Like most organisations we use cookies on our site, these allow us to improve your experience on our site, provides us with measurement and analytical data, and allows us to make use of the latest digital marketing capabilities - if you want to know more about cookies and how you can control them see our cookie policy here, if you are happy for us to use cookies then please click the button opposite.
The images provided are for illustrative purposes only. Please refer to product description.

Fluke 718Ex Intrinsically Safe Pressure Calibrator

The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a powerful, intrinsically safe, self contained pressure calibrator for usage in Explosion endangered areas.

Next Day Delivery (subject to availability)

£2,995.00 exc. VAT £3,594.00 inc. VAT £4,026.00 inc. VAT
  • 3 Ranges
  • Accuracy 0.05%
  • Intrinsically Safe
  • Min/Max function
  • Data hold function
  • High Accuracy and Performance
  • FreeDelivery
  • 30DayMoneyBack
Required Fields
  • Description
  • Features & Specification
  • Resources
  • Delivery

Fluke 718Ex Intrinsically Safe Pressure Calibrator

Available in 30G, 100G, and 300G Pressure Ratings

 

Potentially explosive atmospheres can be found in a variety of manufacturing environments from chemical or pharmaceutical processing, to oil refineries—or any environment where flammable material (gas or dust/particulates) are present. Fluke’s intrinsically safe test tools can be used to help you perform maintenance and calibration tasks in potentially explosive and hazardous classified areas. Fluke offers the widest range of reliable, accurate and intrinsically safe test tools. Including true-rms multimeters, infrared thermometers, process calibrators, pressure calibrators, loop calibrators and precision pressure test gauges.

The Fluke 718EX 300 Intrinsically Safe Pressure Calibrator measures pressure via a 1/8-Inch NPT pressure fitting and an internal pressure sensor or via Fluke 700PEX Series Pressure Modules. The calibrator simultaneously displays pressure and current measurements, performs switch testing and measures current up to 24 mA.

The calibrator's unit button selects a different pressure unit. All units are available when the pressure sensor input is used. The damp button turns pressure reading damping on and off. With damping on, the calibrator averages several measurements before displaying a reading. The Calibrator automatically turns off after 30 minutes of inactivity.

This equipment is specified for use in measurement category I (CAT I) pollution Degree 2 environments and should not be used in CAT II, CAT III, or CAT IV environments.-voltage transients should not exceed 300-volts for the CAT I applications where this product is used. Do not use in a damp or wet environment.

 

Fluke 718Ex Comes Supplied With:

  • Holster
  • 9-volt Alkaline Battery
  • Set of TL75 Test Leads
  • Set of AC72 Alligator Clips
  • Control Drawing and CD-Rom

 

Key Features:

  • ATEX II  1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.
 

 Fluke 718Ex is Available in the Folowing Formats:

718 Ex 30G -12 PSI to 30 PSI (-82.7 kPa to 207kPa) 0.001 PSI (0.01 kPa) 0.05% FS
718 Ex 100G -12 PSI to 100 PSI (-82.7 kPa to 690 kPa) 0.01 PSI (0.01 kPa) 0.05% FS
718 Ex 300G -12 PSI to 300 PSI (-82.7 kPa to 2068 kPa) 0.01 PSI (0.01 kPa) 0.05% FS

 

About Intrinsically Safe Products

Products that appear on this website that are listed as or relate to a classification of intrinsic safety are titled and described according to our best understanding and/or interpretation of the complex and sometimes changing criteria governing such classification as set out by the Health and Safety Executive.

Please note that due to the volatile nature of the intended use of products in this category,  neither UK Test Instruments or Instrument Sales and Service can be held responsible for any incident that arises from the purchase or use of any product described within this web site. For more information please visit the health and Safety Executive website with specific regard to Hazardous Area Classification and Control of Ignition Sources.


ISSWWW and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all important purchase.

Fluke 718Ex Intrinsically Safe Pressure Calibrator
Measurement Accuracy
Pressure
Fluke 718Ex 30G  
Range:  -830 mbar to 2 bar (internal sensor)
   Over pressure: 3x FS
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
   Note: for use with non-corrosive gasses
Fluke 718Ex 100G  
Range:  -830 mbar to 7 bar (internal sensor)
   Over pressure: 2x FS
Resolution:  0.001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
   Note: for use with non-corrosive gasses
Fluke 718Ex 300G  
Range:  -830 mbar to 20 bar (internal sensor)
   Over pressure: 375 psi, 25 bar
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
   Note: for use with non-corrosive gasses
Fluke 718Ex series  
   via pressure module connector
Range:  29 pressure modules, 2.5 mbar to 700 bar
   Over pressure per pressure module specs
Resolution:  Per pressure module specs
Accuracy:  To 0.025% of full span, per pressure module specs
Functions:  Zero, Min, Max, Hold, Damp
   Note: media compatibility per pressure module specs
Source Pressure, built in pump  
Range:  -820 mbar to full scale

 

Note:  Supported Pressure Units PSI, in. H2O (4 °C), in. H2O (20 °C), kPa, cm H2O (4 °C),
   cm H2O (20 °C), bar, mbar, kg/cm², mmHg, in Hg

 

Technical Data
Measure Accuracy:
Range:  0-24 mA
Resolution:  0.001 mA
Accuracy:  0.02% rdg ± 2 counts
Display
   LCD, 5 digit pressure and current simultaneous

 

Environmental Specifications
Operating Temperature
   -10ºC to 55ºC
Storage Temperature
   -40ºC to 60ºC
Humidity (Without Condensation)
   95% (10ºC to 30ºC)
   75% (30ºC to 40ºC)
   45% (40ºC to 50ºC)
   35% (50ºC to 55ºC)
Operating Altitude
   3,000 m max

 

Safety Specifications
Safety
   ATEX II  1G Ex ia IIC T4 compliant
   CSA Certification I.S. Class I,
   Div 1 Groups A-D , T4

 

Mechanical & General Specifications
Size
   216 mm L x 94 mm W x 66 mm H (with holster)
Weight
   Approx. 992 g (with holster)
Warranty
   Three years, one year for pump
Shock
   1 meter drop test
Vibration
   Random, 2 G, 5-500 Hz
Battery type
   One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
   Battery life: 4 to 20 hours, depending on functions used

 

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring
calibration may on occasion miss dispatch that day, according to the complexity of the calibration. Be assured they will ship on the next dispatch
this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope 
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.


*UK Mainland (Temporarily revised June 2020)

Please note that regrettably, we have had to realign our delivery service options to those available from our carriers.
During the current situation surrounding the effects of the Coronavirus pandemic, logistics from every company are under immense pressure to deliver goods on time.
We have taken the decision to temporarily limit our services rather than let our customers down.
We hope you will understand our position on this and we apologise unreservedly for the inconvenience we know this will cause.
We look forward to restoring our full delivery service schedule just as soon as we are able.

Standard FREE 1-2 Day Courier Delivery – UK Mainland only - Zones A & B

Included in the price for all orders over £75.00 (exc vat). Sent using express courier, delivered within 1-2 working days from the date of your order, subject to availability.

 

Next Day Anytime Delivery (Excluding Saturday & Sunday) – UK Mainland only - Zones A & B
Sent by express courier, delivered next day (excluding weekends) from the date of your order, subject to availability.

 

Orders must be placed before 3:00pm for a qualifying next day delivery and a telephone number supplied, subject to availability.

New Postage Map Sept 2018>

Delivery Surcharges

Because of the high cost of carriage, we need to apply a surcharge on all deliveries made in the following regions bringing the carriage charges to:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 2 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International Delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to purchase your items.
All stated prices are subject to VAT at the current rate where applicable E&OA