Dilog DL9118 18th Edition Multifunction Tester

£1,545.60
Di-Log DL91xx Series Technical Specification
Voltage
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0V to 440V 0V to 480V
Measuring Range 0V to 440V 0V to 480V
Resolution 1V 1V
Voltage Accuracy +/- 5% +/- 2digits +/- 5% +/- 2digits
Frequency Range 45Hz – 65Hz 45Hz – 65Hz
Frequency Accuracy +/- 1Hz +/- 1Hz
         
Continuity
  DL9110 DL9118 DL9120 DL9130EV
Display Range (200mA) 0.01Ω to 200Ω 0.01Ω to 2000Ω
Measuring Range (200mA) 0.10Ω to 200Ω 0.10Ω to 2000Ω
Accuracy +/- 2% +/- 5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 200Ω
0.01Ω to 19.99Ω
20.0Ω to 199.9Ω
200Ω to 2000Ω
Test Voltage >4Vdc <25Vdc Open Circuit
Test Current >200mA
Display Range (15mA)       0.01Ω to 200Ω
Accuracy       +/- 2% +/- 5 digits
Resolution       0.01Ω to 19.99Ω
20.0Ω to 199.9Ω
        >4Vdc <25Vdc
Open Circuit
        >15mA
Compliance IEC61557-1, IEC61557-4 and IEC61557-10
         
Insulation
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0.01MΩ to 200MΩ
Display Range 0.05MΩ to 200MΩ
Accuracy +/-5% +/-5 digits
Resolution 0.01MΩ to 1.99MΩ
2.0MΩ to 19.9MΩ
20MΩ to 200MΩ
Alarm Warning <1MΩ Audible <1MΩ Screen & Audible
Test Voltage 250/500 250/500/1000V
Test Voltage Specification -0% +20% (open circuit)
Test Current 1mA into UN (1000Ω/V)
Compliance IEC61557-1, IEC61557-2 and IEC61557-10
                             
No Trip Loop Impedance
  DL9110 DL9118 DL9120 DL9130EV
Supply voltage 195-253V, 45Hz – 65Hz
Display Range 0.01Ω to 2000Ω
Measuring Range 1.00 to 1999Ω (non-trip)
Accuracy +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Test Current <15mA RMS
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
         
High Current Loop Impedance
  DL9110 DL9118 DL9120 DL9130EV
Supply voltage 195-253V, 45Hz – 65Hz
Display Range 0.01Ω to 2000Ω
Measuring Range 0.10Ω to 1999Ω (high current)
Accuracy +/-5% +/-5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Test Current 3A RMS
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
         
Loop Test PFC Measurement
  DL9110 DL9118 DL9120 DL9130EV
Display Range 1A to 26kA 0.1A to 26.0kA
Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits
Resolution 1A to 999A
1kA to 26kA
0.1A to 999.9A
1.0kA to 26.0kA
         
High Current Line Impedance
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0.01Ω to 2000Ω 0.01Ω to 2000Ω
Measuring Range 0.10Ω to 2000Ω 0.10Ω to 2000Ω
Accuracy +/-5% +/-5 digits +/-5% +/-5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Supply Voltages 195V – 253V 195V – 253V
328V – 440V
195V – 253V
328V – 480V
Test Current 3A RMS Peak
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
Line Test PSC Measurement
  DL9110 DL9118 DL9120 DL9130EV
Range 1A to 26kA 0.1A to 26.0kA
Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits
Resolution 1A to 999A
1kA to 26kA
0.1A to 999.9A
1.0kA to 26.0kA
             
RCD Trip Time Test
  DL9110 DL9118 DL9120 DL9130EV
Supply Voltages 195-253V, 45Hz – 65Hz
Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
Variable Mode
Variable RCD Test   1mA – 500mA
Test Current Accuracy -0% +10% at I∆n and 5I∆n
-0% +10% at ½ I∆n
Trip Time Ranges 0 to 2000ms ½ I∆n 0ms - 300ms I∆n general 0ms - 500ms I∆n selective
0 to 40ms 5 I∆n
Trip Time Accuracy +/- 5% +/- 2 digits
Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
             
RDC-DD Trip Time Test
  DL9110 DL9118 DL9120 DL9130EV
Supply Voltages   195-253V, 45Hz –
65Hz
Nominal Test Current   6mA
Test Current Accuracy   -0% +10%
Trip Time Ranges   0 to 10000 I∆n
Trip Time Accuracy   +/- 5% +/- 2 digits
Ramp Test Current Range   2mA – 6mA
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
             
RCD (Ramp) Trip Current Test
Range 0.5 I∆n to 1.1 I∆n
Range (6mA DC)   0.1mA to 6mA
(over 30 seconds)
Accuracy +/-5% of the expected current
Step Size 0.1*∆n
Step duration 300ms
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
Additional Data
  DL9110 DL9118 DL9120 DL9130EV DL9130EVKIT
Weight 1360g  
Dimensions Width 236mm
Depth 130mm Height 91mm
 
DL91xx Boxed 3045g 3075g 3045g 3075g 5050g
DL91xx Boxed Dimensions Width 380mm Depth 195mm
Height 250mm
Width 400mm Depth 280mm
Height 300mm
EAN Barcode 5060082543463 5060082543449 5060082544156 5060082544163 5060082544361
                 
Box Contents
DL9110 DL9118 DL9120 DL9130EV
Multifunction Tester Multifunction Tester
Padded neck strap Padded neck strap
Professional toolbox style carry case Professional toolbox style carry case
Mains lead Mains lead
1.2M black test lead 1.2M Blue test lead
1.2M red test lead 1.2M red test lead
1.2M green test lead 1.2M green test lead
Black crocodile clip Blue crocodile clip
Red crocodile clip Red crocodile clip
Green crocodile clip Green crocodile clip
MN1500 (AA) 1.5v Batteries x 6 MN1500 (AA) 1.5v Batteries x 6
Operating Instruction Manual Operating Instruction Manual
Calibration certificate Calibration certificate
(Optional) Remote Test Probe (Optional) Remote Test Probe
                 
DL9100 Series Spares and Accessories
DL9110 DL9118 DL9120 DL9130EV
LS3W9073 – Red/Black/Green 3 wire lead set c/w croc
clips and probes
LS3W9100 – Red/Blue/Green 3 wire lead set c/w croc
clips and probes
ML9073 – Red/Black/Green 13A to 4mm mains lead ML9100 – Red/Blue/Green 13A to 4mm mains lead
RP9100 – Remote Test Probe (suitable for DL9100 Series testers)
CCDL9100 – Toolbox Style Carry Case
AF27B – 1.6A 1000V HRC FF Fuse DL9100fuse - 500mA 1000V HRC FF Fuse
   
   
       
FREE GIFTS | UKAS Cal Cert

Description

This instrument comes complete with your choice of free gift from the drop-down menu above. Choose from a calibration voucher for next 
year or a 50m R2 wander lead. How about any one of the IET Guidance Notes, or a quality two-pole tester? 
Whatever you choose you can be sure you're getting a fantastic deal at Instrument Sales & Service.

DiLog DL9118 17th Edition Multifunction Tester

Test continuity, voltage, insulation, high and low current loop impedance, phase rotation, PFC loop tests, RCD trip time and current tests and loop impedance all in one unit.

The ALL NEW Di-Log DL9118 multifunction tester has been designed to fully comply with the testing requirements of the 17th Edition. It also incorporates many of the features that we have come to expect with modern MFTs. It is designed to be worn around the neck with a comfortable harness, for easy function selecting and testing.

The All NEW RCD-LOC XLT feature allows loop testing without tripping any type of RCD or RCBO with very high accuracy. The DL9118 is also packed full of features, such as a Remote Test Probe, Auto Start Loop & Continuity, colour changing LCD display indicating error, and comes complete with a toolbox style carry case.  All in all, the DL9118 offers incredible value for a feature packed MFT meeting all the safety and performance requirements of BS EN 61557.

*Important Calibration Information:

This instrument comes complete with the manufacturer's dated calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.

Di-Log DL9118 Comes Supplied With:

  • Rugged Carry Case
  • Manufacturers Certificate
  • Remote Probe
  • Set of Shielded Test leads with Crocodile Clips
  • Shielded AC Power Cord

Key Features:

  • Loop Impedance – Unique auto start RCD-LOC XLT loop test principle will not trip any RCD
  • Tests the new type A RCD's
  • Prospective short circuit current – with auto start and direct readout of PSCC
  • High Current Loop Test – auto start loop test with high current Ze measurement
  • Phase Rotation Test – will indicate the correct phase sequence
  • Continuity test – with auto start & null facility to zero out lead resistance
  • RCD testing – Trip time, trip current, auto test and ramp current
  • RCD auto test – test RCDs in auto mode and simply recall the test results once finished
  • Insulation measurement – with 250, 500 & 1000V test voltages
  • Integrated socket polarity test
  • Fully protected against damage when accidentally connected across phases
 
 
 
 

About Di-Log

Di-Log Test Equipment offers a comprehensive range of test equipment from a voltage indicator to 18th Edition and Thermal Imaging to portable  appliance testing kits. All Di-Log instruments are designed and manufactured to the highest quality specification and you can be assured that all manufacturing processes adhere to internationally recognised standards.  Di-Log instruments are accurate, safe and rugged – you won’t find a better balance between cost and fitness for purpose.
 

 

Features & Specification

More Information
Key Features Manufacturer Certificate Included, Phase Rotation Service, Earth Testing, Auto RCD, Backlit LCD Display, Non Trip Loop Testing, Memory Function
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Dilog
Short Description
Di-Log DL91xx Series Technical Specification
Voltage
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0V to 440V 0V to 480V
Measuring Range 0V to 440V 0V to 480V
Resolution 1V 1V
Voltage Accuracy +/- 5% +/- 2digits +/- 5% +/- 2digits
Frequency Range 45Hz – 65Hz 45Hz – 65Hz
Frequency Accuracy +/- 1Hz +/- 1Hz
         
Continuity
  DL9110 DL9118 DL9120 DL9130EV
Display Range (200mA) 0.01Ω to 200Ω 0.01Ω to 2000Ω
Measuring Range (200mA) 0.10Ω to 200Ω 0.10Ω to 2000Ω
Accuracy +/- 2% +/- 5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 200Ω
0.01Ω to 19.99Ω
20.0Ω to 199.9Ω
200Ω to 2000Ω
Test Voltage >4Vdc <25Vdc Open Circuit
Test Current >200mA
Display Range (15mA)       0.01Ω to 200Ω
Accuracy       +/- 2% +/- 5 digits
Resolution       0.01Ω to 19.99Ω
20.0Ω to 199.9Ω
        >4Vdc <25Vdc
Open Circuit
        >15mA
Compliance IEC61557-1, IEC61557-4 and IEC61557-10
         
Insulation
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0.01MΩ to 200MΩ
Display Range 0.05MΩ to 200MΩ
Accuracy +/-5% +/-5 digits
Resolution 0.01MΩ to 1.99MΩ
2.0MΩ to 19.9MΩ
20MΩ to 200MΩ
Alarm Warning <1MΩ Audible <1MΩ Screen & Audible
Test Voltage 250/500 250/500/1000V
Test Voltage Specification -0% +20% (open circuit)
Test Current 1mA into UN (1000Ω/V)
Compliance IEC61557-1, IEC61557-2 and IEC61557-10
                             
No Trip Loop Impedance
  DL9110 DL9118 DL9120 DL9130EV
Supply voltage 195-253V, 45Hz – 65Hz
Display Range 0.01Ω to 2000Ω
Measuring Range 1.00 to 1999Ω (non-trip)
Accuracy +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Test Current <15mA RMS
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
         
High Current Loop Impedance
  DL9110 DL9118 DL9120 DL9130EV
Supply voltage 195-253V, 45Hz – 65Hz
Display Range 0.01Ω to 2000Ω
Measuring Range 0.10Ω to 1999Ω (high current)
Accuracy +/-5% +/-5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Test Current 3A RMS
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
         
Loop Test PFC Measurement
  DL9110 DL9118 DL9120 DL9130EV
Display Range 1A to 26kA 0.1A to 26.0kA
Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits
Resolution 1A to 999A
1kA to 26kA
0.1A to 999.9A
1.0kA to 26.0kA
         
High Current Line Impedance
  DL9110 DL9118 DL9120 DL9130EV
Display Range 0.01Ω to 2000Ω 0.01Ω to 2000Ω
Measuring Range 0.10Ω to 2000Ω 0.10Ω to 2000Ω
Accuracy +/-5% +/-5 digits +/-5% +/-5 digits
Resolution 0.01Ω to 1.99Ω
2.0Ω to 19.9Ω
20Ω to 2000Ω
0.01Ω to 9.99Ω
10.0Ω to 99.9Ω
100Ω to 2000Ω
Supply Voltages 195V – 253V 195V – 253V
328V – 440V
195V – 253V
328V – 480V
Test Current 3A RMS Peak
Compliance IEC61557-1, IEC61557-3 and IEC61557-10
Line Test PSC Measurement
  DL9110 DL9118 DL9120 DL9130EV
Range 1A to 26kA 0.1A to 26.0kA
Accuracy +/-5%  +/-5 digits +/-5%  +/-5 digits
Resolution 1A to 999A
1kA to 26kA
0.1A to 999.9A
1.0kA to 26.0kA
             
RCD Trip Time Test
  DL9110 DL9118 DL9120 DL9130EV
Supply Voltages 195-253V, 45Hz – 65Hz
Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
Variable Mode
Variable RCD Test   1mA – 500mA
Test Current Accuracy -0% +10% at I∆n and 5I∆n
-0% +10% at ½ I∆n
Trip Time Ranges 0 to 2000ms ½ I∆n 0ms - 300ms I∆n general 0ms - 500ms I∆n selective
0 to 40ms 5 I∆n
Trip Time Accuracy +/- 5% +/- 2 digits
Nominal Test Current 10mA/30mA/100mA ( ½ , 1, 5 I∆n)
300mA/500mA ( ½, 1 I∆n)
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
             
RDC-DD Trip Time Test
  DL9110 DL9118 DL9120 DL9130EV
Supply Voltages   195-253V, 45Hz –
65Hz
Nominal Test Current   6mA
Test Current Accuracy   -0% +10%
Trip Time Ranges   0 to 10000 I∆n
Trip Time Accuracy   +/- 5% +/- 2 digits
Ramp Test Current Range   2mA – 6mA
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
             
RCD (Ramp) Trip Current Test
Range 0.5 I∆n to 1.1 I∆n
Range (6mA DC)   0.1mA to 6mA
(over 30 seconds)
Accuracy +/-5% of the expected current
Step Size 0.1*∆n
Step duration 300ms
Compliance IEC61557-1, IEC61557-6 and IEC61557-10
Additional Data
  DL9110 DL9118 DL9120 DL9130EV DL9130EVKIT
Weight 1360g  
Dimensions Width 236mm
Depth 130mm Height 91mm
 
DL91xx Boxed 3045g 3075g 3045g 3075g 5050g
DL91xx Boxed Dimensions Width 380mm Depth 195mm
Height 250mm
Width 400mm Depth 280mm
Height 300mm
EAN Barcode 5060082543463 5060082543449 5060082544156 5060082544163 5060082544361
                 
Box Contents
DL9110 DL9118 DL9120 DL9130EV
Multifunction Tester Multifunction Tester
Padded neck strap Padded neck strap
Professional toolbox style carry case Professional toolbox style carry case
Mains lead Mains lead
1.2M black test lead 1.2M Blue test lead
1.2M red test lead 1.2M red test lead
1.2M green test lead 1.2M green test lead
Black crocodile clip Blue crocodile clip
Red crocodile clip Red crocodile clip
Green crocodile clip Green crocodile clip
MN1500 (AA) 1.5v Batteries x 6 MN1500 (AA) 1.5v Batteries x 6
Operating Instruction Manual Operating Instruction Manual
Calibration certificate Calibration certificate
(Optional) Remote Test Probe (Optional) Remote Test Probe
                 
DL9100 Series Spares and Accessories
DL9110 DL9118 DL9120 DL9130EV
LS3W9073 – Red/Black/Green 3 wire lead set c/w croc
clips and probes
LS3W9100 – Red/Blue/Green 3 wire lead set c/w croc
clips and probes
ML9073 – Red/Black/Green 13A to 4mm mains lead ML9100 – Red/Blue/Green 13A to 4mm mains lead
RP9100 – Remote Test Probe (suitable for DL9100 Series testers)
CCDL9100 – Toolbox Style Carry Case
AF27B – 1.6A 1000V HRC FF Fuse DL9100fuse - 500mA 1000V HRC FF Fuse
   
   
       

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA