Kewtech KT63 PLUS Multifunction Tester Specification
Loop Impedance
Range Measurement Range Accuracy System Voltage Range
High Current - Hi res, 2Wire 0.000Ω to 9.999Ω +/-(3%+30mΩ) 100-440V AC
Loop/PFC-PSC High Current 2 W 7A nom @ 230V 0.00 to 500.0Ω +/-(5%+3digits) 100-440V AC
Loop No Trip 3 W 13mA nom @ 230V 0.00 to 500.0Ω +/-(5%+3digits) 195V - 253V AC

System Voltage 50-60Hz

RCD (AC/A & ACS/AS)
System Voltage Range Sytem frequency Nominal currrents (mA) Touch / fault votage Trip Time accuracy
195 - 253V AC 50-60 Hz 30, 100, 300, 500 50V +/-(1%+1ms)
Test Current 1/2 1 x5 (30mA only) R Ramp
Accuracy +0-10% +10%-0% +10%-0% +/-5% of rated I∆N
Ramp Characteristics 20% to 110% of rated I∆N in 10% steps (300ms dwell time)

CONTINUITY
Measurment Range Accuracy Open Circuit voltage Short circuit current at 2Ω Max Lead resistance null
0.00Ω to 19.99kΩ +/-(3%+32 digits) >4V - <10V >200mA

INSULATION
Test Voltage Measurment Range Accuracy Short Circuit current into 2kΩ
250V 0.001 to 200.0MΩ Ω +/-(3%+2digits + 10%/GΩ) <2mA
200V 0.001 to 500.0MΩ +/-(3%+2digits + 5%/GΩ) <2mA
1000V 0.001 to 1000MΩ +/-(3%+2digits + 2.5%/GΩ) <2mA
Output Voltage Load Accuracy Output current
250V 250Ω -0%+20% 1mA
500V 500Ω -0%+20% 1mA
1000V 1000Ω -0%+20% 1mA

GENERAL SPECIFICATIONS
Dimensions Accuracy
Weight (With Batteries) 965g
Battery Type 6 x AA / LR6 Alkaline
Category Rating 300V CAT IV 600V CAT III
Ingress Protection Rating IP54
Operating / Storage Temperature 0°C to 40°C / -10°C to 60°C
Operating Humidity / Altitude 80% @ 31°C to 50% @ 40 °C / 0 to 2000m
FREE Gift

Description



This instrument comes complete with your choice of free gift from the drop-down menu above. Choose from a calibration voucher for next 
year or a 50m R2 wander lead. How about any one of the IET Guidance Notes, or a quality two-pole tester? 
Whatever you choose you can be sure you're getting a fantastic deal at Instrument Sales & Service.

Kewtech KT63 PLUS 6 in 1 Multifunction Tester

The 6 in 1, easy to use, 18th Edition Multifunction Tester with a large colour dot matrix display making function selection and the reading of multi-test results as easy as it comes.

*Calibration Options:

This instrument comes complete with the manufacturers dated calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.


The KT63 PLUS Comes Supplied With:

  • Test lead with remote test button
  • ACC063 G7 Test lead set
  • KAMP12 mains lead
  • Batteries
  • Instruction Manual


Key Features:

  • Anti-Trip Technology for full no trip LOOP testing on all RCD types
  • Test button in probe as well as lockdown test button for ‘hands free’ testing
  • Easy PFC & PSC measurement without the need to alter test probes
  • 250, 500 & 1000V insulation tests with auto discharge
  • Memory for test lead resistance compensation
  • Backlit display
  • RCD tests AC / A & ACS / AS
  • Auto-test memory for RCD testing with all results shown on one screen, so no scrolling
  • RCD ratings 10, 30, 100, 300, 500, 1000mA
  • Phase Rotation
  • Three ways to start a test - single press of the test button, handsfree use of the test button (continuous testing) or by the test button in the additional test probe
  • Special DNO polarity test
  • IP54
  • End of line calibration certificate included
  • Complies with BS7671


Key Benefits:

  • Easy to use – single rotary dial with four secondary function keys
  • New anti-trip technology loop test - for full no trip loop testing with RCDs of 30mA and above for all types (electronic & electro-mechanical) with very low susceptibility of RCD uplift and noise interference
  • No Bangs – continuous live monitoring means no blown fuses or PCBs
  • UK specific RCD test, all six results are presented on one screen - no scrolling
  • Three ways to start a test - single press of the test button, handsfree use of the test button (continuous testing) or by the test button in the test probe


Spares & Accessories (Not Included):

  • FC2000 check box
  • Lightmate kit – for fast connection to light fittings
  • Pat Adaptor1 – converts your KT63PLUS into a PAT Tester
  • Jumpld1 - Link out leads for cont / ins testing

Which Kewtech Multifunction Tester is Right For Me?

ISSWWW and Kewtech

One of our longest standing manufacturer partnerships and a brand that sells well day in day out for solid dependability and innovation at the price point.
Kewtech manufacture innovative, accurate and reliable test equipment that enables UK electrical contractors to undertake their testing obligations quickly and efficiently. 
A product with the “Kewtech” brand has been specifically designed for the UK market by a team with many years of industry experience. We pride ourselves on developing and manufacturing products that have real benefit to the industry.

Kewtech have consistently introduced industry firsts, like our Lightmate testing adaptors, the Pat Adaptor, the MFT with PAT testing plus download and our award winning RB1 Replacement Lamp. Our 18th Edition multifunction testers lead the way in ease of use, loop accuracy and repeatability of reading.

Features & Specification

More Information
Key Features 30mA RCD Autotest, >1000V Insulation Testing, Displays PFC/PSC/Loop simultaneously, Easy to use rotary dial, Insulation test >1000V, Phase rotation, RCD ratings >1000mA, RCD tests AC/A & ACS/AS
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Kewtech
Short Description
Kewtech KT63 PLUS Multifunction Tester Specification
Loop Impedance
Range Measurement Range Accuracy System Voltage Range
High Current - Hi res, 2Wire 0.000Ω to 9.999Ω +/-(3%+30mΩ) 100-440V AC
Loop/PFC-PSC High Current 2 W 7A nom @ 230V 0.00 to 500.0Ω +/-(5%+3digits) 100-440V AC
Loop No Trip 3 W 13mA nom @ 230V 0.00 to 500.0Ω +/-(5%+3digits) 195V - 253V AC

System Voltage 50-60Hz

RCD (AC/A & ACS/AS)
System Voltage Range Sytem frequency Nominal currrents (mA) Touch / fault votage Trip Time accuracy
195 - 253V AC 50-60 Hz 30, 100, 300, 500 50V +/-(1%+1ms)
Test Current 1/2 1 x5 (30mA only) R Ramp
Accuracy +0-10% +10%-0% +10%-0% +/-5% of rated I∆N
Ramp Characteristics 20% to 110% of rated I∆N in 10% steps (300ms dwell time)

CONTINUITY
Measurment Range Accuracy Open Circuit voltage Short circuit current at 2Ω Max Lead resistance null
0.00Ω to 19.99kΩ +/-(3%+32 digits) >4V - <10V >200mA

INSULATION
Test Voltage Measurment Range Accuracy Short Circuit current into 2kΩ
250V 0.001 to 200.0MΩ Ω +/-(3%+2digits + 10%/GΩ) <2mA
200V 0.001 to 500.0MΩ +/-(3%+2digits + 5%/GΩ) <2mA
1000V 0.001 to 1000MΩ +/-(3%+2digits + 2.5%/GΩ) <2mA
Output Voltage Load Accuracy Output current
250V 250Ω -0%+20% 1mA
500V 500Ω -0%+20% 1mA
1000V 1000Ω -0%+20% 1mA

GENERAL SPECIFICATIONS
Dimensions Accuracy
Weight (With Batteries) 965g
Battery Type 6 x AA / LR6 Alkaline
Category Rating 300V CAT IV 600V CAT III
Ingress Protection Rating IP54
Operating / Storage Temperature 0°C to 40°C / -10°C to 60°C
Operating Humidity / Altitude 80% @ 31°C to 50% @ 40 °C / 0 to 2000m

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA