Like most organisations we use cookies on our site, these allow us to improve your experience on our site, provides us with measurement and analytical data, and allows us to make use of the latest digital marketing capabilities - if you want to know more about cookies and how you can control them see our cookie policy here, if you are happy for us to use cookies then please click the button opposite.

Fluke MDA-510 Motor Drive Analyzer

Simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results.

Next Day Delivery (subject to availability)

£5,000.00 excluding VAT £6,000.00 including VAT @ 20% Regular Price: £6,080.40
  • Colour Display
  • 4 channel, 500MHz
  • 1100 counts Full Scale Reading
  • ax peak, min peak, or pk-to-pk
  • 1000 V AC/DC
  • FreeDelivery
  • 30DayMoneyBack
  • Description
  • Features & Specification
  • Resources
  • Delivery

Fluke MDA-510 Motor Drive Analyzer

This motor-drive analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying the troubleshooting process. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, this tool has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence. It is the ideal portable motor-drive analysis test tool, and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.


The MDA-510 Comes Supplied With:

  • Motor Drive Analyzer
  • 1x BP 291 li-ion battery pack
  • 1x BC190 charger/power adapter
  • 3x VPS 100:1 high voltage probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage probe
  • 1x i400s ac current clamp
  • 1x C1740 carrying case
  • 1x 2 GB USB drive with manuals and FlukeView™ 2 software

The MDA-510 Comes Supplied With:

Key Features:

  • Measures inverter output voltage, DC bus voltage and ripple voltage, harmonics, unbalance
  • Three powerful test tools in one: Motor-drive analyzer, waveform analyzer and recording data logger all in one
  • Four input channels for voltage and current signals
  • Measure key motor-drive parameters including
    • Voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance and voltage modulation
    • The MDA-550 also performs perform extended harmonics measurements to identify the effects of low and high order harmonics on your electrical power system.
  • Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure.
  • Create reports quickly and easily that are perfect for docu¬menting troubleshooting and collaborative work with others.
  • Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems.
  • Includes USB A, and USB mini B connectivity

Drive Input 

Measure input voltage and current to quickly see whether values are within acceptable limits by comparing the drive’s nominal rated voltage to the actual supplied voltage. Then, check the input current to determine if the current is within the maximum rating and the conductors are suitably sized.

Voltage and Current Unbalance

Check the voltage unbalance at the input terminals so you can ensure the phase unbalance is not too high (>6 to 8%), and that the phase rotation is correct. You can also check the current unbalance, as excessive unbalance may indicate a drive rectifier problem.

DC Bus

In a motor-drive the conversion of AC to DC inside the drive is critical, having the correct voltage and adequate smoothing with low ripple is required for the best drive performance. High ripple voltage may be an indicator of failed capacitors or incorrect sizing of the connected motor. The record function can be used to check DC bus performance dynamically in the operating mode while a load is applied.

Drive Output

Check the output of the drive focusing both on voltage to frequency ratio (V/F), and voltage modulation. When high V/F ratio measurements are experienced, the motor may overheat. With low V/F ratios, the connected motor may not be able to provide the required torque at the load to sufficiently run the intended process.

Voltage Modulation

Measurements of the Pulse Width Modulated signal are used to check for high voltage peaks which can damage motor winding insulation. The rise time or steepness of impulses is indicated by the dV/dt reading (rate of voltage change over time), this should be compared to the motor’s specified insulation. The measurements can also be used to measure switching frequency to identify whether there is a potential issue with electronic switching, or with grounding, where the signal floats up and down.

Motor Input

Ensuring that voltage is being supplied at the motor input terminals is key, and the selection of cabling from drive to the motor is critical. Incorrect cabling selection can result in both drive and motor damage due to excessive reflected voltage peaks. Checking that the current present at the terminals is within the motor rating is important as over current condition could cause the motor to run hot, decreasing the life of the stator insulation which can result in the early failure of the motor.

Step-by-Step Guided Measurements Ensure You Have the Data You Need, When You Need It

Designed to help you quickly and easily test and troubleshoot typical problems on three-phase and single-phase inverter type motor-drive systems. The on-screen information, and step-by-step setup guidance make it easy to con- figure the analyzer and get the drive measurements you need to make better maintenance decisions, fast. From power input to the installed motor, it provides the measurement capability for the fastest motor-drive troubleshooting.

Reporting and Analysis

Simplifies the process of gathering data and writing test reports with a built-in report generator. At each test point or measurement there is the option to create, update or modify a report. Simply press ‘SAVE TO REPORT’ and select the appropriate screens to save into a text based report file. By performing the step-by-step guided measurements a comprehensive report can be created directly from the instrument to document the entire troubleshooting process. Input the report name. The single report encompasses all recorded measurements and can easily be shared with other users and used for motor- drive benchmarking, and for comparing data now and in the future.



Applications:

  • Industrial automation
  • HVAC
  • Motor repair
  • Discrete or process based industrial manufacturing
  • Waste water treatment
  • Oil and gas maintenance

ISSWWW and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all important purchase.

DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 999 counts
Accuracy at 4 s to 10 us/div ±(3 % + 6 counts)
AC voltage (V ac)
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 999 counts
50 Hz ±(3 % + 10 counts) - 0.6 %
60 Hz ±(3 % + 10 counts) - 0.4 %
60 Hz to 20 kHz ±(4 % + 15 counts)
20 kHz to 1 MHz ±(6 % + 20 counts)
1 MHz to 25 MHz ±(10 % + 20 counts)
True-rms voltage (V ac+dc)
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 1100 counts
DC to 60 Hz ±(3 % + 10 counts)
60 Hz to 20 kHz ±(4 % + 15 counts)
20 kHz to 1 MHz ±(6 % + 20 counts)
1 MHz to 25 MHz ±(10 % + 20 counts)
PWM voltage (V pwm)
Purpose To measure on pulse width modulated signals, like motor drive inverter outputs
Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy As Vac+dc for sinewave signals
Peak voltage (V peak)
Modes Max peak, min peak, or pk-to-pk
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 10 mV
Accuracy
Max peak, min peak ±0.2 division
Pk-to-pk ±0.4 division
Full scale reading 800 counts
General Specification
Current (AMP) with current clamp
Ranges Same as V ac, Vac+dc or V peak
Scale Factors 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Accuracy Same as Vac, Vac+dc or V peak (add current clamp accuracy)
Frequency (Hz)
Range 1.000 Hz to 500 MHz
Full scale reading 999 counts
Accuracy ±(0.5 % + 2 counts)
Voltage/Herz ratio (V/Hz)
Purpose To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives
Accuracy % Vrms + % Hz
Voltage unbalance drive input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
Accuracy Indicative percentage based on Vac+dc values
Voltage unbalance drive output and motor input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages
Accuracy Indicative percentage based on V PWM values
Current unbalance drive input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values
Accuracy Indicative percentage based on Aac+dc values
Current unbalance drive output and motor input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values
Accuracy Indicative percentage based on A ac values
Rise and fall time
Readings Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot
Accuracy As oscilloscope accuracy
Harmonics and spectrum
Harmonics DC to 51st
Spectrum ranges 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation)
Shaft voltage
Events / second Indicative percentage based on rise and fall time (Impulse discharges) measurements
Report data capture
Number of screens Typical 50 screens can be saved in reports (depends on compression ratio)
Transfer to PC Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool
Probe settings
Voltage probe 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1
Current clamp 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Shaft voltage probe 1:1, 10:1, 100:1

Standard FREE 3-5 Day Courier Delivery – UK Mainland only - Zones A & B
Included in the price for all orders over £40.00 (exc vat). Sent using express courier, delivered within 3-5 working days from the date of your order, subject to availability.

Standard 1-2 Day Express Courier Delivery – UK Mainland only - Zones A & B
£4.50 for all all orders under £40.00 (exc vat). Sent by express courier, delivered within 1-2 working days from the date of your order, subject to availability.

Express Courier 1-2 Day Delivery – UK Mainland only - Zones A & B
£4.50 select at the checkout. Sent using express courier.

Next Day Delivery – UK Mainland only - Zones A & B
£8.00 select at the checkout. Sent using express courier, orders must be placed before 3pm for next day delivery, subject to availability.

Saturday Pre 12am - UK Mainland only - Zones A & B
£15.00 select at the checkout. Sent using express courier, orders must be placed before 3pm for Saturday delivery.

Orders must be placed before 3pm for next day delivery and a telephone number supplied, subject to availability.
Please note that predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope of our dispatch and therefore may incure additional days lead time to your order.

Orders requiring calibration. Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received late afternoon and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration. Be assured they will ship on the next dispatch, this in most cases should not add more than 24 hours to you delivery.

Delivery Surcharges
Because of the high cost of carriage we need to apply a surcharge on all deliveries made in the following regions bringing the carriage charges to:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands. 
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands.
  • Zone E - Northern Ireland
  • Zone F - Republic of Ireland

New Postage Map Sept 2018> 

International delivery

International delivery charges are automatically added to your order at the checkout; you can also use the guide below for a guide on prices. For any questions regarding international deliveries please contact us at sales@isswww.co.uk