Seaward Apollo 600 Standard Kit

The Apollo 600 integrates PAT testing with risk assessment

Next Day Delivery (subject to availability)

£926.00 ( £1,111.20 including VAT @ 20%)

Regular Price: £1,729.20

  • Manufacturer Certificate Included
  • Entry level PAT kit
  • Pass and fail labels included
  • UKAS calibration included
  • 110V Adaptor Included
  • Free PATMobile app

Quick Overview

Part Numbers:
Standard Package = 380A910
Professional Package = 380A950



Earth Continuity

















Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined




Insulation Resistance

















Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined




IEC Lead Test













Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed




Protective Conductor Current/Load

















Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined




Touch Current

















Test Voltage Supply Voltage, maximum load current 16A
Display Ranges 0.00 – 3.50mA
Pass Value User defined




Load Power/Current

















Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A




Alternative Leakage Current

















Test Voltage >25Vac <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined




RCD Test





















Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms
Test method Internal isolation to avoid tripping distribution board RCD




Power Socket Test

























Voltage Range 207V – 253Vac
Indicates configuration of voltage potential:-  
Line potential phase to earth  
Line potential phase to neutral  
Line potential neutral to earth  




General





















Memory size 50,000 records & 2,000 photos
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack




Standard Accessories (supplied with Apollo 600)
































Apollo checkbox
2x test leads and probes with crocodile clips
0.5m IEC lead
110V test adaptor
Mains power lead
USB download cable
30 day free trial of PATGuard 3 Health and Safety Edition
Quick start guide
Carry case




Optional Accessories

















Test n Tag Elite bluetooth printer
Bluetooth barcode scanner
TPA Series 3-Phase leakage adaptor
PATGuard 3 software

* Required Fields

£926.00 ( £1,111.20 including VAT @ 20%)

Regular Price: £1,729.20

Additional Information

Key Features Manufacturer Certificate Included, Entry level PAT kit, Pass and fail labels included, UKAS calibration included, 110V Adaptor Included, Free PATMobile app
Product Tagline The Apollo 600 integrates PAT testing with risk assessment
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Seaward
Features/Specification

Part Numbers:
Standard Package = 380A910
Professional Package = 380A950

Earth Continuity

Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined


Insulation Resistance

Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined


IEC Lead Test

Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed


Protective Conductor Current/Load

Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined


Touch Current

Test Voltage Supply Voltage, maximum load current 16A
Display Ranges 0.00 – 3.50mA
Pass Value User defined


Load Power/Current

Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A


Alternative Leakage Current

Test Voltage >25Vac <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined


RCD Test

Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms
Test method Internal isolation to avoid tripping distribution board RCD


Power Socket Test

Voltage Range 207V – 253Vac
Indicates configuration of voltage potential:-  
Line potential phase to earth  
Line potential phase to neutral  
Line potential neutral to earth  


General

Memory size 50,000 records & 2,000 photos
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack


Standard Accessories (supplied with Apollo 600)

Apollo checkbox
2x test leads and probes with crocodile clips
0.5m IEC lead
110V test adaptor
Mains power lead
USB download cable
30 day free trial of PATGuard 3 Health and Safety Edition
Quick start guide
Carry case


Optional Accessories

Test n Tag Elite bluetooth printer
Bluetooth barcode scanner
TPA Series 3-Phase leakage adaptor
PATGuard 3 software
Fluke Price Banner No

With built-in risk assessment tools for any workplace hazard and a variety of testing and inspection reports including portable appliance testing, fire detection and alarms and emergency lighting; Apollo 600 offers an all-in-one solution to managing a risk-based approach to health and safety in any workplace, reducing the burden and ensuring compliance. The Apollo 600 is the perfect solution for those looking to upgrade from the PrimeTest 350.

Keep comprehensive client records including test and inspection reports, risk assessments and visual evidence with the help of Seaward’s PATGuard 3 Health and Safety Edition software.

Key Features

  • Supreme PAT testing capability
  • On-board camera with flash for visual evidence
  • Built in risk assessment tools
  • USB and Bluetooth data transfer
  • High definition colour display
  • Point to point testing for fixed appliances
  • Store 2,000 images and 50,000 appliance records
  • Health and safety test and inspection forms including emergency lighting

What's in the box?

The Apollo 600 is supplied as standard with:

- Apollo checkbox
- 2x test leads and probes with crocodile clips
- 0.5m IEC lead
- 110V test adaptor
- Mains power lead
- USB download cable
- 30 day free trial of PATGuard 3 software
- Quick start guide
- Carry Case
- UKAS calibration certificate
- 2 year warranty (subject to product registration)

Available Kits

Apollo 600 comes with an accessory kit as standard, which includes everything you need to get started.

 

  Standard Pro
Apollo 600 Y Y
Free trial of PATGuard 3 Health and Safety Edition software Y Y
2 x test leads with test probes and clips Y Y
IEC lead Y Y
110V adaptor Y Y
Apollo 600 PAT checkbox Y Y
USB download lead Y Y
Mains power lead Y Y
Quick Start Guide Y Y
Support CD-Rom including full user manual Y Y
Apollo 600 carry case Y Y
Carry case for Bluetooth accessories   Y
Bluetooth printer   Y
Bluetooth barcode scanner   Y

 

 

 

Part Numbers:
Standard Package = 380A910
Professional Package = 380A950

Earth Continuity

Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined


Insulation Resistance

Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined


IEC Lead Test

Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed


Protective Conductor Current/Load

Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined


Touch Current

Test Voltage Supply Voltage, maximum load current 16A
Display Ranges 0.00 – 3.50mA
Pass Value User defined


Load Power/Current

Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A


Alternative Leakage Current

Test Voltage >25Vac <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined


RCD Test

Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms
Test method Internal isolation to avoid tripping distribution board RCD


Power Socket Test

Voltage Range 207V – 253Vac
Indicates configuration of voltage potential:-  
Line potential phase to earth  
Line potential phase to neutral  
Line potential neutral to earth  


General

Memory size 50,000 records & 2,000 photos
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack


Standard Accessories (supplied with Apollo 600)

Apollo checkbox
2x test leads and probes with crocodile clips
0.5m IEC lead
110V test adaptor
Mains power lead
USB download cable
30 day free trial of PATGuard 3 Health and Safety Edition
Quick start guide
Carry case


Optional Accessories

Test n Tag Elite bluetooth printer
Bluetooth barcode scanner
TPA Series 3-Phase leakage adaptor
PATGuard 3 software
  • There are no files associated with this product. For more information please call 0800 0224 060

Standard Free Delivery 3-5 Day Delivery – UK Mainland only - Zone A & B
Included in the price for all orders. Sent using UK Mail, delivered within 3/5 working days from the date of your order, subject to availability.

Express DPD Delivery 1-2 Day Delivery – UK Mainland only - Zone A & B
£4.50 select at the checkout. Sent using DPD on their Award Winning “Predict” Service with these great key benefits:

  • You are given a one hour delivery window. (no more waiting in all day for your parcel)
  • You are notified by text or e-mail on your parcels progress.
  • Change of plan? You can easily use the text or e-mail to rearrange your delivery.
  • Notifications on your parcel up to 15 minutes before delivery.

Orders must be placed before 3pm for next day delivery and a mobile number supplied, subject to availability.

Next Day Delivery – UK Mainland only - Zone A & B
£8.00 select at the checkout. Sent using UK Mail, orders must be placed before 3pm for next day delivery, subject to availability.

Saturday Pre 12am - UK Mainland only - Zone A & B
£15.00 select at the checkout. Sent using UK Mail, orders must be placed before 3pm for Saturday delivery.

Delivery Surcharges
Because of the high cost of carriage we need to apply a surcharge on all deliveries made in the following regions: 

  • Scotland, Isle of Wight & Isles of Scilly - £6.00  
  • Scottish Highlands and Northern Ireland - £12.00  Zone C
  • Scottish Islands, Isle of Man and Channel Islands - £14.00  Zone D
  • Southern Island - £15.00  Zone E

 

 International delivery

International delivery charges are automatically added to your order at the checkout; you can also use the guide below for a guide on prices. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

 Zone 1:

  • France, Germany, Belgium, Netherlands, Luxembourg. £20.00 per parcel

Zone 2:

  • Austria, Denmark. £22.00 per parcel
  • Liechtenstein, Switzerland £47.00 per parcel (added cost for custom clearance surcharge)

Zone 3:

  • Czech Republic, Italy, Slovakia, Spain. £28.00 per parcel

Zone 4:

  • Estonia, Finland, Hungary, Poland, Portugal, Slovenia, Sweden. £50.00 per parcel

Zone 5:

  • Bulgaria, Croatia, Greece (incl islands) Latvia, Lithuania, Romania. £60.00 per parcel

Bosnia-Herzegovina, Iceland, Norway, Serbia. £85.00 per (added cost for custom clearance surcharge)

If no shipping option is available to your selected country.  Please call us on +44 (0) 1603 406 148 to purchase your items.

You may also be interested in the following product(s)