battery from service. The instrument uses up to a 60 amp DC load (on 2V cells) to calculate internal cell resistance and inter-cell resistance. Circuitry rejects the 50Hz/60Hz ripple often troublesome to AC-based impedance and conductance meters.
System Measurements:
- Float Voltage Readings
- NiCads to Multicell Modules (16V)
- Internal Cell Resistance Measurement
- Internal Resistance Connection
- Intertier Resistance Connection
Battery Analysis Software:
- Full-featured software easily identifies problem cells.
- Built-in report generator creates tabular or graphical reports.
- Stores all historical data for trending and analysis as well as for warranty purposes and audits.
- Import temperature and specific gravity readings into the BAS software for trending and analysis.
System Advantages and Features:
- Reliable readings even in the noisiest environments.
- USB Flash drive for easy data transfer and storage.
- Multiple test lead options and connections for all battery types.
- Optional battery harness assembly increases efficiency and safety..
The CTL-400 Comes Supplied With:
- Memory Stick
- USB port memory card reader
- *Resistance test leads 1100-221 or 1100-231 (Please see purchasing options)
- Voltage test leads 1100-222
- Carrying case
- AC charger
- Data trending and analysis software
*Included lead Sets
Included in the purchase price are either 1100-221 Standard Leads or 1100-231 Combined Leads. The 1100-221 Standard Leads will satisfy most requirements as the 3rd clamp is needed for those wishing to test the resistance of the intercell connection.
The voltage test leads 1100-222 come supplied additionally as standard.
Float Voltage Readings
Cellcorder Advantages:
Low Cost - The Alber Cellcorder replaces three instruments that individually cost more than this one. Significant savings also result from taking more readings in less time and analyzing data faster.
Multicell Capability - The Cellcorder reads either single cells or multicell modules.
Reliable Readings - The Cellcorder performs even in high-noise environments - without the need to disconnect the battery from service. Up to a 60 amp DC load (on 2V cells) is used to calculate internal cell resistance and intercell resistance. Circuitry rejects the 50Hz/60Hz ripple often troublesome to AC-based impedance and conductance meters.
Spares and Accessories:
- 2027-014: CRT BAS Software
- 2025-124: Printer with IRDA interface
- 2023-036: Bluetooth® Earpiece
- 2030-005: USB Flash Drive
- Various: Spike Probe Options
Features & Specification
Key Features | Cell Resistance Measurement, Data Storage, Float Voltage Testing, LCD Display, Printer Output, Windows Compatible Software, Battery Voltage Test | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Alber | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA