Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

With a full range of AC/DC current, AC/DC voltage, and frequency measurement functions for basic electrical troubleshooting, the AMP-220 clamp meter with its large backlit display is an excellent amp clamp meter choice. Rated CAT III 600 V, the AMP-210 clamp meter offers True-RMS sensing, fast response processor, non-contact voltage detection, capacitance, resistance and continuity measurements to enhance efficiency and safety in today’s complex electrical environments.

AMP-220 600A AC/DC TRMS Clamp Meter

  • True-RMS
  • Voltage up to 600 V AC/DC, Current up to 600 A AC/DC, resistance and frequency
  • Low pass filter for variable frequency drives
  • Amp-tip function for precise low current measurements down to the tenth of an Amp
  • Capacitance measurement for start and run motor capacitors
  • Non-contact voltage detection
  • Audible continuity and diode test
  • Data hold, relative zero
  • Large LCD backlit display
  • Accommodates conductors up to 1.37 in (35mm)
  • CAT III 600 V safety rated

Included Accessories: Test Leads, (2) AAA Batteries (installed), User Manual, Carrying Case

The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, enabling accurate current measurement of both large and small diameter wires. A low pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency).

  • Measures AC/DC Current to 600 A and AC/DC Voltage to 600 V
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Capacitance measurement, continuity beeper and diode test
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Offers data hold and relative zero for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • Backlit display for easy measurement viewing in bright and dim environments
  • Accommodates conductors up to 1.37 in (35mm)
  • Includes test leads, batteries (installed), carrying case, and user manual
  • CAT III 600 V safety rated
FEATURE AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
AC voltage (True-rms) Range: 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz) ±0.8% + 5LSD (50 to 60 Hz)
DC voltage Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
AC+DC voltage Range: 0 to 600.0 V 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.2% + 7LSD (50 to 60 Hz) ±1.2% + 7LSD (50 to 60 Hz) ±1.0% + 7LSD (50 to 60 Hz) 
±1.8% + 7LSD (DC 40 to 200 Hz) 
±1.2% + 7LSD 200 to 400 Hz)
AC current Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (100 to 400 Hz)
DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.0% + 5LSD (DC 50 to 100 Hz) ±2.0% + 5LSD (DC 50 to 100 Hz) ±1.8% + 5LSD (DC 50 to 100 Hz)
AC+DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (40 to 100 Hz) 
±2.5% + 7LSD (100 to 400 Hz)
Precise low current AC Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)
Precise low current DC Range: 0 to 60.0 A 0 to 60.0 A 0 to 60.00 A
Accuracy: ±2.0% + 5LSD ±2.0% + 5LSD ±1.5% + 5LSD (0.00 to 20.00 A) 
±3.0% + 5LSD (>20.00 to 60.00 A)
Micro amps Range: 0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Frequency Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±2.0% + 4LSD (600 A range)
Resistance Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity beeper ON ≤ 10 Ω
Off > 250 Ω
Temperature* 
(Type K thermocouple)
  -40.0 to 752 °F
-40.0 to 400 °C
  ±1.0% + 3.0 °F (-40.0 to 14.0 °F) 
±1.0% + 1.5 °F (>40.0 to 99.9 °F) 
±1.0% + 2.0 °F (100 to 752 °F) 
±1.0% + 1.5 °C (-40.0 to 10.0 °C) 
±1.0% + 0.8 °C (>-10.0 to 99.9 °C) 
±1.0% + 1.0 °C (100 to 400 °C) 
Non-contact voltage 10 V to 1000 V AC (50 to 60 Hz)
Phase rotation indication   Rotation-R for main supply 
Rotation-M for motors
Diode test  
Jaw opening   1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Safty rating   CAT III 600 V CAT IV 600V 
CAT III 1000 V
Special Features
In-rush current  
Peak hold (Crest)  
Relative zero  
Max/Min/Avg  
Data hold  
Backlight  
Auto power off  
Work light  

*Error does not include Type-K thermocouple errors

For complete specs please download the product datasheet under the "Resources" tab.

Standard Delivery 3-5 Day Delivery – UK
£2.95 for all all orders under £40.00 (exld vat). Sent by Royal Mail Tracked, delivered/posted within 3-5 working days from the date of your order, subject to availability.

Standard Free Delivery 3-5 Day Delivery – UK Mainland only - Zone A & B
Included in the price for all orders over £40.00 (exld vat). Sent using FedEx, delivered within 3-5 working days from the date of your order, subject to availability.

Express DPD Delivery 1-2 Day Delivery – UK Mainland only - Zone A & B
£4.50 select at the checkout. Sent using DPD on their Award Winning “Predict” Service with these great key benefits:

  • You are given a one hour delivery window. (no more waiting in all day for your parcel)
  • You are notified by text or e-mail on your parcels progress.
  • Change of plan? You can easily use the text or e-mail to rearrange your delivery.
  • Notifications on your parcel up to 15 minutes before delivery.

Orders must be placed before 3pm for next day delivery and a mobile number supplied, subject to availability.

Next Day Delivery – UK Mainland only - Zone A & B
£8.00 select at the checkout. Sent using FedEx, orders must be placed before 3pm for next day delivery, subject to availability.

Saturday Pre 12am - UK Mainland only - Zone A & B
£15.00 select at the checkout. Sent using FedEx, orders must be placed before 3pm for Saturday delivery.

Delivery Surcharges
Because of the high cost of carriage we need to apply a surcharge on all deliveries made in the following regions: 

  • Scotland, Isle of Wight & Isles of Scilly - £6.00  
  • Scottish Highlands and Northern Ireland - £12.00  Zone C
  • Scottish Islands, Isle of Man and Channel Islands - £14.00  Zone D
  • Southern Island - £15.00  Zone E

 

 International delivery

International delivery charges are automatically added to your order at the checkout; you can also use the guide below for a guide on prices. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

 Zone 1:

  • France, Germany, Belgium, Netherlands, Luxembourg. £20.00 per parcel

Zone 2:

  • Austria, Denmark. £22.00 per parcel
  • Liechtenstein, Switzerland £47.00 per parcel (added cost for custom clearance surcharge)

Zone 3:

  • Czech Republic, Italy, Slovakia, Spain. £28.00 per parcel

Zone 4:

  • Estonia, Finland, Hungary, Poland, Portugal, Slovenia, Sweden. £50.00 per parcel

Zone 5:

  • Bulgaria, Croatia, Greece (incl islands) Latvia, Lithuania, Romania. £60.00 per parcel

Bosnia-Herzegovina, Iceland, Norway, Serbia. £85.00 per (added cost for custom clearance surcharge)

If no shipping option is available to your selected country.  Please call us on +44 (0) 1603 406 148 to purchase your items.